Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact
Page 1 of Using the Cisco Aironet 340 Series Wireless Bridges

Manual · Cisco

Using the Cisco Aironet 340 Series Wireless Bridges

Manual218 pagesPDF 1.8 MB

User guide for the Cisco Aironet 340 Series wireless bridge: installation, console menus, radio and Ethernet setup, spanning tree and diagnostics.

Download the PDF1.8 MB

Covers · 1 model

The models it covers

Summary

What is in it

The user guide for the Cisco Aironet 340 Series wireless bridge, which joins remote Ethernet LANs into one virtual LAN and can also act as a radio access point. It covers installing the antennas, console cable, Ethernet connection and power pack, reading the indicators, and using the console by serial port, Telnet or web browser. Later chapters configure the radio network, Ethernet port, IP identifiers, Mobile IP, spanning tree, association table, filters and event logs, and explain statistics, diagnostics and firmware loading.

Its parts

  1. Welcome to the Aironet 340 Series Bridge
  2. Installing the Aironet 340 Series Bridge
  3. Accessing the Console System
  4. Before You Begin
  5. Configuring the Radio Network
  6. Configuring the Ethernet Port
  7. Setting Network Identifiers
  8. Configuring Mobile IP
  9. Using the Spanning Tree Protocol
  10. Viewing Statistics
  11. Setting Up the Association Table
  12. Using Filters
  13. Setting Up Event Logs
  14. Performing Diagnostics

From the manual

Key facts from this manual

Some pages are scans or cannot be read; this says only what the readable text supports. Each line names its page in the PDF.

User's guide (March 2000) for the Cisco Aironet 340 Series wireless bridge, which links remote Ethernet LANs over radio and can also serve as an access point. It covers installation, antennas, cabling, the indicator lights, the console menus reached by serial port, Telnet, browser or SNMP, configuration, statistics, filters, logs and firmware loading, with specifications in an appendix.

Read for this summary: pages 1, 3, 16 to 22, 28 to 37, 40 to 44, 173 to 175 and 183 to 185 of 218.

Device
Wireless bridge joining two or more remote Ethernet LANs into one virtual LAN; can also work as a radio access point p. 16
Ethernet ports
10Base2 (BNC), 10Base5 (DB-15 AUI, external transceiver required) and 10BaseT (RJ-45) p. 183
Radio
Direct sequence spread spectrum in the 2.4 GHz ISM band; half-duplex, up to 11 Mbps p. 17
Antenna
Ships with one 2.2 dBi dipole; longer range antennas available; connectors are reverse polarity TNC p. 30, 183
Console port
DCE, DB-9 female; 9600 baud, no parity, 8 data bits, 1 stop bit, ANSI; 9-pin straight through cable p. 31, 184
Power
Power pack, 120VAC/60Hz or 90-264VAC/47-63Hz to 12-18VDC by country; On/Off button p. 34, 184
Size and weight
20 x 15 x 5 cm (7.8 x 5.9 x 1.9 inches); 0.7 Kg (1 lb. 8 oz.) p. 184
Operating temperature
-20 to 50 °C (-4 to 122 °F) p. 184
Management
Console menus by serial port, Telnet, web browser or SNMP (MIB-I, MIB-II and a custom MIB) p. 17, 40
Firmware loading
Xmodem or CRC-xmodem over the console port, FTP, distribute to all units, or BOOTP/DHCP at startup p. 173, 174
Indicators
Top panel: Ethernet, Status, Radio. Back panel: 10BaseT polarity and active, Ethernet Rx and Tx, 10Base2 active, collision p. 35, 37
Package options
Lightning arrestor, mounting kit, low loss antenna cable and directional antenna p. 28
Compliance
The manual states FCC Part 15 Class B, DOC, ETS 300.328, FTZ 2100 and MPT 1349 p. 183

What this manual walks you through

  • Planning point-to-point, point-to-multipoint and repeater layouts p. 20, 21, 22
  • Site survey factors that affect radio range p. 18
  • Installing the antenna and lightning arrestor p. 29, 30
  • Connecting the console port cable and terminal p. 31
  • Attaching 10Base2, 10Base5 and 10BaseT Ethernet cabling p. 32, 33
  • Powering on and reading the top and back panel indicators p. 34, 35, 36, 37
  • Using the console menus and command line mode p. 40, 41, 42, 43, 44
  • Loading firmware with Xmodem or FTP p. 174, 175

Good to know

  • A unit at the end of a Thinnet cable needs a 50-Ohm terminator; changing cabling disrupts Ethernet traffic. p. 32
  • If a power-on test fails, the status light goes solid red and the unit stops working. p. 35
  • Losing power while flash memory is being programmed leaves invalid code, and the firmware must be reloaded. p. 175
  • All Aironet devices on the infrastructure must share the same SSID to communicate. p. 19
  • Set the IP address on all units before loading firmware by FTP. p. 175

Questions this manual answers

What terminal settings does the Aironet 340 bridge console use?

9600 baud, no parity, 8 data bits, 1 stop bit, ANSI compatible, over a 9-pin male to 9-pin female straight through cable. p. 31

What Ethernet connections does the Aironet 340 bridge have?

10Base2 with a BNC connector, 10Base5 with a DB-15 AUI connector and external transceiver, and 10BaseT with an RJ-45 connector. p. 183

What does a solid red status light on the Aironet 340 bridge mean?

A power-on test failed, and the unit stops functioning. p. 35

How is firmware updated on the Aironet 340 bridge?

Through the Diagnostics Load menu: by Xmodem or CRC-xmodem over the console port, by FTP, by distributing to other units, or by BOOTP/DHCP at startup. p. 173, 174

What antenna comes with the Aironet 340 bridge?

A single 2.2 dBi dipole antenna; longer range antennas are available. p. 183

Contents

Chapters and sections

Each line opens the PDF at its page.

  1. About the User’s Guide13
  2. Typographical Conventions15
  3. Welcome to the Aironet 340 Series Bridge16
    1. Data Transparency and Protocols16
    2. Ethernet Compatibility17
    3. Protocols Supported17
    4. Radio Characteristics17
    5. Radio Ranges18
    6. Security Features19
    7. Terminology19
    8. Bridge System Configurations20
  4. Installing the Aironet 340 Series Bridge27
    1. Before You Start28
    2. Installation29
    3. Attaching the AC/DC Power Pack and Powering On the Aironet 340 Series Bridge34
    4. Viewing the Indicator Displays35
  5. Accessing the Console System39
    1. Access Methods40
    2. Using the Console40
    3. Telnet Access44
    4. Web Access45
    5. About the Menus48
    6. Using the Configuration Console Menu49
    7. Monitoring of the DTR Signal55
  6. Before You Begin59
    1. Viewing the Configuration Menu60
  7. Configuring the Radio Network63
    1. Overview64
    2. Using the Configuration Radio Menu65
    3. Using the Configuration Radio IEEE 802.11 Menu67
    4. Packet Encapsulation (Encapsulation Menu)69
    5. Packet Encryption (Privacy Menu)71
    6. Using the Configuration Radio LinkTests Menu73
    7. Using the Configuration Radio Extended Menu79
  8. Configuring the Ethernet Port83
    1. Using the Configuration Ethernet Menu84
  9. Setting Network Identifiers87
    1. Using the Configuration Ident Menu88
  10. Configuring Mobile IP93
    1. Using the Configuration Mobile IP Menu94
32 more lines, from page 99 on
  1. Using the Spanning-Tree Protocol99
    1. Overview100
    2. How STP Protocol Works102
    3. Implementing STP Protocol106
    4. Using the Configuration STP Menu (Root Bridge Only)107
  2. Viewing Statistics119
    1. Viewing the Statistics Menu120
  3. Setting Up the Association Table131
    1. Overview132
    2. Using the Association Menu133
  4. Using Filters139
    1. Overview140
    2. Using the Filter Menu140
  5. Setting Up Event Logs155
    1. Overview156
    2. Using the Logs Menu162
  6. Performing Diagnostics169
    1. Using the Diagnostics Menu170
    2. Using the Network Menu171
    3. Loading New Firmware and Configurations (Load)173
  7. Appendix A - Aironet 340 Series Bridge Specifications183
    1. LAN Interfaces Supported183
    2. Radio Characteristics183
    3. Physical Specifications184
    4. Console Port Pin-Out185
  8. Appendix B - Console Menu Tree187
  9. Appendix C - SNMP Variables193
  10. Appendix D - Cisco Technical Support211
  11. Appendix E - Regulatory Information213
    1. Manufacturer’s Federal Communication Commission Declaration of Conformity Statement213
    2. Department of Communications - Canada Canadian Compliance Statement215
    3. European Telecommunication Standards Institute Statement of Compliance Information to User216

From the PDF’s own bookmarks.

The whole text · 25 parts

Read the manual here as text

Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.

  1. Pages 1 to 121-12
  2. Pages 13 to 1513-15
  3. Welcome to the Aironet 340 Series Bridge16-26
  4. Installing the Aironet 340 Series Bridge27-38
  5. Accessing the Console System, pages 39 to 4839-48
  6. Accessing the Console System, pages 49 to 5849-58
  7. Before You Begin59-62
  8. Configuring the Radio Network, pages 63 to 7263-72
  9. Configuring the Radio Network, pages 73 to 8273-82
  10. Configuring the Ethernet Port83-86
  11. Setting Network Identifiers87-92
  12. Configuring Mobile IP93-98
  13. Using the Spanning-Tree Protocol, pages 99 to 10899-108
  14. Using the Spanning-Tree Protocol, pages 109 to 118109-118
  15. Viewing Statistics119-130
  16. Setting Up the Association Table131-138
  17. Using Filters, pages 139 to 146139-146
  18. Using Filters, pages 147 to 154147-154
  19. Setting Up Event Logs155-168
  20. Performing Diagnostics169-182
  21. Appendix A - Aironet 340 Series Bridge Specifications183-186
  22. Appendix B - Console Menu Tree187-192
  23. Appendix C - SNMP Variables, pages 193 to 201193-201
  24. Appendix C - SNMP Variables, pages 202 to 210202-210
  25. Pages 211 to 218211-218

The file

Revision and size

RevisionText Part Number OL-0399-01, March 27, 2000
PublisherCisco Systems, Inc.
Pages218
PDF1.8 MB
TextText from the PDF itself; page 217 is a scan, read by OCR, which may hold reading errors.

The first pages · 3 of 218

Look before you download

Each page opens the PDF at that page.

Page 1
Page 1of 218
Page 2
Page 2of 218
Page 3
Page 3of 218

More documents · 1

For the same models