CBL 2 Technical Reference

Manual63 pagesPDF 424 KB

Technical reference for the Texas Instruments CBL 2 calculator-based lab: sampling modes, sensor specs, commands and sample programs.

Download the PDF424 KB

Covers · 1 model

The models it covers

Summary

What is in it

The technical reference for the Texas Instruments CBL 2 (Calculator-Based Laboratory), written for users who program the CBL 2 and TI graphing calculators themselves. It explains the realtime, non-realtime and FastMode data collection modes, beep sequences and the FLASH archive, gives specifications for the light, stainless steel temperature and voltage sensors and custom sensor pinouts, documents every CBL 2 command with programming examples, and lists error messages and DataMate sensor defaults.

Its parts

  1. Introduction
  2. Miscellaneous Reference Information
  3. Technical Specifications for Sensors
  4. Programming the CBL 2

From the manual

Key facts from this manual

Each line names its page in the PDF.

Texas Instruments technical reference (2000) for the CBL 2 calculator-based data collection interface, written for people who program the CBL 2 themselves from TI graphing calculators. It gives the data collection modes, beep codes, sensor specifications and connector pinouts, the command set with sample programs, error codes, and DataMate default sensor settings.

Read for this summary: pages 1 to 17, 22 and 56 to 59 of 63.

What it is
Data collection interface for TI graphing calculators; its software sits in FLASH and can be upgraded p. 5
Connectors
Analog CH1, CH2, CH3, SONIC (right-hand) and DIG IN/OUT (left-hand), all 6-pin British Telecom-style p. 16
Analog inputs
10-bit A/D; Vin ±10 Volts at 19.6 mV resolution, Vin-low 0 to 5 Volts at 5.6 mV p. 16
Collection modes
Realtime, non-realtime or FastMode (one analog channel at a very fast rate) p. 5
Data memory
24K dedicated to data, up to 12,000 samples per collection p. 6, 58
Sample rate
Non-realtime: as fast as 1E-4 second on one channel; realtime: no more than a few points each second p. 6
Analog current limit
160 mA at most from all three analog channels p. 15
Digital output
4 bits wide, CMOS (0-5V) compatible, fed from a 32-element circular buffer p. 17
Temperature sensor
Stainless Steel Temperature Sensor, included: 20 kΩ NTC thermistor, -25 to 125°C, ±0.2°C at 0°C, ±0.5°C at 100°C p. 10, 11
Light sensor
TI light sensor: 10µW/cm2 to 1mW/cm2, 300nm to 1100nm, relative readings, air only p. 10
Voltage sensor
TI voltage sensor reads ±10 Volts on CH1, CH2 or CH3 p. 13
Motion detector
Channel 11 (SONIC): ½ meter to 6 meters, or 1½ feet to 18 feet p. 14
Custom sensor parts
Analog Probe Kit CBL/CA/D; for digital sensors, a cut CBR-to-CBL cable CBR/CA/C p. 15
Power
Batteries or the AC9920 adapter p. 58

What this manual walks you through

  • Choosing realtime, non-realtime or FastMode data collection p. 5, 6, 7
  • What the beep sequences mean p. 8, 9
  • Archiving data sets and programs in FLASH memory p. 9
  • Specifications of the light, temperature and voltage sensors p. 10, 11, 12, 13
  • Auto-ID resistor values and ranges of supported sensors p. 14
  • Building a custom analog or digital sensor p. 15
  • Sensor connector pinouts p. 16
  • Programming the digital output buffer p. 17
  • Summary of the CBL 2 commands p. 22
  • Error numbers and their causes p. 56, 57, 58, 59

Good to know

  • Never connect the analog input grounds to different potentials; they are common and the CBL 2 may be damaged. p. 13
  • The digital probe kit of the original CBL does not work with the CBL 2. p. 15
  • The Stainless Steel Temperature Probe cannot be recalibrated. p. 12
  • In FastMode, a GET sent before sampling ends aborts the sampling with an error. p. 7
  • The light sensor works in air only and is not waterproof. p. 10

Questions this manual answers

How do I find out which error the CBL 2 has?

Send the request for status (Command 7) and read the error parameter of the returned list. An error usually sounds the low tone and flashes the red LED three times. p. 22, 56

What does CBL 2 error 80 mean?

The battery voltage is too low to safely write to FLASH memory; replace the batteries. p. 58

What does CBL 2 error 99 mean?

The current load on the analog or digital ports is more than the unit can supply, so it turned the power off. Correct the problem before sampling again. p. 59

How many samples can the CBL 2 store?

Up to 12,000 samples in non-realtime collection, from 24K of data memory. p. 58

Does the original CBL temperature sensor work with the CBL 2?

Yes. It auto-identifies as the Stainless Steel Temperature sensor and uses the same built-in calibration. p. 13

Contents

Chapters and sections

Each line opens the PDF at its page.

  1. Title Page1
  2. Introduction5
  3. Miscellaneous Reference Information5
    1. CBL 2 Software Upgrades5
    2. Data Collection Modes5
    3. Beep Sequences8
    4. Archiving in CBL 2's FLASH Memory9
  4. Technical Specifications for Sensors10
    1. TI Light Sensor10
    2. Stainless Steel Temperature Sensor10
    3. TI Voltage Sensor13
    4. Auto-ID Sensors14
    5. Custom Sensors15
  5. Programming the CBL 217
    1. Digital Output Buffer17
    2. Triggering and Thresholds18
    3. Measuring Period and Frequency19
    4. Asynchronous/ Synchronous Triggering versus Record Time21
    5. CBL 2 Command Summary22
    6. Command 0 Reset CBL 2 RAM23
    7. Command 1 Channel Setup23
    8. Command 2 Data Type26
    9. Command 3 Trigger Setup26
    10. Command 4 Conversion Equation Setup (Analog)28
    11. Command 4 Sonic Temperature Compensation (Sonic)30
    12. Command 5 Data Control30
    13. Command 6 System Setup31
    14. Command 7 Request System Status31
    15. Command 8 Request Channel Status33
    16. Command 9 Request Channel Data33
    17. Command 10 Advanced Data Reduction33
    18. Command 12 Digital Data Capture34
    19. Command 102 Power Control Command41
    20. Command 115 Check Set-up Information42
    21. Command 116 Check Long Sensor Name42
    22. Command 117 Check Short Sensor Name43
    23. Command 1998 Set LED Command43
    24. Command 1999 Sound Command43
    25. Command 2001 Direct Output to Digital-Out Port44
5 more lines, from page 44 on
  1. Command 201 Archive Operations Command44
    1. Programming Examples49
  2. Appendix A: Glossary55
  3. Appendix B: CBL 2 Error Messages56
  4. Appendix C: DataMate Sensor Setup Default Settings60

From the PDF’s own bookmarks.

The whole text · 9 parts

Read the manual here as text

Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.

  1. Title Page1-4
  2. Introduction5-9
  3. Technical Specifications for Sensors10-16
  4. Programming the CBL 2, pages 17 to 2617-26
  5. Programming the CBL 2, pages 27 to 3627-36
  6. Programming the CBL 2, pages 37 to 4637-46
  7. Programming the CBL 2, pages 47 to 5447-54
  8. Pages 55 to 5955-59
  9. Appendix C: DataMate Sensor Setup Default Settings60-63

The file

Revision and size

Revision2000
PublisherTexas Instruments Incorporated
Pages63
PDF424 KB
TextText from the PDF itself.

The first pages · 3 of 63

Look before you download

Each page opens the PDF at that page.

Page 1
Page 1of 63
Page 2
Page 2of 63
Page 3
Page 3of 63

More documents · 1

For the same models