Page 28
Chapter
A–B
4
Installing the AtomScan Scanner Chapter Objectives
This chapter provides the information needed to mount, wire, and correctly aim the scanner. The following subjects are covered:
• • • • •
Environmental Issues Aiming the scanner Mounting Options Package Sensor Orientation Connecting the Scanner and Package Sensor
Environmental Considerations
The AtomScan scanner is totally enclosed. It can tolerate light dust. However it is not designed for use in harsh environments such as wash-down. If your environment is harsh, consider using the NEMA Type 4 enclosed 2755-LD4x4 or 2755-LD8x4, where x is the focus code, A, B, C, or D.
Aiming the Scanner
Chapter 3 presented information necessary to select the correct scanner for your application. The most important factors to consider in mounting the scanner are:
• make sure the bar code symbol passes within the scanner’s reading range • make sure the scan line will pass through all the symbol’s bars and the quiet zones • mount the scanner so the scanning plane is 20°-30° off the perpendicular Figure 4.1 Correct Setup of Scanner
20_-30_ Scanner between 20_ and 30_ above or below the symbol
20_-30_
CAUTION: Do not stare into laser beam, to avoid damage to your eyes. 4–1
Page 29
Chapter 4 Installing the Scanner
Mounting Operations
The scanner can be mounted either from the bottom, or from the top with the optional mounting plate. The only tool you need for installation is a screwdriver. Note: The scanner must be located in a dry place, away from sunlight or bright light from any source. The decoder is mounted separately from the scanner. So is the package sensor, if used.
The thickness of the mounting surface determines the length of the four #6-32 screws required. Select a screw length no greater than the thickness of the mounting surface plus the thickness of the washers plus .175 inches (4.4mm).
!
ATTENTION: Screws projecting more than .175 inches (4.4 mm) into the scanner may damage the scanner.
Figure 4.2 Mounting Dimensions (Nominal) 2.25 in (57.15 mm) 1.40 in (35.56 mm) .32 in (8.13 mm)
2.25 in (57.15 mm) 1.50 in (38.10 mm)
Mounting holes are threaded for four #6-32 screws.
4–2
Page 30
Chapter 4 Installing the Scanner
• If you do not use the mounting plate, use the measurements given in Figure 4.2 to locate centers of mounting holes. Drill four 5/32 inch (4 mm) holes. Note: If you use the mounting plate, refer to Figure 4.3. Mount the scanner directly to the four inner holes on the plate, and use the four perimeter holes for mounting the plate to its work location..
Using the Mounting Plate The Mounting Plate (Catalog No. 2755-NM7) allows mounting on any flat surface.
3.3 in 83.82 mm 2.8 in 71.12 mm
Four countersunk holes, for attaching plate to scanner
1.5 in 2.1 in 38.1 mm 53.34 mm
Four 0.158 in (3.96 mm) diameter holes, used to mount plate to any suitable surface
Thickness of Plate = 0.1 in (2.54 mm)
0.3 in 7.62 mm
Figure 4.3 Installing With the Mounting Plate
Note: The scanner has four threaded holes for mounting screws. Mounting Plate (Catalog No. 2755-NM6)
Requires four #6-32 flathead 1/4 inch screws 4–3
Page 31
Chapter 4 Installing the Scanner
Connecting Equipment
The scanner is connected to the Enhanced Decoder through the Adapter Module. The scanner cable is plugged into the Adapter Module, and then into the scanner. Cables are available in 10-foot and 15-foot lengths, so mount the decoder within that distance. Use the steps below as a guideline when connecting equipment. 1. Make sure that power to the decoder is TURNED OFF.
!
ATTENTION: Do NOT connect or disconnect scanner when the decoder has power on.
2. Connect the scanner to the Adapter Module (Catalog No. 2755-NC18) using the RJ-45 connector of the 10-foot or 15-foot cable. 3. If a package sensor is used, connect it to the Micro-Change connector of the Adapter Module. 4. Set up the decoder.
• Connect the DB15 connector of the Adapter Module to the Scanner port of the decoder.
• Configure the decoder for your application if you have not already done so. Refer to Decoder User Manual. 5. Refer to Chapter 5 on scanner operation. Figure 4.4 A Possible Setup for a Scanning System
Package sensor
Extension Cable (if needed)
Adapter
Host
Decoder
Reflector
Atom Scan
Scanner Cable Monitor (Optional)
4–4