Page 371

Laser Rangefinders

I

Cabling for the Pro XL receiver If you have a Pro XL GPS receiver, connect the Advantage laser rangefinder to your receiver and datalogger as shown in Figure I.9.

Figure I.9

Advantage laser rangefinder cabling diagram for Pro XL with TSC1

TSC1 Asset Surveyor Operation Manual

349

Page 372

I

Laser Rangefinders

I.4.3

Configuration for Use with the Asset Surveyor Software This section provides instructions for configuring the Advantage laser rangefinder itself. For more information on configuring the Asset Surveyor software to work with the Advantage laser rangefinder, see Using the Advantage with the Asset Surveyor Software, page 351. EEPROM configuration The Atlanta Advantage contains an electrically erasable and programmable ROM chip (or EEPROM), which is used to hold a wealth of configurable settings. You can view and modify these settings using the LAEEPROM program, which can be obtained from Laser Atlanta. For operation with the Asset Surveyor software, two of the EEPROM settings must be correctly configured. These are: • range_mode, which must be set to Standard (averaged)

•

Serial Format, which must be set to Trimble Pro XL

If any of these settings is incorrect, the Advantage does not output information about each laser shot in a form that can be interpreted by the Asset Surveyor software. The most likely symptom of this is that the Asset Surveyor software emits a warning beep each time the laser’s trigger is released. Calibration of the Advantage Whenever you use the Advantage after storing it for a period, or in a new environment, calibrate the Advantage’s compass. This is particularly important if you feel that the site in which you are working is “hostile” in that there are local magnetic field distortions (for example, a vehicle, pipe-line, or overhead or underground power cable). The purpose of calibration is to distribute compass error smoothly through a 360° circle.

35 0

TSC1 Asset Surveyor Operation Manual

Page 373

Laser Rangefinders

I

Calibration of the compass is quick and extremely simple. Follow the instructions below: 1.

Press the compass calibration control option on the HUD (Heads Up Display). You are prompted in the head-up display to point the Advantage in approximate directions starting at 0° (due North),

2.

Press Start.

3.

In a clockwise direction moving in a 360° turn, adjust the pitch and roll of the Advantage for 60 seconds. After this, a number should appear (from 0 to 9) in the display. The higher the number, the better the calibration. If this value is below 5, perform the calibration again.

Note – The calibration procedure does not modify the compass’s idea of where magnetic north is. It simply distributes local distortion of the earth’s magnetic field evenly through a 360° circle. This is important as it makes sure that compass readings are locally consistent. If you want to account for an error in the compass’s determination of magnetic north, do this by entering a new value for the Magnetic declination field in the Asset Surveyor software’s Units and display configuration form.

I.4.4

Using the Advantage with the Asset Surveyor Software As mentioned previously, the practical accuracy of the fluxgate compass in typical field use is around ±1°. This yields a steady reduction in accuracy as the distance between the laser and a target point increases. At a distance of 100–200 m, the average positional error when using the Advantage is approximately 1 m (in addition to the error of your GPS measurement).

TSC1 Asset Surveyor Operation Manual

351

Page 374

I

Laser Rangefinders

Testing When you first connect the Advantage to your Trimble GPS system, test that it is correctly configured and that all components are working correctly. Select the Configuration entry from the Asset Surveyor software’s Main menu:

Select External sensors from the Configuration menu. The menu of available sensors appears:

35 2

TSC1 Asset Surveyor Operation Manual

Page 375

Laser Rangefinders

I

S

Configuring the Asset Surveyor software Configure the special Laser sensor to work with the Laser Atlanta softkey. The Laser range-finder Advantage. To do this, press the configuration form appears:

Set the Type field to ‘Atlanta Advantage’. If you generally use the Advantage rangefinder when collecting data, and if you typically do not use any other type of external sensor, then set the Auto-connect field to ‘Yes’. Set the Confirm offsets field to ‘On’ to display the Offset form for the currently open feature whenever you send an offset from a laser rangefinder. Set the Confirm offsets field to ‘Off’ to automatically record offset values to the open feature when you fire the rangefinder. The Offset form does not appear unless an entry is required, when it will appear automatically. The message Offset received appears briefly in the status line, but no other notification appears unless an entry is required. You can press in the attribute entry form to open the Offset form if you want to confirm offset values.

O

Set the Serial port according to the port you connect the Atlanta Advantage to, either ‘Top’ or ‘Bottom’. Press

\ to save these settings and return to the Select sensor menu.

TSC1 Asset Surveyor Operation Manual

353

Page 376

I

Laser Rangefinders

Activating the laser interface You can specify that you want the Asset Surveyor software to accept input from the laser rangefinder, by selecting the Laser entry from the Select sensor menu. When you do this, a check mark appears beside the Laser entry to indicate that the rangefinder interface has been activated:

Z

Once the rangefinder interface has been activated (and provided the softkey appears. Laser entry in the menu is highlighted), the Once the rangefinder interface has been activated, the Asset Surveyor software accepts communications from it. You can configure the Asset Surveyor software to automatically activate the laser rangefinder interface when you start data collection by setting the Auto-connect field to ‘Yes’, as described above.

35 4

TSC1 Asset Surveyor Operation Manual

Page 377

Laser Rangefinders

I

If you attempt to activate the laser rangefinder interface and the serial port is already in use by another sensor, the Asset Surveyor software displays a message similar to the following:

The Asset Surveyor software does not activate the rangefinder interface.

TSC1 Asset Surveyor Operation Manual

355

Page 378

I

Laser Rangefinders

Z

Checking the laser interface When the laser rangefinder is active (and highlighted in the list of to open a status form for the rangefinder: external sensors), press f softkey to toggle between displaying slope You can press the distance/inclination and horizontal/vertical distance. This form shows the most recent offset received from the laser rangefinder. If you take further readings using the rangefinder, these appear on the status form, replacing the previous reading. You can take a reading with the Advantage and transmit it to the Asset Surveyor software as follows:

C

35 6

1.

Turn on the Advantage, and optionally calibrate it (as described earlier).

2.

Aim at a suitable target point. Wait for the bearing in the head-up display to stabilize.

Warning – If you do not wait until the bearing in the head-up display settles down before pulling the laser’s trigger, then the compass measurement may be seriously inaccurate.

TSC1 Asset Surveyor Operation Manual

Page 379

Laser Rangefinders

3.

I

Keeping a steady hold on the instrument, aim through its scope and carefully pull the trigger. The distance to the target point is now displayed on the Advantage’s head-up display. The bearing and inclination are displayed on the LED.

4.

Z

Release the trigger. When you do this, the Advantage sends its measurement to the TSC1 datalogger. form, you If you were viewing the laser rangefinder would see the measurement arrive on the TSC1 datalogger’s screen:

The Asset Surveyor software displays the distance measurement in the currently configured Distance units. The laser azimuth (bearing) is converted to a true North azimuth. If the configured North reference is ‘True’, it is immediately displayed as a true North bearing (with a ‘T’ suffix); otherwise it is displayed as a magnetic North bearing (with an ‘M’ suffix). Note – If the configured Magnetic declination is ‘Auto’, the Asset Surveyor software’s internal magnetic declination model is used to convert the magnetic laser bearing to a true north bearing. Otherwise, the manually entered declination is used for this conversion.

TSC1 Asset Surveyor Operation Manual

357

Page 380

I

Laser Rangefinders

C

Warning – The Advantage always emits compass bearings relative to magnetic north. You must either specify your local magnetic declination or set the Magnetic declination field to ‘Auto’, otherwise the Asset Surveyor software does not correctly convert the magnetic compass bearings to true north.

The Advantage takes a few seconds to take a laser distance reading (although the bearing and inclination can be read almost immediately). If the Asset Surveyor software receives a message from the Advantage which lacks a distance measurement, the following warning message is displayed:

35 8