Using the Cisco Aironet 340 Series Wireless Bridges: Configuring the Ethernet Port

Pages 83 to 86 of 218, from Using the Cisco Aironet 340 Series Wireless Bridges

The original document is the PDF (1.8 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Cisco 340 Bridge

Page 83

Chapter 5 - Configuring the Ethernet Port

5 CHAPTER 5

Configuring the Ethernet Port This chapter describes the procedures for configuring the Ethernet Port of the Aironet 340 Series Bridge. Here’s what you’ll find in this chapter:

n

Using the Configuration Ethernet Menu n

Activating/Disabling the Ethernet Port n

Setting the Maximum Frame Size and Port Interface Type

Page 84

5-2

Aironet 340 Series Bridge

Using the Configuration Ethernet Menu The Ethernet Port is configured using the Configuration Ethernet Menu. To access this menu, select Configuration from the Main Menu then select Ethernet from the Configuration Menu. Configuration Ethernet Menu Option

Value

Description

1 - Active

[ on

]

- Connection active

2 - Size

[ 1518 ]

- Maximum frame size

3 - Port

[ auto ]

- Port selection

Enter an option number or name, “=” main menu, <ESC> previous menu >_

Activating/Disabling the Ethernet Port (Active)

NOTE: Do not activate the Ethernet Port until all other parameters have been set correctly.

The active option is used to enable or disable the Ethernet Port connection. The default setting for active is “On”. The active option should be disabled if the port on the Aironet 340 Series Bridge is not going to be used. This informs the software not to route packets to the port and stops the use of processing power for scanning for Ethernet activity.

Setting the Maximum Frame Size (Size) The size option allows you to increase the maximum size of the frames transmitted to and from the Ethernet infrastructure. Do not set the maximum frame size greater than 1518 unless you are running proprietary software that allows you to exceed this maximum. You may set the value between 1518 to 4096.

Page 85

Configuring the Ethernet Port 5 - 3

NOTE: After the parameter is changed, the unit must be restarted either by powering it “Off” and then “On,” or by using the “Diagnostics Restart” command for the change to occur.

Setting the Port Interface Type (Port) If this parameter is set to “Auto”, the Aironet 340 Series Bridge will scan for a cable at all three connections. When the bridge is wired to an Ethernet card that also scans, this parameter should be set to the port that is being configured. You may select AUI for 10base5 for thicknet, 10baseT for twisted pair, or 10base2 for coax and thinnet.

Page 86

5-4

Aironet 340 Series Bridge