Page 1
SaveTime & Savetime Lite
Setup and Test
Revision 1. 0/ June 1, 20/ 01 /
Control Module, Inc. 227 Brainard Road Enfield, Connecticut 06082
Control Module Inc.2000
APPBUILDER
Cover
Page 2
TABLE OF CONTENTS 1. Setup Mode ................................ ................................ ................................ ........ 1-1 Self-diagnostics................................ ................................ ........................... 1-2 If Self-diagnostics Pass ................................ ................................ ............... 1-2 Model, Copyright, BIOS Version, Flash Version ................................ ............. 1-3 If Self-diagnostics Fail................................ ................................ .................. 1-4 CPU RAM Failure Message ................................ ................................ .... 1-4 PROM Failure Message ................................ ................................ ......... 1-4 RAM Failure Messages ................................ ................................ .......... 1-4 NOVRAM Failure Messages ................................ ................................ ... 1-4 RTC Failure Message................................ ................................ ............ 1-4 Invalid RAM Configuration Failure Message................................ ............ 1-4 Introducing the Test Mode ................................ ................................ ............ 1-5 Starting the Test Mode ................................ ................................ ................. 1-5 Using the Test Mode ................................ ................................ .................... 1-6 How to Use the CLEAR and ENTER Keys ................................ ..................... 1-6 Modes ................................ ................................ ................................ ....... .1-7 Q on display ................................ ................................ .............................. 1-8 Using the Setup Mode ................................ ................................ .................. 1.8 Scanning an Init label to setup the terminal ................................ ................... 1.9 Keyboard ................................ ................................ ................................ .. 1-10 2. Utility Mode ................................ ................................ ................................ ........ 2-1 Modem Utility ................................ ................................ ............................. 2-1 Weigand Analysis (checking Proximity or Wiegand badges) .......................... 2-2 Bar-code Analysis ................................ ................................ ....................... 2-3 Ethernet Utility ................................ ................................ ............................. 2-4 Subnet and Host bits ................................ ................................ ................. 2-5 RF Utilities ................................ ................................ ................................ .. 2-7 Biometric Utiliities ................................ ................................ ........................ 2-9 ID Utiliities................................ ................................ ................................ . 2-10 3. Diagnostics................................ ................................ ................................ ........ 3-1 Failure Messages ................................ ................................ ........................ 3-1 Monitoring the Voltage of a Terminal ................................ ............................. 3-2 Checking the Basic Functions of a Terminal ................................ .................. 3-3 Display and Beeper................................ ................................ ...................... 3-3 Communication Circuitry ................................ ................................ .............. 3-3 Keyboard, Wand, or Slot Reader ................................ ................................ .. 3-4 Practice Using the Keyboard, Wand, or Slot Reader ................................ ...... 3-5 Troubleshooting................................ ................................ ........................... 3-6 Running the Network Test ................................ ................................ ............ 3-7 Running the Automatic Test ................................ ................................ ......... 3-9 Restart Mode (Clear Ram)................................ ................................ ............ 3-11 4. Loader Mode ................................ ................................ ................................ ...... 4-1 Setup Mode................................ ................................ ................................ . 4-1 APP Mode ................................ ................................ ................................ ... 4-2
Control Module Inc.2000
APPBUILDER
TOC
Page 3
Setup and Test / 1.1
2Ø15 / 2Ø16 (2x2Ø, 2x24, 2X4Ø, 4x2Ø Displays) Setup Mode CMI data collection terminals have two diagnostic tools that ensure their reliable operation and aid in troubleshooting the terminal. Self-diagnostics is a series of tests run by the terminal itself. Off line Mode gives you access to several other modes that let you check the functions of the terminal. Setup Mode is one of the main modes you can access from within Off line Mode. It lets you set the terminal’s parameters that control things like communications and card readers.
Self-diagnostics Self-diagnostics let you know a terminal is malfunctioning so you don't have to perform additional diagnostics in the Off line Mode. When a terminal performs self-diagnostics, it checks: • CPU • ROM • RAM • FLASH • NOVRAM • RTC • COMMUNICATION INTERFACE (Off Line Mode only) If any of the parts above fail the self-diagnostics, the terminal's display shows a failure message. A terminal performs self-diagnostics each time you: • Apply power • Exit Off line Mode by moving the On line/Off line switch from the On line position to the Off line position.
Control Module Inc.
2016 Setup
Page 4
Setup and Test / 1.2
If Self-diagnostics Pass If self-diagnostics pass, the display shows different messages depending on whether the terminal is in the On Line or Off line mode.
In On line Mode If all tests pass in the One line mode, the display shows one of the following: LOCKED BY HOST! COMM OK
LOCKED BY HOST! NO COMM
LOCKED BY HOST! CONT
LOCKED, DOWNLOAD ERROR! COMM OK
LOCKED, DOWNLOAD ERROR! NO COMM
LOCKED, DOWNLOAD ERROR! CONT
LOCKED, NO DOWNLOAD! COMM OK
LOCKED, NO DOWNLOAD! COMM OK
LOCKED, NO DOWNLOAD! CONT
When the terminal is in locked mode, communications status is also displayed. If the terminal is in communications with the host you will see the message ‘COMM OK’. If the host has not polled the terminal in the past 20 seconds, the terminal will display ‘NO COMM’. When the terminal is in contention mode and a Lock command is given, the terminal will display ‘CONT’.
Control Module Inc.
2016 Setup
Page 5
Setup and Test / 1.3
In Off line Mode If all tests pass in the Off line Mode, the terminal displays several informational messages and shows its setup parameters. Each of the following messages display for about two seconds:
Model Information The terminal’s model name and number. CMI SaveTime 2ØØØ
Copyright Information The legal statement giving CMI control over the reproduction of the terminal. (C) CMI ‘2ØØØ
BIOS Firmware Version of Terminal BIOS program number and revision. “X” represents the single letter identifying the software version. BIOS: PSØØ272B
Application Software Version of Terminal Application program number and revision and data of release. PSØØ25-Ø11F Ø6/Ø1/Ø1
Control Module Inc.
2016 Setup
Page 6
Setup and Test / 1.4
If Self-diagnostics Fail If any parts fail the self-diagnostics, the display shows each failure message for about one second in the sequence listed below. The last failure message stays in the display. To re-display the failure messages press any key.
CPU RAM Failure Message CPU MEM FAILED
RAM Failure Messages BANK 1 FAILED
BANK 2 FAILED
BANK 1 & 2 FAILED
NOVRAM Failure Messages NOVRAM FAILED
SETUP REQUIRED !!
RTC Failure Message RTC FAILED
Control Module Inc.
2016 Setup
Page 7
Setup and Test / 1.5
Off Line Mode Off line Mode lets you to perform the following functions with a terminal: • Set up its communication parameters and select the reader type • Verify the keypad and reader are functional • Perform diagnostics • Utilities • Clear RAM ( data and download ) • Terminate APP ( erase the flash firmware ) • Exit Off line Mode A terminal in “off-line” is physically disconnected from the communications network. Any functions you perform do not affect the rest of the system.
Starting Off line Mode To place the terminal into Off line Mode:
1. Unlock the terminal by turning the key counterclockwise. 2. Remove the top of the terminal from the wall mount. Move the On line/Off line switch to the Off line position.
3. The display will briefly show several informational messages and will then display the following message: Setup Mode? INIT 19,O,HDØ,AØØ,BC
↑↓ E
This is the prompt for Setup Mode, the first selection in Off line Mode. The lower line lists the current parameter values.
Control Module Inc.
2016 Setup
Page 8
Setup and Test / 1.6
Using Off line Mode Once you are in Off line Mode, you can immediately go into Setup Mode to change the terminal’s operating parameters or you can select from a number of other modes. The first mode presented in Off line Mode is Setup Mode. Moving up or down, you can access each of the other modes by using the HOME, UP, DOWN, LEFT, RIGHT keys.
Valid Keys and Inputs When selecting from the modes available from within Off line Mode or when moving through Setup Mode, Quick Check Mode, and the other modes, different keys and inputs are valid at different stages. The rightmost field in the display’s upper line always shows a list of valid inputs. These values may change as you step through the different modes. The display always shows you a list of currently valid choices. The meaning and function of the input designators follows: I
Initialization label or badge Lets you set all values for all parameters at once.
↑
Up arrow key Moves to the next menu selection or next parameter value.
↓
Down arrow key Moves to the previous menu selection or previous parameter value.
→
Right arrow key Moves to the next parameter selection.
←
Left arrow key Moves to the previous parameter selection.
ENTER
ENTER Accepts the current selection.
CLEAR
CLEAR Cancels the current selection or operation.
HOME
#
HOME Returns control to the initial “Setup Mode?” screen. Signifies a numeric value can be entered directly via the number keys.
Control Module Inc.
2016 Setup
Page 9
Setup and Test / 1.7
Modes When you place the terminal into Off line Mode, it goes through an initial sequence where it presents several informational messages. Then it prompts the user for entry into Setup Mode. Setup Mode is the first in a list of selections. To go to the next choice you press the ↑ key. To go the previous choice press the ↓ key. Once you see the mode you want, press E (ENTER) to select it.
Setup Mode Set terminal parameters for communications and reader type. ↑↓ E
Setup Mode? INIT 19,O,HDØ,AØØ,BC
Q
Terminal has transactions in the queue.
The Q in the lower right corner or the terminal indicates there are transactions in the Queue of the terminal. Quick Check Mode
General terminal check-out utility. ↑↓E H
Quick Check?
Diagnostics
Self test diagnostics and network communication test. ↑↓E H
Diagnostics?
Utilities Modem, Ethernet, and Token Ring configuration and Wiegand analyses. ↑↓E H
Utilities?
Clear RAM Clear all data and download from RAM. ↑↓E H
Clear Ram?
Control Module Inc.
2016 Setup