The text of a manual · part 4 of 8
AtomScan Bar Code Scanner (Catalog No. 2755-L6SA, -L6RA, -L6SB, -L6RB) User Manual: 3 - Designing the System, pages 20 to 27
Pages 20 to 27 of 44, from AtomScan Bar Code Scanner (Catalog No. 2755-L6SA, -L6RA, -L6SB, -L6RB) User Manual
The original document is the PDF (198 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Allen-Bradley 2755-L6
Page 20
Chapter 3 Designing the System
Table 3.A and Table 3.B show the relationship among the symbol density (width of the narrowest bar or space), the Read Range, and the usable scan width. The performance may vary slightly for raster units. Figure 3.6 gives the same information as Table 3.A in graphic form. Figure 3.6 Read Range vs. Narrow Element Width mm
Mils (.001 in.)
1.25
50
45
Apparent Minimum Element Width
1.00
40
35
.75
30
“B”
25
.50
20
15
.25
10
“A” 5
0
0
Inches Centimeters
(from scan window)
0 0
1 2.5
2 5.0
3 7.5
4 10.0
5 12.5
6 15.0
7 17.5
8 20.0
9 22.5
10 25.4
Read Range
Read rates will vary due to differences in symbol quality and positioning. For optimum performance with your application: 1. Configure the decoder for Decode Mode = Continuous. See the Enhanced Decoder user’s manual (Publication No. 2755-833). The section in Chapter 14 titled Display Status and Counters has a discussion of the “decoder performance indicator” (decoder performance = read rate). 2. Map out a symbol placement area by manually moving your symbol in and out, back and forth, while observing decoder performance on the screen.
3–9
Page 21
Chapter 3 Designing the System
Raster Height A raster scanner is used when the bar code symbol is of poor quality:
• symbols printed on a dot matrix printer • bars and spaces not uniform • bars have voids or spaces have spots The raster scanner puts lines through ten locations in the symbol, which increases the probability of finding a location that can be reliably decoded. The Raster Height is the distance between the raster scan lines farthest apart at a given distance from the scanner. Distance from the Scanner
Calculating the Number of Scans Per Symbol
Raster Height inches centimeters inches millimeters
1 2 3 4 5 6 7 8 9 10
2.5 5.1 7.6 10.2 12.7 15.2 17.8 20.3 22.9 25.4
.06 .09 .13 .16 .20 .24 .27 .30 .34 .37
.15 .24 .33 .42 .50 .59 .68 .77 .86 .95
For good quality bar code symbol and a correctly aimed bar code scanner, at least 5 scans must pass through an entire symbol to assure that the symbol is decoded. With fewer scans there will be more “No Read” counts, even when the symbol is good. If the symbol is of poor quality, more scans per symbol may be required. Ladder orientation gives a different number of scans than picket fence orientation, depending on symbol height, symbol width, and scan width.
3–10
Page 22
Chapter 3 Designing the System
Picket Fence Applications To calculate minimum scans per symbol, use this formula: S = S = R= W= L = C=
R (W–L) C
(must be at least 5) Scans per label Scan Rate Scan Width at the minimum read distance Symbol Length (including quiet zones) Conveyor Speed
Scan Width, Symbol Length, and Conveyor Speed must be expressed in similar units. Calculations assume that the scanner and decoder are triggered for the entire time the symbol is present and the symbol has a 0° pitch. (See the section at the end of this chapter, “Compensating for Pitched Symbols”.)
Example: A 40 mil symbol that is 1 inch tall and 4.75 inches long (including quiet zones) is to be read in a picket fence orientation at 125 ft./min. Space is limited so the scanner must be positioned as close to the symbols as possible. The scan width must be large enough to cover the entire symbol, including the two quiet zones. At 6 inches, the 2655-L6SB scanner has a Scan Width (from Table 3.B) of 6.5 inches. The following calculation converts Conveyor Speed to inches per second: 25 125 feet minute x
12 inches foot x
1 minute 60 seconds 5
=
25 inches second
To calculate minimum scans per symbol for this application, insert these values into the formula: R = 330 scans/second W = 6.5 inches L = 4.75 inches C = 25 inches/second 13.2 330 scans x second
1.75 (6.50-4.75) inches
25 inches second
=
23 scans
Since S (scans per symbol) is greater than 5 and the application uses good quality symbols, the 2755-L6SB scanner is appropriate for this application. 3–11
Page 23
Chapter 3 Designing the System
Step Ladder Applications To calculate scans per symbol for step ladder applications, use this formula: S = S = R= H= C=
RxH C
Scans per Symbol (must be at least 5) Scan Rate Symbol Height (length of bars of the symbol) Conveyor Speed
Conveyor Speed and Symbol Height must be expressed in similar units. Calculations assume that the scanner and decoder are triggered for the entire time the symbol is present and the symbol has a 0° pitch. (See the section at the end of this chapter, Compensating for Pitched Symbols.) Example: A 40 mil bar code symbol that is 1 inch tall and 4.75 inches long is to be read in step ladder orientation at 125 ft/min. Space is limited so the scanner must be positioned as close as possible to the symbols. Since the Scan Rate is measured using seconds, and the symbol height uses inches, convert Conveyor Speed to similar units (see the previous example). To calculate minimum scans per symbol for this step ladder application, use the following values: R = 330 scans/second H = 1 inch C = 25 inches/second 13.2 330 scans second x
25 inches second
1 inch = 13.2 scans
Since S (scans per symbol) is greater than 5 and the application uses good quality symbols, the 2755-L6SB scanner is appropriate for this step ladder application.
3–12
Page 24
Chapter 3 Designing the System
Compensating for Pitched Symbols
When a symbol is pitched, the bars appear to the scanner to be narrower and closer together than if it faced the scanner squarely. For pitched symbols, you must allow for the following:
• The apparent Narrow Element width, rather than the actual Narrow Element width, must be used in determining the Read Range.
• The nearest and farthest symbol elements must be within the scanner’s Read Range.
Calculating Apparent Narrow Element Width Determine the symbol’s apparent Narrow Element width before using the Read Ranges in Table 3.A or Figure 3.6. The exaggerated view of Figure 3.7 demonstrates the apparent Narrow Element width concept. With a zero degree pitch angle, the scanner views the actual Narrow Element width. When the symbol is pitched, the Narrow Element appears smaller. Figure 3.7 Actual vs Apparent Narrow Element Width
30_ Pitch 0_ Pitch
Actual Narrow Element Width 10 mils
Actual Narrow Element Width 10 mils 30_
Apparent Narrow Element Width 10 mils
Apparent Narrow Element Width 8.7 mils
The apparent Narrow Element width is approximately the Cosine of the pitch angle, multiplied by the actual Narrow Element width. From Table 3.C, cos (30_) is 0.866. 3–13
Page 25
Chapter 3 Designing the System
Example: A 10 mil (0.25 mm) symbol including Quiet Zones is 3 inches (7.6 cm) long. It is pitched at 30_. What difference does this make in placing the scanner and in reading the symbol? Two factors reduce the Read Range of the scanner with respect to a pitched symbol: 1. the apparent Narrow Element width is first used with Table 3.A or Figure 3.6 to give the useable Read Range 2. the far end of the symbol (the end of the quiet zone) must be within the Read Range as calculated in step 1, but the near end (the other quiet zone) determines the effective distance from the scanner. Step 1. With 0_ pitch the symbol can be scanned at any distance between 2” and 7” (5.1-17.8 cm) from the face of the scanner. With 30_ pitch, the apparent Narrow Element width is calculated using this formula: Apparent Narrow Element Width = Actual Element Width x Cosine (Pitch Angle) Table 3.C gives cos (30_) = 0.866 10 mils x 0.866 = 8.7 mils Using Figure 3.6, for a Narrow Element width of:
• 10 mils, the Read Range is from 2.0” to 7.0” (5.1 to 17.8 cm) • 8.7 mils, the Read Range is from about 2.2” to 6.5” (5.6 to 16.5 cm)
Apparent Minimum Element Width
Figure 3.8 A Portion of Figure 3.6 mm
Mils (.001 in.)
.50
20
Step 1
Step 2
Step 1
15
.25
10 mil 8.7 mil
10
5
Θ 0
0
Inches Centimeters
(from scan window) 3–14
Losses due to
0 0
1 2.5
2 5.0
3 7.5
4 10.0
5 12.5
6 15.0
Read Range
7 17.5
8 20.0
9 22.5
10 25.4
Page 26
Chapter 3 Designing the System
Table 3.C Cosines and Tangents for Various Pitch Angles Use for Apparent Narrow Element
Use for Lost Read Distance
Pitch Angle = Θ
Cosine (Θ)
Pitch Angle = Θ
Tangent (Θ)
0 5 10 15 20 25 30 35 40 45 50
1.0 .996 .985 .966 .940 .906 .866 .819 .766 .707 .643
0 5 10 15 20 25 30 35 40 45 50
0 .087 .176 .268 .364 .466 .577 .700 .839 1. 1.192
Step 2. The Read Range is further shortened by the lost Read Range: (the distance of the far end of the symbol from the scanner) less (the distance of the near end).
• the far end must be within the scanner’s Read Range for the apparent Narrow Element width • the near end determines the useable scan width. See Table 3.B for scan widths at different distances from the scanner. The loss of Read Range is calculated using this formula: Lost Read Range = Bar Code Symbol Length x Tan (Pitch Angle) Table 3.C gives tan (30_) = 0.577 3” x 0.577 = 1.7” Figure 3.9 Read Range and Symbol Resolution at 0_ and 30_ Pitch 7.0 inches (17.8 cm)
Pitch (Θ) = 0_
3 inch (7.6 cm) symbol is pitched 0_. 2755-L6SB
Symbol’s Nearest and Farthest Elements 6.5 inches (16.5 cm) 4.8 Inches (12.2 cm)
Pitch (Θ) = 30_
3 inch (7.6 cm) symbol is pitched 30°.
2755-L6SB
Symbol’s Nearest Elements
Symbol’s Farthest Elements 3–15
Page 27
Chapter 3 Designing the System
Step 1 + Step 2. With both of these aspects working together, the Read Range is shorter with a pitched symbol than with one that is not pitched. This results in: a smaller depth of field, the region within which the symbol must be located if it is to be read. a smaller scan width, which is required in the formula for calculating the number of scans in picket fence orientation. In Figure 3.9, if the farther end of the symbol extends past 6.5” (16.5 cm), the scanner will not be able to read part of the symbol, causing a No-Read. In such a case, move the scanner closer to the conveyor. Conversely, if the nearer end extends past 2.2” (5.6 cm), a No-Read will result; move the scanner farther from the conveyor. Figure 3.10 Calculating the Effects of Pitch Apparent Narrow Element Width (Step 1)
Lost Read Range (Step 2) Tan (Θ) x 3” = 1.7”
Pitch (Θ) = 30_
Symbol Length L = 3”
Cos (Θ) x 10 mils = 8.7 mils Θ
Actual Narrow Element Width = 10 mils
Read Range with 0_ pitch
Θ
Read Range with 30_ pitch Read Range allowing for Narrow Element width Loss due to distance between near & far ends of the symbol Useable Read Range
2.2” to 6.5” (5.6 to 16.5 cm) 1.7” (4.4 cm)
Read Range
2.0” to 7.0” (5.1 to 17.8 cm)
2.2” to 4.8” (5.6 to 12.2 cm)
Depth of field
5.0” (12.7 cm)
Depth of field
2.6” (6.6 cm)
Scan Width
2.5” to 7.5” (6.4 to 19.0 cm)
Scan Width
2.8” to 5.2” (7.1 to 13.2 cm)
In picket fence orientation, the scanner and symbol are set as far apart as possible within the Read Range, to give the greatest number of scans per symbol. However with pitched symbols, the range is so narrow that the symbol is often placed in the center of the depth of field, where it is less apt to exceed the Read Range limits in either direction.
3–16