Page 12

Chapter

A–B

3

Designing the System Chapter Objectives

This chapter provides information needed to set up the scanner correctly, including:

• Bar code symbols • Symbol orientation • Selecting the appropriate AtomScan scanner for your application

Setup Goals

Each application must be evaluated carefully. Successful bar code scanning begins with quality bar code symbols, and the correct number, type, and location of scanners, decoders, and object sensors. Also:

• Before setting up the system, calculate the expected number of scans per symbol. Make sure the application has the number of scans it needs. If necessary, adjust the symbol speed and/or the distance between bar-coded objects.

• Position the scanner at a distance from the symbol that is within the range specified (see Table 3.A). A read rate test (see the Enhanced Decoder user’s manual, in which read rate is called “decoder performance indicator”) should be made to verify the range, and also to ensure optimum scanning and decoding.

• Avoid aiming the scanner perpendicular to the symbol, to avoid directly reflected laser light.

• If a package sensor is used, position it so it can sense the object before the symbol reaches the scan area. Note: Make sure that the scan beam does not hit the sensor’s reflector; the resulting glare can blind the scanner temporarily.

3–1

Page 13

Chapter 3 Designing the System

Bar Code Symbols

There are two basic types of bar code symbols.

One-dimensional The one-dimensional bar code symbols have one row of bars and spaces. These were among the first to be developed. Examples that can be successfully scanned by AtomScan scanners are:

• Code 39 • Code 128 • Interleaved 2-of-5 • Pharmacode • UPC • EAN

Example of UPC-A Bar Code Symbol

Two-dimensional Two-dimensional bar codes are also referred to as “stacked bar codes”, because they look like standard, one-dimensional bar code symbols stacked tightly together. Examples of two-dimensional symbols are:

• PDF417

Example of PDF417

• Code 16K • Code 49

Note: Two-dimensional symbols generally cannot be successfully scanned by AtomScan scanners.

Narrow Element Width It is very important to know the Narrow Element width of the target symbol when selecting and applying bar code scanners. The Narrow Element is defined as the narrowest bar or space in the symbol. All narrow bars and narrow spaces would be the same width if perfectly printed. However this is seldom true. Measure the narrowest bar and space and use the smaller dimension as the Narrow Element Width, to determine expected read capability. Narrow Bar

3–2

Narrow Space

Page 14

Chapter 3 Designing the System

Bar Code Symbol Length and Height When measuring a symbol, orientation must be ignored. Its height is measured from one end of a bar to the other, and its length is always the distance from one end of the symbol to the other, including the “Quiet Zones”. A Quiet Zone is the empty space before or after the bars, and is usually equal to 10 times the Narrow Element Width. Figure 3.1 Parts of a symbol H

Symbol Length = L

Symbol Height = H

Quiet Zones

L

Quiet Zones

Symbol Quality A bar code reader cannot reliably read a symbol of poor quality. We strongly advise testing proposed bar code symbol samples to ANSI Standard X3.182-1990, “Bar Code Print Quality Guideline”.

• Low-cost verifiers that can test this standard are available from several companies.

• Symbol samples can be submitted to an independent symbology testing company. The ANSI guideline specified six parametric tests plus two pass/fail tests to determine the printed symbol quality. The tests result in an overall letter grade of A, B, C, D, or FAIL assigned to the symbol.

• Grade A printed symbols: any scanner should be able to read them. • Grade B symbols: many scanners can read them, including AtomScan scanners.

• Grade C symbols may appear to decode successfully, but in production the performance may drop substantially. It is usually not worth taking a chance on symbols lower than Grade B. 3–3

Page 15

Chapter 3 Designing the System

Symbol Orientation

Bar code symbols must be in the correct position as they move by the scanner. The scan line must cross every bar, space, and both quiet zones on the same sweep. Correct: All bars are crossed by scan line

Not Correct: Some bars are not crossed by scan line

Picket Fence and Step Ladder Orientation The primary orientation of the bar code symbol can be either picket fence or step ladder. The orientation is not determined by the horizontal or vertical position of the symbol itself.

• picket fence: bars are perpendicular to the direction of travel • step ladder: bars are parallel to the direction of travel Figure 3.2 Picket Fence Orientation Scanner Mounted Above Conveyor

Direction of Travel Direction of Travel

Scanner Mounted On Side of Conveyor

3–4

Page 16

Chapter 3 Designing the System

Figure 3.3 Step Ladder Orientation

Direction of Travel Scanner Mounted On Side of Conveyor

Direction of Travel Scanner Mounted Above Conveyor

In general, ladder orientation (Figure 3.3) is preferred, because each scan covers a slightly different part of the symbol. This means that:

• imperfections in the symbol are less liable to prevent a successful read. • symbol placement is not as critical. In picket fence orientation (Figure 3.2) the symbol can be read the whole time it is in the Read Range, rather than being limited by the height of the bar code. However picket fence allows scanning of only a small part of the whole symbol. Slight imperfections such as extraneous ink or voids can cause misreads or non-reads. The quality of data in picket fence orientation can be improved by any of the following:

• Make sure the printing on the symbol is of good quality. • Tilt the scan line slightly to allow a larger part of the symbol to be scanned as it passes through the scan line. This simulates rastering.

• Use an AtomScan scanner with the raster option, since a raster scanner places ten scan lines through the symbol while the single-line scanner places only one.

When to Use a Raster Scanner Single line scanners are always used in step ladder orientation. Raster scanners are beneficial in picket fence applications with symbols printed by a dot matrix printer, or where the bars have ragged edges or voids, or where the spaces have specks in them.

3–5

Page 17

Chapter 3 Designing the System

Tilt, Pitch, and Skew

The AtomScan scanner can read a symbol correctly even if the symbol or package is not correctly oriented. Figure 3.4 shows several possible positions. Figure 3.4 Positioning Terminology

Pitched package and symbol

Skewed package and symbol

Tilted symbol

Correctly positioned symbol and package

• Tilt: A symbol is tilted when the symbol’s bars are not 90° to the scan line. The symbol can be read with any tilt, provided the scan line passes through all bars and quiet zones on each sweep for the required minimum number of scans. Tilt may reduce the number of scans in a given application. Scanners 2755-L6SB and -L6RB have elliptical spots, which may limit their tolerance for tilted symbols.

• Pitch: A symbol is pitched when the symbol’s bars are at different distances from the scanner. From the scanner’s perspective, a pitched symbol will appear to have a smaller Narrow Element width than it actually has. This may reduce both the read rate and the Read Range. However the symbol can still be read if the apparent Narrow Element width is within the scanner’s specifications. See the section at the end of this chapter, Compensating for Pitched symbols. Note: Like skew, pitch may be used deliberately to reduce specular reflection, as long as the application still has the number of scans per symbol it needs.

• Skew: A symbol is skewed when the ends of the symbol’s bars are not at the same distance from the scanner. The symbol can be read if the distance of both ends of the bar are within the scanner’s Read Range, and the skew is less than -40 degrees from the centerline. Unlike pitch, skew does not affect the read range. Note: Some skew is necessary to prevent strong reflected light (specular reflection) from interfering with a successful read. A skew between 20°-30° is ideal. Or skew may be combined with pitch to give this angle. 3–6

Page 18

Chapter 3 Designing the System

Figure 3.5 Correct Setup of Scanner

20_-30_ Scanner between 20_ and 30_ above or below the symbol

20_-30_

When using “A” range scanners to read symbols with high paper noise, increasing the skew to 30° may enhance performance.

Selecting the Correct AtomScan Scanner

To select the correct AtomScan scanner for your application, you must measure:

• the distance between the scanner and the symbol (which must be within the Read Range)

• the apparent Narrow Element width. This equals the actual measured Narrow Element width if the symbol is not pitched. See the section later in this chapter, Compensating for Pitched Symbols.

• the bar code symbol’s length and height (see Figure 3.1) • the speed at which the symbol will be travelling

3–7

Page 19

Chapter 3 Designing the System

Determining the Read Range The Read Range is the distance from the face of the scanner over which a bar code symbol can be read reliably. Read Range varies with:

• the bar code symbol’s Narrow Element width • bar code symbol quality, including print contrast In picket fence applications the scanner and symbol are usually set as far apart as possible within the Read Range, to give the greatest number of scans per symbol. Table 3.A Read Ranges Scanner

(Apparent) Narrow Element Width

Nearest and Farthest Distances from Scanner (Read Range)

mils millimeters inches centimeters

2755-L6SB and 2755-L6RB

7.5 10 20 30 40 50

.19 .25 .51 .76 1.0 1.3

2.5 - 6 2.0 - 7 2.0 - 9 3.0 -10 4.0 -10 5.0 -10

6.4 - 15.2 5.1 - 17.8 5.1 -22.9 7.6 - 25.4 10.2 - 25.4 12.7 - 25.4

2755-L6SA and 2755-L6RA

5.0 7.5

.13 .19

2.0 - 3 1.0 - 4.5

5.1 - 7.6 2.5 -11.4

Useable Scan Width The useable scan width is the distance across the scan beam in which a given symbol can be read reliably. A larger scan width will give: • more time in which a moving symbol can be read by the scanner, and/or

• more scans that can be made per symbol Table 3.B Useable Scan Width Distance from the Scanner

3–8

Useable Scan Width inches centimeters inches centimeters

1 2 3 4 5 6 7 8 9 10

2.5 5.1 7.6 10.2 12.7 15.2 17.8 20.3 22.9 25.4

1.5 2.5 3.5 4.5 5.5 6.5 7.5 8.5 9.5 10.5

3.8 6.4 8.9 11.4 14.0 16.5 19.0 21.6 24.1 26.7