Page 155
Chapter 12 - Setting Up Event Logs
12 CHAPTER 12
Setting Up Event Logs This chapter describes how to use the Logs Menu to set up and view event logs on the Aironet 340 Series Bridge. Here’s what you’ll find in this chapter:
n
Overview n
Log Descriptions n
Using the Logs Menu n
Viewing History Logs n
Clearing the History Buffer n
Specifying the Type of Logs to Print/Save/Light Status LED n
Setting Statistic Parameters n
Forwarding Logs to a Unix System
Page 156
12 - 2
Aironet 340 Series Bridge
Overview The Aironet 340 Series Bridge produces logs that record the occurrence of significant events occurring within your unit and on the infrastructure. The type of events that are recorded as logs are:
n
Information Logs: Records status changes that occur in the normal operation of the system. For example, when an end node associates to an Aironet 340 Series Bridge.
n
Error Logs: Records errors that occur occasionally, but are easily recovered from by the unit. For example, errors that occur during the reception and transmission of packets to and from the unit.
n
Severe Error Logs: Records errors which drastically affect the operation of the system. The system will continue to run, but action is required to return the unit to normal operating standards.
Information Logs BOOTP/DHCP set new IP address The BOOTP/DHCP server answered the request and assigned the unit an IP address different than the configured value. Node “node address” “device name” added A non-volatile entry was added to the association table. Node “node address” “device name” added locally “ASCII name” A new node associated with the local unit. Node “node address” “device name” restarted “ASCII name” A node that is currently associated to the local unit was reset. Node “node address” “device name” “ASCII name” removed, max radio retries A node was removed from the table because a response was not received from the node after attempts were made to transmit a packet to it. The node may have failed or moved to another cell.
Page 157
Setting Up Event Logs 12 - 3
Node “node address” “device name” “ASCII name” removed, staled out A node was removed from the table because data was not received from the node within the stale-out period. Different devices have different stale-out times. PSP nodes have very short stale-out times (around 10 seconds). Non-PSP nodes have longer times (usually several minutes). Node “node address” “device name” “ASCII name” removed, NV removed A node was removed from the association table because the operator used the “association remove” command. Node “node address” “device name” “ASCII name” removed, deassoc notice from “address” The node was removed from the association table because another bridge reported that it now has the node associated locally. This log is produced whenever a node handoff occurs. RARP set new IP address A RARP server answered a request for an IP address with an address different from the one currently saved. The currently saved value is overwritten. Associated to router “node address” This log is produced when the unit, configured as a repeater, associates to its parent node. SNMP: “command text” A SNMP management node sent the unit a “set” variable request which was successfully executed. The “command text” is a similar menu command that has the same effect as the SNMP request. SNMP access failure from “community name” “IP address” (node address) A SNMP management node attempted to access the SNMP agent with an invalid community name or a name that it was not allowed to use.
Page 158
12 - 4
Aironet 340 Series Bridge
STP: Listening for other Bridges The spanning tree protocol is listening on the backbone port to look for other bridges in the infrastructure. STP: Learning Addresses The spanning tree protocol is listening on the backbone port. It adds any addresses it sees into the Association Table before it starts forwarding packets in order to avoid flooding packets unnecessarily. STP: Forwarding Data The spanning tree protocol has allowed the backbone port to forward data packets to the radio network. STP: Port Blocked The spanning tree protocol has determined that the backbone port must be automatically disabled to prevent a loop in the infrastructure. STP Port “node address” receives hello timeout The unit whose address is given in the log, has lost contact with the designated bridge on its LAN. It will begin to arbitrate with other bridges on the LAN to see who will take over. STP: Topology Changed Somewhere on the infrastructure a new port has been enabled or disabled. Because of these possible changes to the spanning tree, the bridge will begin using a short staleout time for backbone nodes in case the location of nodes changes. TFTP is loading “file name” from “ip address” This log is produced when the BOOTP server gives the Aironet 340 Series Bridge the name of a configuration file and then the name of a firmware file to load.
Page 159
Setting Up Event Logs 12 - 5
Error Logs “Category” Error: nnn “type” errors This log is produced when any error occurs that is marked by an asterisk “*” after its count in the statistics displays. These errors are serious enough to affect the operation of the unit. See the sections on each display for an explanation of each error. Node “node address” “device name” “ascii name” removed These logs are similar to the information logs except that the node removed is a bridge. Since these nodes do not normally roam, it may be an indication that contact with a child repeater is lost. Assoctable is full The association table is completely full. To troubleshoot, try to force some radio nodes to associate to other bridges on the LAN using the specified router field in their association table. Unable to locate IP address “ip address” The unit was trying to send a packet to an IP address without knowing the hardware node ID. When this occurs, the unit will use the ARP protocol to try to determine the proper address. This log is produced if there was no answer to the ARP request. Usually the unit is trying to find the destination for the SNMP traps.
Severe Error Logs Ethernet cabling problem If no traffic has been sent or received on the Ethernet cable in the last 10 seconds, the unit will send a packet to itself to test the connection. If the transmission succeeds, the timer is reset. If it fails, this log is produced and traffic for the connection will be discarded until the test succeeds.
Page 160
12 - 6
Aironet 340 Series Bridge
Configuration is too large to save The number of commands in the configuration is too large for the available non-volatile memory. This may be caused by too many non-volatile entries in the association table. Could not program the flash memory An error occurred when trying to program a new version of the firmware into flash memory. The unit must be serviced. EEPROM on radio is invalid The radio installed in each unit contains an EEPROM (Electrically Erasable Programmable Read-only Memory) chip, identifying the type of radio installed. The contents of the EEPROM were found to be invalid. Have the unit serviced. (Bad EEPROM) Lost our association, max radio retries The unit, configured as a repeater, lost communications with its parent node after trying to send a packet the maximum number of times. The unit will try to re-associate. The problem may be a parent bridge failure. All local associations will be dropped. Lost our association, max radio naks The unit, configured as a repeater, lost communications with its parent node after trying to send a packet the maximum number of times. Each time the unit sent a packet, it received a response indicating that the parent’s receive buffers were full. The unit will try to re-associate. The likely cause is that the parent is handling too much traffic. All local associations will be dropped. Lost our association, radio restarted A radio configuration parameter has been changed. All associations will be dropped and the radio will be restarted. Lost our association, changed repeater mode A unit has changed from a root to a repeater or vice versa. If the unit is now a root unit, it will wait for nodes to associate to it. If the unit is now a repeater, it will attempt to associate to a parent.
Page 161
Setting Up Event Logs 12 - 7
Lost our association, new specified router The specified router parameter of this repeater has been changed. The unit will drop its current association and try to re-associate. Lost our association, NAK from router The unit responds as though it was associated to its parent, however, the parent does not have the association. The unit will attempt to re-associate. The parent may have been rebooted. No response to radio loopback test The "config radio extended test" command was set on and no bridge in range responded to the loopback test. If you know there are units in range, then either the local radio has failed, or if there is only one remote in range, then the remote unit’s radio may have failed. Radio Configuration Error nn The Aironet 340 Series Bridge could not program the radio hardware to operate at the correct frequency and bit rate. Have the unit serviced. Radio loopback test succeeded After having failed, the radio loopback test heard a response from a remote. The address PROM is invalid Each unit contains a Programmable Read-Only Memory (PROM) chip that contains the unit’s hardware address. During power up, the unit was not able to read a valid address from the PROM. The unit must be serviced.
Page 162
12 - 8
Aironet 340 Series Bridge
Using the Logs Menu The event logs are viewed using the Logs Menu. To access this menu, select Logs from the Main Menu. Logs Menu Option
Value
1
- History
2
- Clear
3
- Printlevel [
4
- Loglevel[
5
-
6
- Statistics
7
- Network [
8
- Bnodelog[
9
- Snmp
Description
- Log and alarm history - Clear the history buffer
Ledlevel
[
] - Type of logs to print all
] - Type of logs to save error/severe
] - Type of logs to light status led
- Set alarms on statistics off
] - Log network roaming off
[
01 - Syslog all
] - Log backbone node changes menu
] - Set-up SNMP traps
[149.023.165.131] - Unix syslogd address
02 - Syslevel
[ error/severe
] - Type of logs to send to syslog
03 - Facility
[
16
] - Syslog facility number to send
04 - Rcvsyslog
[ on
] - Enable reception of syslog messages
Enter an option number or name, “=” main menu, <ESC> previous menu >_
Viewing History Logs (History) Use the history option to view history logs of events that have occurred on the unit and the infrastructure. All logs are stored within the unit in a 10KB memory buffer. The actual number of event logs the unit saves will depend on the size of each log stored in the buffer. Log entries are always displayed in a least recent to most recent order. If the memory buffer becomes full, the oldest log in the buffer will be replaced by the most recent. Only logs that have occurred since the unit was last powered up or since the memory buffer was cleared will be saved. See “Clearing the History Buffer (Clear)”.
Page 163
Setting Up Event Logs 12 - 9
NOTE: If a power failure occurs, the logs contained in the memory will not be saved.
The display will be similar to the following: OLDEST 0:00:00 I Node 004096109e30 BRE105E Floor_2_109e30 added locally 0:00:03 I Node 0040961064de AP3500-T F3_1064de added for 004096109e30 30:35:09
NEWEST, cleared at 0:00:00 b[ackward], f[orward], n[ewest], o[ldest], a[ll], C[lear], q[uit] :
n
First Line: “OLDEST” indicates the end of the buffer display. This will appear at the end of the history log.
n
Display Lines: Displays the time since power-up that the log occurred, the severity level (I-information, E-error, or S-severe) and the actual log text.
n
Last Line: Indicates the current time and the time the buffer was last cleared by the operator. “NEWEST” indicates the start of the history log.
n
Option Line: Indicates the movement keys to use when viewing the history logs. Since displaying the entire history will take more than a screen page, use the following keys to navigate through the history log: b: Back one page in the log f: Forward one page in the log n: Moves to the newest log entry o: Moves to the oldest log entry q: Exit the History Log screen a: Dump entire log (usually captured to a file on a PC)
Clearing the History Buffer (Clear) Use the clear option to delete all logs from the history buffer.
Page 164
12 - 10
Aironet 340 Series Bridge
Specifying the Type of Logs to Print (Printlevel) Use the printlevel option to specify the type of event logs to appear on the Console screen. You will know immediately when an error or information event has occurred and then take the necessary action required. There are four levels of logging:
n
Error/Severe: Displays all error and severe logs.
n
Severe: Displays severe error logs only.
n
All: Displays all error, severe and information logs.
n
Off: No event logs will be displayed.
Specifying the Type of Logs to Save (Loglevel) Use the loglevel option to specify the type of logs you want to save to memory and view on the History Log screen. There are four levels of logging:
n
Error/Severe: Displays all error and severe logs.
n
Severe: Displays severe error logs only.
n
All: Displays all error, severe and information logs.
n
Off: No event logs will be displayed.
See “Specifying the Type of Logs to Print (Printlevel)”.
Specifying the Type of Logs to Light Status Indicator (Ledlevel) Use the ledlevel option to have the indicator status light turn amber when a specific type of error log occurs. There are four levels of logging:
n
Error/Severe: Displays all error and severe logs.
n
Severe: Displays severe error logs only.
n
All: Displays all error, severe and information logs.
n
Off: No event logs will be displayed.
See “Specifying the Type of Logs to Print (Printlevel)”.
Page 165
Setting Up Event Logs 12 - 11
Setting Statistic Parameters (Statistics) This command allows you to control how alarms are generated based on any of the available statistics kept by the bridge. Logs may be:
n
Disabled for statistics n
Generated if the statistic changes at all n
Generated if the statistic changes at a greater than specified rate
Í To Set Statistic Parameters: 1. Select statistics. Type a number or the short form. 1. ra Radio 2. re Radio error Enter one of [a number from 1 to 2, a short form]:
2. You will be prompted for the statistics category. Enter the number or the short form. The short form is used to store the command in the configuration. Radio Receive
Transmit
1 rpa Packets 2 rby Bytes 3 rfi Filtered
5 tpa Packets 6 tby Bytes 7 ter Errors
4 rer Errors Enter one of [a number from 1 to 7, a short form]:
3. Type a category number or the short form and press ENTER. 4. Choose the particular statistics that you wish to change. If any of the statistics already have an alarm associated, the current setting is displayed after the name. Enter an action, one of [off, any, rate]:
Page 166
12 - 12
Aironet 340 Series Bridge
5. Enter an action.
n
Off: Turns off any alarms based on the statistics value.
n
Any: An alarm will be generated if the statistics change value.
n
Rate: Prompts for a rate per second change. If the statistic value changes faster than this rate, an alarm is produced.
Log Network Roaming (Network) Normally the bridges only log changes in location for radio client that move to or from this unit. If the network option is enabled, log will be produced when the unit learns of any changes to radio nodes in any of the bridges any access points in the network.
Logging Backbone Node changes (BnodeLog) Normally the bridge only log changes the state or location of its own radio nodes. If you enable this item it will produce a log whenever a backbone node is discovered or its table entry stales out.
Setting up SNMP traps (Snmp) The bridge may be set up to generate SNMP traps and send them to a network management station. Logs Snmp Menu Option
Value
1 - Trapdest [ none
Description
] - IP destination for SNMP traps
2 - Trapcomm [ "public" ] - Community for SNMP traps 3 - Loglevel [ severe
4
[
- Authtrap off
] - Type of logs to cause a trap ]
- Enable authentication failure trap
Enter an option number or name, “=” main menu, <ESC> previous menu >_
Use the trapdest option to generate SNMP trap messages to a particular NMS whenever a significant event occurs. If SNMP is enabled and the trapdest option is configured with a valid IP address, then the system will generate SNMP trap messages. If the trapdest option is set to “none,” then traps will not be sent. Setting the “trapdest” parameter to address 0.0.0.0 is the same as disabling trap generation by using “none.”
Page 167
Setting Up Event Logs 12 - 13
The following trap messages will be sent as they occur:
n
A cold start trap will be sent when the unit first powers up.
n
A link up trap is sent when the configuration is changed or restored for a severe error condition.
n
A link down trap is sent when the configuration is changed or encounters a severe error condition.
n
A link up trap is sent for an Aironet 340 Series Bridge as soon as the radio is configured.
n
An authentication failure trap will be sent if an SNMP request is received with an unknown community name. This trap may be disabled by setting the “authtrap” parameter to “Off”. See “The generated trap will contain the text of the log message along with the severity of the log. See the MIB definition files for the exact layout Enabling Authentication Failure Trap (Authtrap)”.
n
Any normal alarms and logs you have configured to be sent by setting the “loglevel” parameter.
NOTE: Since the path to the trap destination may be through a failed or not yet established radio link, it is possible that cold start and link down traps could be lost.
Use the trapcomm option to specify the community name that will be used in the trap message. The LogLevel option configures The Aironet 340 Series Bridge to generate enterprise specific traps whenever a log of a given severity or higher is produced. The trapdest parameter must be “On”. The generated trap will contain the text of the log message along with the severity of the log. See the MIB definition files for the exact layout Enabling Authentication Failure Trap (Authtrap) Use the authtrap option to control the generation of SNMP authentication failure traps.
Page 168
12 - 14
Aironet 340 Series Bridge
The failure traps may be sent if an NMS sends a request with an unknown community name or a community name that it is not allowed for use. You can enable or disable this option. The default setting is “Off”.
Forwarding Logs to a Unix System (Syslog,SysLevel,Facility,Rcvsyslog) Use the syslog option to forward logs to a Unix host running the Syslogd deamon process. Enter the IP address of the Unix host. If the address remains at the default of 0.0.0.0., logs will not be sent. You may control the type of logs sent to the deamon with the Syslevel option which has the same arguments as the printlevel function described above. Packets received by the Syslogd daemon process are recorded in the system log file on the Unix host. The logs are displayed on the Console in addition to being forwarded to the Unix host. If the Aironet 340 Series Bridge should fail for any reason, the logs may still be viewed on the Unix host. The logs are sent using the syslog facility code “LOG_LOCAL0” which has a value of 16. You may change this value with the option Facility. The syslog priority depends on the priority of the log locally. On the Unix host, the Syslogd deamon process will usually add the current time and IP address of the unit that sent the log. The Aironet 340 Series Bridge will pre-pend its own name to the log before it is sent. A message similar to the following will appear on the host: Jan 11 10:46:30 192.009.200.206 A630_10172c: Node 0000c0d1587e 630 added for 004096104546
By default the bridges are set up to be able to receive and display syslog messages from other bridges in the network. The Rcvsyslog option enables or disables this function. You could choose one bridge to monitor and have all other units setup with this one as their syslog host.