Page 351

Laser Rangefinders

I.3

I

Laser Atlanta ProSurvey 1000 The ProSurvey 1000 produced by Laser Atlanta is a lightweight, handheld laser device, suitable for use with the Asset Surveyor software for the automated recording of offsets.

I.3.1

Hardware Specifications The following sections detail the hardware specifications of the Laser Atlanta ProSurvey 1000. Dimensions The laser itself measures 8.4 cm × 25.4 cm × 27.9 cm (3.3" × 10" × 11"). It weighs 1.9 kg (4.25 lbs), excluding the power cord. The casing is made from cast aluminum. Laser details The laser can typically take measurements from 1.5 m to 760 m (5 ft to 2,500 ft) to uncooperative surfaces. For cooperative targets (for example, a reflector), the range of the laser is extended to 3,050 m (10,000 ft). The laser is accurate to ±15.2 cm (6"). Compass details A magnetic fluxgate compass is used to obtain azimuth measurements. The compass is rated at ±0.5° under laboratory conditions. In typical GIS data collection conditions, the compass tends to be accurate to around ±1–2°. In environments where magnetic interference is high (for example, in a vehicle), the compass can be considerably less accurate.

TSC1 Asset Surveyor Operation Manual

329

Page 352

I

Laser Rangefinders

Inclinometer details A built-in inclinometer measures vertical angles, which are used to calculate the elevation of target points. The inclinometer is accurate to 0.3°. Powering The ProSurvey 1000 rangefinder can be powered by either a rechargeable 12 V NiCd battery or a 12 V DC power source at 0.4 amps. The standard ProSurvey 1000 battery charger takes approximately 15 hours to fully charge a battery (that is, overnight). Environmental limitations The ProSurvey 1000 rangefinder can be used at temperatures ranging between –30°C and +60°C (–22°F to +140°F). Relative humidity should not exceed 95%, non-condensing. The ProSurvey should be stored at between –40°C and +80°C (–40°F to +176°F). The rangefinder should always be transported in its hard carry-case.

I.3.2

Cabling for Use with the Asset Surveyor Software The ProSurvey 1000 laser rangefinder can be purchased with an optional download cable. This cable provides a 9-pin connector which can be plugged directly into the ESP port of a Pro XL. For use with the Pro XR or Pro XRS, a second data cable (P/N 32287) is required as an adaptor to connect to the optional 9-pin adaptor. Connect the ProSurvey 1000 to its battery pack, and plug the 9-pin connector into the adaptor cable and then into the TSC1 datalogger’s serial port.

33 0

TSC1 Asset Surveyor Operation Manual

Page 353

Laser Rangefinders

I

Cabling for the Pro XRS receiver If you have a Pro XRS GPS receiver, connect the ProSurvey 1000 laser rangefinder to your receiver and datalogger as shown in Figure I.4.

Figure I.4

ProSurvey 1000 laser rangefinder cabling diagram for Pro XRS with TSC1

TSC1 Asset Surveyor Operation Manual

331

Page 354

I

Laser Rangefinders

Cabling for the Pro XR receiver If you have a Pro XR GPS receiver, connect the ProSurvey 1000 laser rangefinder to your receiver and datalogger as shown in Figure I.5.

Figure I.5

33 2

ProSurvey 1000 laser rangefinder cabling diagram for Pro XR with TSC1

TSC1 Asset Surveyor Operation Manual

Page 355

Laser Rangefinders

I

Cabling for the Pro XL receiver If you have a Pro XL GPS receiver, connect the ProSurvey 1000 laser rangefinder to your receiver and datalogger as shown in Figure I.6.

Figure I.6

ProSurvey 1000 laser rangefinder cabling diagram for Pro XL with TSC1

TSC1 Asset Surveyor Operation Manual

333

Page 356

I

Laser Rangefinders

I.3.3

Configuration for Use with the Asset Surveyor Software This section provides instructions for configuring the ProSurvey 1000 laser rangefinder itself. For more information on configuring the Asset Surveyor software to work with the ProSurvey 1000 laser rangefinder, see Using the ProSurvey 1000 with the Asset Surveyor Software, page 336. EEPROM configuration The ProSurvey 1000 contains an electrically erasable and programmable ROM chip (or EEPROM), which is used to hold a wealth of configurable settings. You can view and modify these settings using the LAEEPROM program, which can be obtained from Laser Atlanta. For operation with the Asset Surveyor software, it is critical that three of the EEPROM settings be correctly configured. These are: • range_mode, which must be set to Range (averaged)

• rs232_output_mode, which must be set to ASCII range output (on trig release)

• range_opcode, which must be set to New ProSurvey format

If any of these settings is incorrect, the ProSurvey 1000 does not output information about each laser shot in a form that can be interpreted by the Asset Surveyor software. The most likely symptom of this is that the Asset Surveyor software emits a warning beep each time the laser’s trigger is released. In addition, Trimble recommends that you set the hud_mode EEPROM setting to Bearing, so that you can watch the laser’s compass bearing stabilize in the head-up display before taking each shot.

33 4

TSC1 Asset Surveyor Operation Manual

Page 357

Laser Rangefinders

I

Calibration of the ProSurvey 1000 Whenever you use the ProSurvey 1000 after storing it for a period, or in a new environment, calibrate the ProSurvey’s compass. This is particularly important if you feel that the site in which you are working is ‘hostile’ in the sense of there being local magnetic field distortions (for example, a vehicle, pipeline, overhead or underground power cable, and so forth). The purpose of calibration is to distribute compass error smoothly through a 360° circle. Note – The calibration procedure does not modify the compass’s idea of where magnetic north is. It simply distributes local distortion of the earth’s magnetic field evenly through a 360° circle. This is important as it ensures that compass readings are locally consistent. If you want to account for an error in the compass’s determination of magnetic north, do this by entering a new value for the Magnetic declination field in the Asset Surveyor software’s Units and display configuration form. Calibration of the compass is quick and extremely simple. Follow the instructions below: 1.

Press the compass calibration control on the side of the ProSurvey 1000. This control is a black indented button on the right side of the unit (looking from the back), above and in front of the laser trigger. You are prompted in the head-up display to point the ProSurvey 1000 in approximate directions starting at 0° (due North), then turning clockwise to 45° (North East) and working around to 315° (North West) in increments of 45°.

2.

Point in the indicated direction, wait for a few seconds to allow the compass to stabilize, and squeeze the laser’s trigger. After each squeeze of the trigger, the head-up display indicates the next point of the compass.

TSC1 Asset Surveyor Operation Manual

335

Page 358

I

Laser Rangefinders

3.

After aiming in the 315° direction and squeezing the trigger, the rear panel of the ProSurvey 1000 indicates a Noise value, ranging from 0 to 9. The higher the value, the better the calibration. If the Noise value is below 5, perform the calibration again.

I.3.4

Using the ProSurvey 1000 with the Asset Surveyor Software As mentioned previously, the practical accuracy of the fluxgate compass in typical field use is around ±1–2°. This yields a steady reduction in accuracy as the distance between the laser and a target point increases. At a distance of 100–200 m, the average positional error when using the ProSurvey 1000 is approximately 2 m (in addition to the error of your GPS measurement). Testing When you first connect the ProSurvey 1000 to your Trimble GPS system, test that it is correctly configured and that all components are working correctly. Select the Configuration entry from the Asset Surveyor software’s Main menu:

33 6

TSC1 Asset Surveyor Operation Manual

Page 359

Laser Rangefinders

I

Select External sensors from the Configuration menu. The menu of available sensors appears:

S

Configuring the Asset Surveyor software Configure the special Laser sensor to work with the ProSurvey 1000. softkey. The Laser range-finder To do this, press the configuration form appears:

TSC1 Asset Surveyor Operation Manual

337

Page 360

I

Laser Rangefinders

Set the Type field to ‘ProSurvey 1000’. If you generally use the ProSurvey 1000 rangefinder when collecting data, and if you typically do not use any other type of external sensor, then set the Auto-connect field to ‘Yes’. Set the Confirm offsets field to ‘On’ to display the Offset form for the currently open feature whenever you send an offset from a laser rangefinder. Set the Confirm offsets field to ‘Off’ to automatically record offset values to the open feature when you fire the rangefinder. The Offset form does not appear unless an entry is required, when it will appear automatically. The message Offset received appears briefly in the status line, but no other notification appears unless an entry is required. You can press in the attribute entry form to open the Offset form if you want to confirm offset values.

O

Set the Serial port according to the port you connect the ProSurvey 1000 to, either ‘Top’ or ‘Bottom’. Press

33 8

\ to save these settings and return to the Select sensor menu.

TSC1 Asset Surveyor Operation Manual

Figure 3 psxrtdc1.eps