Installing the Aironet 340 Series Bridge This chapter describes the procedures for installing the Aironet 340 Series Bridge. Here’s what you’ll find in this chapter:
n
Before You Start n
Installation n
Installing the Antennas n
Installing the Console Port Cable n
Installing the Ethernet Connection n
Attaching the AC/DC Power Pack and Powering On the Aironet 340 Series Bridge n
Viewing the Indicator Displays
Page 28
1-2
Aironet 340 Series Bridge
Before You Start After unpacking the system, make sure the following items are present and in good condition:
n
Aironet 340 Series Bridge n
Power Pack. The power pack will be either 120VAC/60 Hz or 90-264VAC/47-63Hz to 12-18VDC, whichever is appropriate for country of use.
n
Lightning Arrestor (Bridge Package option)
n
Mounting Kit (Bridge Package option)
n
Low loss antenna cable (Bridge Package option)
n
Appropriate directional antenna (Bridge Package option)
If any item is damaged or missing, contact your Aironet supplier. Save all shipping and packing material in order to repack the unit should service be required.
Figure 1.1 - Overview of the Aironet 340 Series Bridge
10BaseT (Twisted Pair Ethernet)
10Base5 (AUI Port)
10Base2 (BNC T-Connector) Antenna Connector Console Port RS-232 (DB-9 Female) AC/DC Power Pack Unit
Top Panel LEDs
On/Off Button
Page 29
Installing the Aironet 340 Series Bridge 1 - 3
Installation Installing the Antennas Before installing your bridge system, we recommend that you test the bridge using the 2.2 dBi dipole antenna included in your package. Once testing is completed, install your wireless bridge for use with the appropriate antenna for your application using the following the instructions. 1. With the unit powered off, attach the lightening arrestor to the antenna connector. Figure 1.2 - Attaching the Antenna
10Base5
10BaseT
10Base2
NOTE: Do not over-tighten; finger tight is sufficient. Position the antenna vertically for best omni-directional signal reception.
Page 30
1-4
Aironet 340 Series Bridge
2. Connect the lightning arrestor to one end of the low loss antenna cable.
NOTE: The lightning arrestor should be connected to the antenna connector on the wireless bridge. The lightning arrestor is added to provide surge protection to the bridge in the event of voltage surges as a result of a lightning strike.
3. Connect the antenna to the other end of the low loss antenna cable. Mount the bridge antenna at an appropriate elevation to ensure maximum path clearance and line of sight considerations.
NOTE: Due to FCC and DOC Regulations, the antenna connectors on the Aironet 340 Series Bridge are of reverse polarity to the standard TNC connectors.
Page 31
Installing the Aironet 340 Series Bridge 1 - 5
Installing the Console Port Cable 1. Attach the Console Port cable to the Serial Port. Attach the other cable end to the Serial Port on a terminal or a PC running a terminal emulation program. Use a 9-pin male to 9-pin female straight through cable (Figure 1.3).
NOTE: This connection is required for setting up initial configuration information. After configuration is completed, this cable may be removed until additional configuration is required via the Serial Port.
Figure 1.3 - Console Port Connection
2. Set the terminal to 9600 Baud, No-Parity, 8 data bits, 1 Stop bit, and ANSI compatible.
Page 32
1-6
Aironet 340 Series Bridge
Installing the Ethernet Connection The Aironet 340 Series Bridge supports three connection types:
Í n
10Base2 (Thinnet)
n
10Base5 (Thicknet) AUI connector n
10BaseT (Twisted Pair) To Attach 10Base2 (Thinnet) Cabling:
1. Make sure the unit is powered off. 2. Attach the Thinnet cabling to each end of a BNC T-connector, if applicable. 3. Attach the T-connector to the 10Base2 BNC (Figure 1.4). If the unit is at the end of the Ethernet cable, a 50-Ohm terminator must be installed on the open end of the T-connector. Figure 1.4 - Attaching 10Base2 (Thinnet) Cabling
10Base5
10BaseT
10Base2
CAUTION: Removing a terminator to install extra cable, or breaking an existing cable to install a T-connector, will cause a disruption in Ethernet traffic. Consult with your LAN administrator before you change any Ethernet cabling connections.
Page 33
Installing the Aironet 340 Series Bridge 1 - 7
Í To Attach the 10Base5 (Thicknet) Cabling: 1. Make sure the unit is powered off. 2. Attach the transceiver connector to the 10Base5 AUI port as shown in Figure 1.5. 3. Slide the locking mechanism in place. 4. Attach the other end of the transceiver drop cabling to an external transceiver. Figure 1.5 - Attaching 10Base5 (Thicknet) Cabling
10Base5
10BaseT
10Base2
Í To Attach the 10BaseT (Twisted Pair) cabling: 1. Make sure the unit is powered off. 2. Plug the RJ-45 connector into the 10BaseT (Twisted Pair) port as shown in Figure 1.6. 3. Connect the other end of the Twisted Pair cabling to the LAN connection (such as a hub or concentrator). Figure 1.6 - Attaching 10BaseT (Twisted Pair) Cabling
10Base5 10Base2
10BaseT
Page 34
1-8
Aironet 340 Series Bridge
Attaching the AC/DC Power Pack and Powering On the Aironet 340 Series Bridge 1. Insert the small plug on the end of the AC/DC power pack cord into the power port. 2. Plug the AC/DC power pack into an electrical outlet. (120VAC/60 Hz or 90-264VAC as appropriate) 3. Power on the Aironet 340 Series Bridge by pushing the On/Off button.
Figure 1.7 - AC to DC Power Pack Connections and On/Off Button
On/Off Button
When power is initially applied to the bridge, all three indicators will flash in sequence to test the functionality of the indicators.
Page 35
Installing the Aironet 340 Series Bridge 1 - 9
Viewing the Indicator Displays Top Panel Indicators The indicators are a set of displays located on the top panel of the Aironet 340 Series Bridge.
n
Ethernet Indicator – Used to indicate infrastructure traffic activity. The light is normally off, but will flash green whenever a packet is received or transmitted over the Ethernet interface.
n
Status Indicator – Shows solid green when the bridge has accepted a radio association.
n
Radio Indicator – Used to indicate radio traffic activity. The light is normally off, but will flash green whenever a packet is received or transmitted over the radio.
When the Aironet 340 Series Bridge is initially powered up, all three displays will flash amber, red and then green, in sequence. If a power-on test fails, the status indicator will go solid red and the unit will stop functioning. See Table 1.1 for a detailed explanation of the Top Panel indicators. Figure 1.8 - Top Panel Indicators
Ethernet
Status
Radio
Page 36
1 - 10
Aironet 340 Series Bridge
Table 1.1 - Top Panel Indicator Description Indicator Display Type
Description Ethernet
Nonassociated Node
Operational
Status Blinking Green
No nodes associated
Green
One or more nodes associated
Green Blinking Green
Failure Firmware Upgrade
Blinking Amber
Red
Blinking Green
Green Green
Error/Warning
Radio
Transmitting/Receiving Radio packets Transmitting/Receiving packets
Blinking Amber
Maximum retries/buffer full occurred on radio
Green
Transmit/Receive errors
Blinking Amber
General warning, check the logs
Red Red
Red
Software failure Flashing the firmware
Page 37
Installing the Aironet 340 Series Bridge 1 - 11
Back Panel Indicators The back panel indicators shown in Figure 1.9 are:
n
10BaseT polarity : Solid amber to indicate the 10BaseT polarity is reversed. Check cable connections.
n
10BaseT active : Solid green to indicate the 10BaseT has been configured as the active port.
n
Ethernet Rx : Flashes green when an Ethernet packet has been received.
n
Ethernet Tx : Flashes green when an Ethernet packet has been transmitted.
n
10Base2 active : Solid green to indicate the 10Base2 has been configured as the active port.
n
Packet Collision : Flashes amber to indicate a packet collision has occurred.
Figure 1.9 - Back Panel Indicators 10BaseT polarity Packet Collision
Ethernet Tx
10Base5
10BaseT
10Base2
10BaseT active Ethernet Rx 10Base2 active