Page 39

Chapter 2 - Accessing the Console System

2 CHAPTER 2

Accessing the Console System This chapter describes the methods used to access the Console system of the Aironet 340 Series Bridge. This system contains all commands necessary to configure and monitor the operation of the unit. Here’s what you’ll find in this chapter:

n

Access Methods n

Using the Console n

Telnet Access n

Web Access n

About the Menus n

Using the Configuration Console Menu n

Monitoring of DTR Signal

Page 40

2 - 2 Aironet 340 Series Bridge

Access Methods There are many ways in which you may configure and monitor the Aironet 340 Series Bridge. When the unit is powered up, basic configuration must initially be performed by accessing the Console Serial Port. To gain access through the Serial Port, the bridge must be connected to a terminal or a PC running a terminal emulation program. See Chapter 1 “Installing the Aironet 340 Series Bridge”. Set the terminal to 9600 Baud, No-Parity, 8 data bits, 1 stop bit, and ANSI compatible. Once the bridge has been assigned an IP address, you may then access the Console remotely using:

n

Telnet protocol from a remote host or PC n

HTML browser, such as Netscape Navigator from a remote host n

Simple Network Management Protocol (SNMP) from a remote network management station

Using the Console The Console system is organized as a set of menus. Each selection in a menu list may either take you to a sub-menu or display a command that will configure or display information controlling the unit. When the bridge is powered up, the main menu will be displayed. Main Menu Option

Value

Description

1 - Configuration

[ menu

]

- General configuration

2 - Statistics

[ menu

]

- Display statistics

3 - Association

[ menu

]

- Association table maintenance

4 - Filter

[ menu

]

- Control packet filtering

5 - Logs

[ menu

]

- Alarm and log control

6 - Diagnostics

[ menu

]

- Maintenance and testing commands

7 - Privilege

[ write ]

8 - Help Enter an option number or name >

- Set privilege level - Introduction

Page 41

Accessing the Console System 2 - 3

Each menu contains the following elements:

n

Title Line: Contains the product name, firmware version and menu name. It also contains the unique name assigned to the unit. See Chapter 6 “Setting Network Identifiers”.

n

Option Column : Displays the menu options and option number.

n

Value Column : Displays either the value as [menu] or displays the current settings for the option. If the value is [menu], there are additional sub-menus available.

n

Description Column : Provides a brief description of each option on the menu.

n

Enter an Option Number or Name >: The cursor prompt used to enter option numbers, names, or commands.

To select an item from the menu you may either enter the number displayed beside the selection, in which case you are immediately taken to the selection, or you may type the name listed in the option column followed by a carriage return. If you use the name method, you only need to enter enough characters to make the name unique from the other selection names in the menu. When you are entering names or command information you may edit the selection by using the BACKSPACE character to delete a single character or the DELETE character to delete the entire line.

Sub-Menus If the selection you chose is a sub-menu, the new menu will be displayed. You may now either choose a selection from this menu or return to the previous menu by pressing the ESCAPE key. If you want to return to the Main Menu, type the equal key (=) at the menu prompt.

Page 42

2 - 4 Aironet 340 Series Bridge

Commands and Information If your selection is a command, you may be prompted for information before it executes. Information may be one of the following types:

n

Token: A list of one or more fixed strings. To select a particular token, you need only enter enough of the starting characters of the token to allow it to be uniquely identified from the characters of the other tokens in the list. Enter one of [off, readonly, write] : w

You would need only enter: “o”, “r”, or “w” followed by a carriage return.

n

String: An arbitrary amount of characters. The prompt will indicate the allowable size range of the string. Enter a name of from 1 to 10 characters: “abc def”

If the string contains a space, enclose the string in quotation marks. If you wish to enter an empty string, use two quotation marks with nothing between them.

n

Integers: A decimal integer. The prompt will indicate the range of allowed values. Enter a size between 1 and 100 : 99 hexadecimal integer – a number specified in hexadecimal using the characters 0-9 and a-f or A-F. Enter a hex number between 1h and ffh : 1a n

Network address: An infrastructure or MAC level address of 12 characters or less. Omit leading zeros when entering an address. Enter the remote network address : 4096123456 n

IP address: An internet address in the form of 4 numbers from 0255 separated by dots (.). Leading zeros in any of the numbers may be omitted. Enter an IP address : 192.200.1.50

Once all information has been entered the command will execute. If the information entered changed a configuration item, the new value will be displayed in the menus.

Page 43

Accessing the Console System 2 - 5

Some configuration commands only allow the choice between two fixed values. When the menu item is selected, the opposite value to the current value is chosen. For example, if the configuration item is only a selection between on and off, and the current value is on, then selecting the menu option will select the off value. Some commands which have a severe effect on the operation of the unit (such as the restart command) and will prompt to be sure you want to execute the command. Are you sure [y/n] :

If you enter anything other than a “y” or a “Y” the command will not be executed. If you are being prompted for information, you may cancel the command and return to the menu by typing ESCAPE.

Commands That Display Information There are several types of commands that display information to the operator. All displays end with a prompt before returning back to the menus. If nothing is entered at the prompt for 10 seconds, the display will automatically refresh.

n

Single page non-statistical displays end with the following prompt. Enter space to re-display, q[uit] :

Any character other than space will cause the display to exit.

n

Single page statistical displays end with the following prompt. Enter space to re-display, C[lear stats], q[uit] :

Entering a “C” (capital) will reset all statistics to zero.

n

Multiple page table displays end with the following prompt. Enter space to redisplay, f[irst], n[ext], p[revious], q[uit] :

Parts of the prompt may or may not be present depending on the display. If you are not at the first page of the display, you may enter “f” to return to the first page or “p” to return to the previous page. If you are not at the last page you may enter “n” to go to the next page.

Page 44

2 - 6 Aironet 340 Series Bridge

Command Line Mode Another way to move within the Console is to enter commands directly from the Main Menu. Commands allow you to bypass the menu system and go directly to any level sub-menu or option. Enter the list of submenus, command names, and information separated by space characters. Example 1: To access the Radio Configuration Menu (located two submenus down): 1. At the Main Menu prompt type: configuration radio

2. Press ENTER. The Radio Configuration Menu appears. Example 2: To access the packet size option from the Radio Link Test Menu (located three sub-menus down): 1. At the Main Menu prompt type: configuration radio linktest size 25

2. Press ENTER and the Main Menu is re-displayed.

Telnet Access Once the Aironet 340 Series Bridge has been assigned an IP address and connected to the infrastructure, you may connect to the Console system from a remote PC or host by executing the telnet command. Once the connection has been made, the Main Menu will appear. The menus function in the same way for both telnet access and Serial Port connections.

Page 45

Accessing the Console System 2 - 7

While a telnet session is in progress, you may not use the Console Port to gain access to the menus. If any characters are entered, the following message is printed identifying the location of the connection. Console taken over by remote operator at 192.200.1.1 <use BREAK to end>

If you enter a break sequence, the remote operator will be disconnected and control of the Console is returned to the Console Port. You may disable telnet access to the bridge with a menu configuration command.

NOTE: If you are leaving telnet enabled, make sure you set passwords to secure the Console. See “Enabling Linemode (Linemode)”.

Web Access The Aironet 340 Series Bridge supports access to the Console system through the use of an HTML browser. To start a connection use: http://ip address of Aironet 340 Series Bridge/

The page displayed will show the general status of the unit:

Page 46

2 - 8 Aironet 340 Series Bridge

The top section of the each page contains a set of links to the various sub-pages that allow you to configure and display the status of the unit. The following is a sample configuration page

At the top left there is a “HOME” link which always returned to the main page. By default, the web pages to display so as to not allow any changes to the configuration of the unit. This is done to try and prevent any inadvertent mouse clicks from changing the configuration. To change a configuration item you must first click on the “Allow Config Changes” link in the top left corner. The page will be re-displayed in a form that allows the changes. Once the changes have been completed you should click on the “Disallow Config Changes” link to re-protect the configuartion.

Page 47

Accessing the Console System 2 - 9

Some configuration items are displayed as a list of fixed choices. The currently active choice is displayed in bold and cannot be selected. The other choices are displayed as links that may be activated by clicking on them. Other configuration items require the entry of some text. Enter the new value in the text box and then hit “Enter” to send the change to the AP for processing. For those commands that display pages of information, the prompts function the same as those on the Console Port, except instead of having to type characters to select the different options, the option is a hyperlink. You may disable web access to the bridge with a menu configuration command.

NOTE: If you are leaving web access enabled, make sure that you set passwords to secure the Console. See “Enabling Linemode (Linemode)”.

Page 48

2 - 10 Aironet 340 Series Bridge

About the Menus Perform the following general functions using menus:

n

Configuration: Allows you to configure Ethernet and Radio Parameters and establish Network Identifications. See Chapters 3-6.

n

Statistics: View a variety of statistical information such as transmit and receive data throughput, Ethernet and radio errors, and the general status of the Aironet 340 Series Bridge. See Chapter 9 “Viewing Statistics”.

n

Association Table: A table that contains the addresses of all radio nodes associated below the Aironet 340 Series Bridge on the infrastructure. You may use the association table to display, add and remove static entries, and allow automatic additions to the table. See Chapter 10 “Setting Up the Association Table”.

n

Filter: Controls packet filtering. The filter menu allows you to control forwarding of multicast messages by blocking those multicast addresses and protocols that are not used on the radio network. See Chapter 11 “Using Filters”.

n

Logs: Keeps a record of all events and alarms that occur on the unit. With the Logs Menu, you can view and/or print a history of all log entries, set alarm levels, and determine the type of logs you want to save. See Chapter 12 “Setting Up Event Logs”.

n

Diagnostics: Allows you to run link tests between the Aironet 340 Series Bridge and other infrastructure nodes to test the quality of the radio link. Use the Diagnostics function to load new code versions of the bridge’s firmware. See Chapter 13 “Performing Diagnostics”.

n

Privilege: Allows you to set privilege levels and passwords to restrict access to the Console Port’s menus and functions.

n

Help: A brief help screen outlining the procedures for accessing menus and entering commands.