SaveTime & Savetime Lite Setup and Test, pages 10 to 18

Pages 10 to 18 of 41

The original document is the PDF (181 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the CMI SaveTime Series 2000

Page 10

Setup and Test / 1.8

Using the Setup Mode Use the Setup mode when you are installing or swapping terminals and want to choose values for the parameters the terminal uses. The following table lists all the parameters and the values you can choose for them. Parameter

Values

Baud Rate Parity Host Delay Terminal Address Reader Type

12ØØ, 24ØØ, 48ØØ, 96ØØ, 192ØØ Odd, Even, Mark, Space,None (effective PS250-Ø11F) Ø 9 (1 - 9Ø mS) ØØ 31 Barcode, Mag I, Mag II, Wiegand,Holonetic, Barcode/Holonetic, Mag1/Holonetic,Mag 2/Holonetic, Wiegand/Holonetic, Bioscan

The parameters are stored in NOVRAM so they stay in the terminal even if you turn the power off until you change them. Data transmitted by the terminal and host computer is always ten bits in length and follows the format: one start bit, seven data bits, one parity bit, and one stop bit.

Default Parameters When you receive your terminal, it will already be set up with these values: Baud rate Parity Host Communication delay Terminal address Reader

192 ØØ O (odd) HD Ø (1 mS---cluster mode) ØØ

Barcode

Usually, all you have to do is assign a different terminal address from ØØ to 31 to each terminal. When more than one terminal is connected to the same network or communications line, each terminal must have a unique address so it can communicate with the host computer. You can assign a maximum of 32 terminals to each network.

Choosing Values for Parameters To choose values for a terminal's parameters, you use one of two methods: • Scan an INIT label • Use the keyboard Scanning an INIT label lets you to automatically set all the values for the parameters at once. Using the keyboard gives you the chance to access each individual parameter and then select a value for that parameter.

Control Module Inc.

2016 Setup

Page 11

Setup and Test / 1.9

Scanning an INIT Label When you need to set up a terminal’s parameters quickly, use a wand to scan an INIT label or read a badge containing an INIT label. An INIT label is a bar code containing a parameter list for a specific terminal.

I NI T 1 1 9 OJ C 0 0

Sample INIT Label

As the following sequence shows, after you scan the INIT label, the terminal acknowledges your scan and shows the new values you just entered for the terminal parameters

Using the INIT Label 1. Move the On line/Off Line switch to the Off line position. After briefly showing several informational messages the terminal will display: ↑↓E H

Setup Mode? INIT 19,O,HDØ,AØØ,BC

2. The INIT in the display line indicates an INIT label is a valid input at this point. Scan an INIT label now. This is indicated by the Q in the bottom right of the display. 3. The display briefly shows: INITIALIZED

4. Then the updated parameters are shown: ↑↓E H

Setup Mode? INIT 19,O,HDØ,AØØ,BC

Note: The display above is an example of what you will see. The values will vary to reflect what’s actually on the INIT label. Now you can do one of the following:

1. Go to another mode Press the ↑ or ↓ key until to see the selection you want. 2. Exit the Off line mode Move the On line / Off line switch to the On line position.

Control Module Inc.

2016 Setup

Page 12

Setup and Test / 1.10

Keyboard Besides using the wand or slot reader to scan an INIT label, you can also change a terminal's parameters by using the keyboard. Power up the Savetime terminal and hold the C and E keys. After a few transient messages are displayed you will see the following screen: Setup Mode? INIT 19,O,HDØ,AØØ,BC

↑↓E

The second line, “19,O,HDØ,AØØ,BC” shows the values currently assigned to the terminal's parameters. The respective parameters are baud rate, parity, turnaround delay, address, and reader type. To change any of these values: Press the ENTER key to enter the parameter editor. The screen changes to show: Baud Rate 19,O,HDØ,AØØ,BC

← → ↑↓ H

The terminal highlights the currently selected parameter in the lower line of the display with an underline cursor. The upper line shows the selected parameter’s name in the left side and lists the valid keys in the right side. The valid keys may change depending on the selected parameter. As an example, to change a terminal address-----Press the → key three times until the display shows: Address 19,O,HDØ,AØØ,BC

#C← → ↑ ↓H

Now, you have several options for setting the address. You can directly enter the address using the numeric keypad (#) or reset it to 0 using the CLEAR key (C). Alternately, you can use the ↑↓ keys to increment or decrement the address. If you hold the arrow key down it will start to autorepeat. Once you’ve set the address, you can move to another parameter using the ← → keys. Press the HOME key (H) to exit the parameter editor or move the On line/Off Line switch to the On line position to leave Off line Mode. Either of these actions updates the stored parameters.

Control Module Inc.

2016 Setup

Page 13

2016 Setup Utility Mode / 2.1

Using the Utilities Mode: Use ↑↓ to view the Utilities, press E to enter a specific utility, press H for the setup menu . Modem Utility

General modem check-out utility. UTILITIES Modem Utilities?

↑↓ H

Press E to enter the Utility MODEM UTILITIES Switch to On line

H

Locate the ‘ON LINE/OFF LINE’ switch on your communications module and place it in the OFF LINE position. Hit H to escape. The display will show the following: Checking for modem .

If the modem is not found you will get the following message: Modem not found !

If the modem is found, you will get this message: Modem initialized!

MODEM UTILITIES Initialize Modem?

H

At this point the modem is verified as functional, initialized and ready to use. If you press E, the modem will be initialized again. Press H to return to setup or move the ‘ON LINE/OFF LINE’ switch on the communications module to the ‘ON LINE’ position to exit Off line mode.

Control Module Inc.

2016 Setup Utilities

Page 14

2016 Setup Utility Mode / 2.2

Using the Utilities Mode: Use ↑↓ to view the Utilities, press ENTER to enter a specific utility, press HOME for the setup menu. Wiegand analysis

Examine the binary information encoded within the badge UTILITIES Wiegand analysis?

↑↓ H

Press E to enter the Utility READ BADGE…

Swipe the wiegand or proximity badge through the reader or press HOME. 26 BITS 11ØØ111 Ø11Ø1ØØ1ØØ1ØØ1ØØ1Ø1 The bit number is the length of the binary data found on your card The binary data found on the badge is displayed. READ BADGE…

H

Swipe another badge or press HOME to for the setup menu.

Control Module Inc.

2016 Setup Utilities

Page 15

2016 Setup Utility Mode / 2.3

Using the Utilities Mode: Use ↑↓ to view the Utilities, press ENTERto enter a specific utility, press HOMEfor the setup menu. Bar-code analysis

Examine the bar-code information encodes on the badge. ↑↓ E H

UTILITIES Barcode analysis? Press ENTER to enter the Utility READ BADGE…

H

Swipe your barcode badge through the reader or wand the barcode or press HOME to exit. CODE: 39 123456 The code number is your type of barcode found The characters displayed are what was found on the badge READ BADGE…

H

Swipe another badge or press HOME to for the setup menu. (Note: I2of5 badges have specific lengths, use badges with length of 6 -12 for testing)

Control Module Inc.

2016 Setup Utilities

Page 16

2016 Setup Utility Mode / 2.4

Using the Utilities Mode: Use ↑↓ to view the Utilities, press ENTERto enter a specific utility, press HOMEfor the setup menu. ( IF YOU ARE USING AØ52-XXX 2 MODULE , YOU MUST REMOVE IT WHILE SETTING THE LINC MODULE.) ( REMOVE POWER BEFORE REMOVING OR INSERTING THE Ø52 2 MODULE ) ( IF YOU HAVE AN EXTERNAL READER PLUGGED INTO THE LINC WAND MONITOR PORT, IT WILL BLOCK COMMUNICATIONS IF PIN 1 IF GROUNDED IN THE READER. UNPLUG THE READER DURING SETUP)

Ethernet Utility

General ethernet setup utility. ↑↓ E H

UTILITIES Ethernet Utilities?

Press ENTER to enter the Utility or H to escape. The terminal will now display that is is searching for a LINC module: You will see the RXD and TXD flash on the LINC module. READING LINC MODULE

If the LINC module is not found, you will get this message: Older LINC modules can not be detected from the setup menu and must be changed with TELNET or the serial wand cable. LINC NOT DETECTED

If the LINC module is found, you will get this message: TERMINAL IP 192.168.ØØØ.062

# C E ↑↓ E H

To change the IP address, use the keypad to type in a new value, or use the ↑ ↓ Use the ← → arrows to move between the IP octets. TERMINAL IP 192.168.ØØØ.062

# C E ↑↓ E H

Press ENTER when you are done typing in the IP address To change the TERMINAL PORT use the keypad to type in a new value, or use the ↑ ↓ Use the ← → arrows to move between the digits. TERMINAL PORT Ø3ØØ1

# C E ↑↓ E H

Press ENTER when you are done typing in the TERMINAL PORT

Control Module Inc.

2016 Setup Utilities

Page 17

2016 Setup Utility Mode / 2.5 Setting up the SUB NET MASK or HOST BITS SUB NET MASK SETUP If your Terminal shows SUBNET MASK instead of HOST BITS, then set as required, else skip this section. or use the ↑ ↓ U se the ← → arrows to move between the IP octets. Subnet Mask 255.255.255. ØØØ

# C E ↑↓ E H

Press E when you are done typing in the Subnet Mask, or C to clear, or H to escape.

If Your Terminal shows Host Bits, this is what you need to set it, else skip this section. HOST BITS SETUP The Host IP address must be within the IP address subnet mask of the LINC module or the host will not be able to communicate with it. It can Ping it but if you can not get into the setup menu at port 9999 with telnet, the subnet mask is incorrect. To change the HOST BITS, use the keypad to type in a new value, or use the ↑ ↓ Use the ← → arrows to move between the digits. The host bits define the subnet mask. 08=255.255.255.0 16=255.255.0.0 # C E ↑↓ E H

HOST BITS Ø8

Press ENTER when you are done typing in the HOST BITS. HOST BITS Values Ø8=255.255.255. Ø Ø 9=255.255.254. Ø 10=255.255.252. Ø 11=255.255.248. Ø 12=255.255.24 Ø .Ø 13=255.255.224. Ø 14=255.255.192. Ø 15=255.255.128. Ø

16=255.255. Ø.Ø 17=255.254. Ø.Ø 18=255.252. Ø.Ø 19=255.248. Ø.Ø 20=255.24 Ø .Ø.Ø 21=255.224. Ø.Ø 22=255.192. Ø.Ø 23=255.128. Ø.Ø

24=255.Ø.Ø .Ø 25=254. Ø.Ø .Ø 26=252. Ø.Ø .Ø 27=248. Ø.Ø .Ø 28=24 Ø .Ø.Ø .Ø 29=224. Ø.Ø .Ø 30=192. Ø.Ø .Ø 31=128. Ø.Ø .Ø 32= Ø .Ø.Ø .Ø

For example, if the HOST is at IP address 192.168.Ø .3 and the LINC module is as 192.170 .Ø .1 Both use 192 for the first octet. So 255 is ok. Allow Addresses 192-192, allow no other addresses in the first octet. The second octets are 168 and 17 Ø . Select the next value less than the lowest IP address shown from the table above. Second octet values are 255,254,248,24Ø ,224,192,128. This is 128. Allow addresses 128 –255 which covers 168 and 17Ø 0 for the second octet. The third octet is Ø .

Allow addresses from ØØØ -255 (we cant filter any further)

The fourth octet is Ø . Allow addresses from ØØØ -255 (we cant filter any further) This gives us 255.128. Ø . Ø or a HOST BITS value of 23.

Control Module Inc.

2016 Setup Utilities

Page 18

2016 Setup Utility Mode / 2.6

To change the GATEWAY IP address, use the keypad to type in a new value, or use the ↑ ↓ Use the ← → arrows to move between the IP octets. GATEWAY IP ØØØ. ØØØ. ØØØ. ØØØ

# C E ↑↓ E H

Press ENTER when you are done typing in the HOST IP address. Enter 000.000.000.000 if you have not Gateway. To change the HOST IP address, use the keypad to type in a new value, or use the ↑ ↓ Use the ← → arrows to move between the IP octets. HOST IP 192.168. ØØØ. Ø62

# C E ↑↓ E H

Press ENTER when you are done typing in the HOST IP address. Do not change this value. To change the HOST PORT, use the keypad to type in a new value, or use the ↑ ↓ Use the ← → arrows to move between the IP octets. # C E ↑↓ E H

HOST PORT Ø3ØØ1

Press ENTER when you are done typing in the HOST PORT. Do not change this value. To change TCP/UDP MODE, use the ↑ ↓ to select a mode. TCP / UDP Mode TCP

↑↓ H

Press ENTER when you are done typing in the TCP/UDP MODE . TCP is for Ethernet ↑↓ H

Flush Mode Standard

The flush mode should be set to standard if the menu offers it.

To update the LINC module with these changes, press ENTER. To disregard the changes, press CLEAR,

Control Module Inc.

2016 Setup Utilities