The text of a manual · part 37 of 47
TSC1 Asset Surveyor Operation Manual, pages 361 to 370
Pages 361 to 370 of 470
The original document is the PDF (4.5 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Trimble TSC1
Page 361
Laser Rangefinders
I
Activating the laser interface You can specify that you want the Asset Surveyor software to accept input from the laser rangefinder, by selecting the Laser entry from the Select sensor menu. When you do this, a check mark appears beside the Laser entry to indicate that the rangefinder interface has been activated:
Z
Once the rangefinder interface has been activated (and provided the softkey appears. Laser entry in the menu is highlighted), the Once the rangefinder interface has been activated, the Asset Surveyor software accepts communications from it. You can configure the Asset Surveyor software to automatically activate the laser rangefinder interface when you start data collection by setting the Auto-connect field to ‘Yes’, as described above.
TSC1 Asset Surveyor Operation Manual
Figure 3 psxrtdc2.eps
339
Page 362
I
Laser Rangefinders
If you attempt to activate the laser rangefinder interface and the serial port is already in use by another sensor, the Asset Surveyor software displays a message similar to the following:
The Asset Surveyor software does not activate the rangefinder interface.
34 0
TSC1 Asset Surveyor Operation Manual
Page 363
Laser Rangefinders
I
Z
Checking the laser interface When the laser rangefinder is active (and highlighted in the list of to open a status form for the rangefinder: external sensors), press f softkey to toggle between displaying slope You can press the distance/inclination and horizontal/vertical distance. This form shows the most recent offset received from the laser rangefinder. If you take further readings using the rangefinder, these appear on the status form, replacing the previous reading. You can take a reading with the ProSurvey 1000 and transmit it to the Asset Surveyor software as follows:
C
1.
Turn on the ProSurvey 1000, and optionally calibrate it (as described earlier).
2.
Aim at a suitable target point. Wait for the bearing in the head-up display to stabilize.
Warning – If you do not wait until the bearing in the head-up display settles down before pulling the laser’s trigger, then the compass measurement may be seriously inaccurate.
TSC1 Asset Surveyor Operation Manual
Figure 4: pro1000.eps
341
Page 364
I
Laser Rangefinders
3.
Keeping a steady hold on the instrument, aim through its scope and carefully pull the trigger. The distance to the target point is now displayed on the ProSurvey 1000’s head-up display. The bearing and inclination are displayed on the LED.
4.
Z
Release the trigger. When you do this, the ProSurvey 1000 sends its measurement to the TSC1 datalogger. form, you If you were viewing the laser rangefinder would see the measurement arrive on the TSC1 screen:
The Asset Surveyor software displays the distance measurement in the currently configured Distance units. The laser azimuth (bearing) is converted to a true North azimuth. If the configured North reference is ‘True’, it is immediately displayed as a true North bearing (with a ‘T’ suffix); otherwise it is displayed as a magnetic North bearing (with an ‘M’ suffix). Note – If the configured Magnetic declination is ‘Auto’, the Asset Surveyor software’s internal magnetic declination model is used to convert the magnetic laser bearing to a true north bearing. Otherwise, the manually entered declination is used for this conversion.
34 2
TSC1 Asset Surveyor Operation Manual
Figure 4 No reference (OLE)
Page 365
Laser Rangefinders
C
I
Warning – The ProSurvey 1000 always emits compass bearings relative to magnetic north. You must either specify your local magnetic declination or set the Magnetic declination field to ‘Auto’, otherwise the Asset Surveyor software does not correctly convert the magnetic compass bearings to true north.
The ProSurvey 1000 takes a few seconds to take a laser distance reading (although the bearing and inclination can be read almost immediately). If the Asset Surveyor software receives a message from the ProSurvey 1000 that lacks a distance measurement, the following warning message is displayed:
TSC1 Asset Surveyor Operation Manual
343
Page 366
I
Laser Rangefinders
I.3.5
Collecting Data The following sections outline data collection. Activating the laser interface Within Data collection, the laser rangefinder interface can be activated in one of two ways:
X
•
Automatically, if you preconfigured the Laser sensor’s Auto-connect field to ‘Yes’.
•
Manually, using the
X softkey when logging data to a file.
Checking the laser interface softkey to access the Select sensor menu to You can also use the reconfigure the laser rangefinder interface, or to check that the laser and the Asset Surveyor software are communicating correctly, as described above. Recording an offset Whenever you are collecting a point feature, you can use the ProSurvey 1000 laser rangefinder to record an offset to the feature. You can record an offset to a line, area, or quickmark feature only when you have pressed the softkey to open the offset entry form for that feature.
O
34 4
TSC1 Asset Surveyor Operation Manual
Page 367
Laser Rangefinders
I.4
I
Laser Atlanta Advantage The Laser Atlanta Advantage is a lightweight, handheld laser device, suitable for use with the Asset Surveyor software for the automated recording of offsets.
I.4.1
Hardware Specifications The following sections detail the hardware specifications of the Laser Atlanta Advantage. Dimensions The laser itself measures 25.4 cm (including grip) × 8.4 cm × 27.9 cm (10" × 3.3" × 11"). It weighs 1.9 kg (4.25 lbs), excluding the power cord. The casing is made from polycarbonate ABS. Laser details The laser can typically take measurements from 1.5 m to 760 m (5 ft to 2,500 ft) to uncooperative surfaces. For cooperative targets (for example, a reflector), the range of the laser is extended to 12,190 m (40,000 ft). The laser is accurate to ±15.2 cm (6"). Compass details A magnetic fluxgate compass is used to obtain azimuth measurements. The compass is rated at ±0.5° under laboratory conditions. In typical GIS data collection conditions, the compass tends to be accurate to around ±1°. In environments where magnetic interference is high (for example, in a vehicle), the compass can be considerably less accurate.
TSC1 Asset Surveyor Operation Manual
345
Page 368
I
Laser Rangefinders
Inclinometer details A built-in inclinometer measures vertical angles, which are used to calculate the elevation of target points. The inclinometer is accurate to 0.2°. Powering The Advantage rangefinder is powered by a self-contained 6.3 V rechargeable Ni-Cd battery, located in the handle grip. Environmental limitations The Advantage rangefinder can be used at temperatures ranging between –30°C and +60°C (–22°F to +140°F). Relative humidity should not exceed 95%, non-condensing. The Advantage should be stored at between –40°C and +80°C (–40°F to +176°F). The rangefinder should always be transported in its hard carry-case.
I.4.2
Cabling for Use with the Asset Surveyor Software The Advantage laser rangefinder can be purchased with an optional download cable. This cable provides a 9-pin connector which can be plugged directly into the ESP port of a Pro XL. For use with the Pro XR or Pro XRS, a second data cable (P/N 32287) is required as an adaptor to connect to the optional 9-pin adaptor. Connect the Advantage to its battery pack, and plug the 9-pin connector into the GPS receiver's ESP port.
34 6
TSC1 Asset Surveyor Operation Manual
Page 369
Laser Rangefinders
I
Cabling for the Pro XRS receiver If you have a Pro XRS GPS receiver, connect the Advantage laser rangefinder to your receiver and datalogger as shown in Figure I.7.
Figure I.7
Advantage laser rangefinder cabling diagram for Pro XRS with TSC1
TSC1 Asset Surveyor Operation Manual
347
Page 370
I
Laser Rangefinders
Cabling for the Pro XR receiver If you have a Pro XR GPS receiver, connect the Advantage laser rangefinder to your receiver and datalogger as shown in Figure I.8.
Figure I.8
34 8
Advantage laser rangefinder cabling diagram for Pro XR with TSC1
TSC1 Asset Surveyor Operation Manual