Manual · Allen-Bradley
PLC-5 Programmable Controllers Selection Guide 1785 and 1771
Manual60 pagesPDF 4.2 MB
Selection guide for Allen-Bradley 1785 PLC-5 programmable controllers and 1771 I/O: controllers, I/O, networks, chassis, power and software.
Filed with · 1 model
Also filed with these models on the old site
Summary
What is in it
The Allen-Bradley selection guide for building a PLC-5/1771 control system. It opens with a comparison of PLC-5 controllers by catalog number, memory, I/O and communication ports, then walks through laying out the system and selecting I/O modules (1771, 1746, FLEX, POINT and others), network communications (EtherNet/IP, ControlNet, DeviceNet, serial, DH+, remote I/O), enhanced, Ethernet, ControlNet and protected controllers, chassis, power supplies and programming software.
Its parts
- PLC-5 Comparison
- Introduction
- Select I/O Modules
- Select Network Communications
- Select Controllers
- Select Chassis
- Select Power Supplies
- Select Software
- Summary
From the manual
Key facts from this manual
Some pages are scans or cannot be read; this says only what the readable text supports. Each line names its page in the PDF.
The Allen-Bradley PLC-5 Programmable Controllers Selection Guide for 1785 and 1771 products, publication 1785-SG001B-EN-P of June 2006. It covers the Enhanced, Ethernet, ControlNet and Protected PLC-5 controllers (1785-L11B through 1785-L86B and the C15 and E versions) and does not name the 1785-LT. It helps a buyer choose controllers, I/O, networks, memory modules, batteries, 1771 chassis and power supplies for a PLC-5 system.
- Document
- Selection guide for PLC-5 controllers with 1771 chassis, I/O, power supplies, networks and software p. 1, 3
- Standard controllers
- PLC-5/11 1785-L11B: 8000 words, 512 I/O; PLC-5/20 1785-L20B: 16,000 words, 512 I/O; PLC-5/30 1785-L30B: 32,000 words, 1024 I/O p. 2
- Larger controllers
- PLC-5/40 1785-L40B: 48,000 words, 2048 I/O; PLC-5/60 1785-L60B: 64,000 words, 3072 I/O; PLC-5/80 1785-L80B: 100,000 words, 3072 I/O p. 2
- Extended-local I/O
- PLC-5/40L 1785-L40L and PLC-5/60L 1785-L60L: 2 DH+ or Remote I/O ports and 1 Extended Local I/O p. 2
- Ethernet controllers
- PLC-5/20E 1785-L20E, PLC-5/40E 1785-L40E, PLC-5/80E 1785-L80E, each with 1 Ethernet port; embedded Web server, DNS and SNMP p. 2, 35
- ControlNet controllers
- PLC-5/20C 1785-L20C15, PLC-5/40C 1785-L40C15, PLC-5/80C 1785-L80C15; ControlNet runs at 5 Mbps p. 2, 36
- Protected controllers
- PLC-5/26 1785-L26B, PLC-5/46 1785-L46B, PLC-5/86 1785-L86B, PLC-5/46C 1785-L46C15; four privilege classes with passwords p. 2, 37
- Battery
- 1770-XYC for all PLC-5 programmable controllers p. 38
- Memory modules
- EEPROM backup modules 1785-ME16, 1785-ME32, 1785-ME64; not for ControlNet PLC-5 controllers p. 38
- Chassis
- 1771 chassis: 1771-A1B 4 slots, 1771-A2B 8 slots, 1771-A3B and 1771-A3B1 12 slots, 1771-A4B 16 slots p. 39
- Power supplies
- 1771 supplies give 5V dc to the backplane, up to 8 A each; 1771-P4S 120V ac, 1 slot; 1771-P5 24V dc (20.5-30V dc), 2 slots p. 41
- Backplane current
- 1785-L11B 2.3 A; 1785-L40B, -L60B, -L80B 3.3 A; Ethernet PLC-5 3.6 A; ControlNet PLC-5 3.0 A p. 34, 35, 36
- DeviceNet
- Needs a 1771-SDN DeviceNet Scanner Module p. 4
- Backup modules
- 1785-CHBM ControlNet Hot Backup; 1785-BCM backup for controllers on a remote I/O link p. 7
What this manual walks you through
- Laying out a PLC-5 system and its networks p. 6
- Adding controller backup with 1785-CHBM or 1785-BCM p. 7
- Choosing I/O modules by application and network p. 9
- Choosing the network: EtherNet/IP, ControlNet, DeviceNet p. 21
- Choosing a PLC-5 controller by memory, I/O and ports p. 33, 34, 35, 36, 37
- Choosing a 1771 chassis and its mounting space p. 39, 40
- Choosing power supplies and sizing the transformer p. 41, 42, 43
Good to know
- A PLC-5 controller and the I/O modules it controls must be directly attached to the same network. p. 6
- Mount 1771 chassis horizontally with 153 mm (6 in.) above and below, 102 mm (4 in.) at the sides and 51 mm (2 in.) to wiring ducts. p. 40
- A transformer that is too small clips the ac wave, and the power supply may shut down modules early. p. 42
- The 1785-ME EEPROM memory modules are not for use with ControlNet PLC-5 controllers. p. 38
Questions this manual answers
How much memory does a PLC-5/40 have?
The PLC-5/40 (1785-L40B) has up to 48,000 words of user memory and 2048 I/O. p. 2
What battery does a PLC-5 use?
The 1770-XYC battery, which applies to all PLC-5 programmable controllers. p. 38
Which 1771 power supply runs on 24V dc?
The 1771-P5 and 1771-P5E take 24V dc (20.5-30V dc), give 8 A at +5V dc and use 2 chassis slots. p. 41
What chassis does a PLC-5 need?
A 1771 chassis, available with 1, 2, 4, 8, 12 or 16 module slots. p. 39
Contents
Chapters and sections
Each line opens the PDF at its page.
- PLC-5 Selection Guide - 1785 and 17711
- PLC-5 Comparison2
- Introduction3
- Select I/O Modules9
- Select Network Communications21
- Select Controllers33
- Select Chassis39
- Select Power Supplies41
- Select Software45
- Summary55