Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 8 of 9

CBL 2 Technical Reference, pages 55 to 59

Pages 55 to 59 of 63: Appendix A: Glossary; Appendix B: CBL 2 Error Messages

The original document is the PDF (424 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Texas Instruments CBL2 System

Page 55

Appendix A: Glossary The following terms are used in the CBL 2 documentation.

Term

Definition accuracy

The degree of conformity of a measure to a standard or a true value archive

Store data or programs in the FLASH memory of the CBL 2. (See page 9.)

auto-ID

Automatic Identification. Feature that allows the CBL 2 to automatically identify specific sensors when they are connected to a CBL 2 channel.

CMOS

Complementary Metal Oxide Semiconductor

FASTMODE

A data collection mode in which the CBL 2 collects data on a single analog channel at a very fast sample rate, stores it internally until all of the data points are taken, and then sends it to the calculator.

FLASH

FLASH is a technology built into CBL 2 that lets you electronically upgrade the CBL 2’s operating system by downloading future releases from TI’s web site.

non-realtime

A data collection mode in which the CBL 2 collects data, stores it internally until all the data is collected, and then sends it to the calculator.

precision

The degree of refinement with which an operation is performed or a measurement stated realtime

A data collection mode in which the CBL 2 collects data and sends it to the calculator as each point is taken.

resolution

The process or capability of making distinguishable the individual parts of an object

TTL

Transistor-Transistor-Logic

CBL 2 Technical Reference

A-1

Page 56

Appendix B: CBL 2 Error Messages Error messages that may occur when using CBL 2 without the DataMate program are listed in this section. In almost all cases, an error result causes the unit to sound the “low tone” three times and to illuminate the red LED three times. When this happens, send the request for status message and then observe the “error” parameter of the list returned. The “error” parameter will be one of the values in the table below.

Error Number

Error Cause

0

This is normal. No corrective action is needed.

1

Invalid FASTMODE. An attempt to select fast sampling mode was made. When in FASTMODE, only a single analog channel can be active. This error number also displays if the FASTMODE selection is a value other than 0 or 1.

2

FASTMODE ABORT. During FASTMODE, an attempt to communicate with the CBL 2 was made while it was waiting for a trigger. As a result, sampling was aborted.

5

The list being sent contains a number that is too large to be represented internally. This can only happen when the list being sent contains an error.

6

The list being sent contains a non-integer number where only integers are allowed. For example, command numbers must be integers and a command of 3.5 will produce this error.

8

The list being sent contained too many numbers for proper conversion. In general, no more than 32 numbers can be sent for some commands and no more than 44 numbers for other commands.

9

The command number sent (first number of the list) did not specify a valid command.

12

The channel selected for setup did not exist. Channel numbers must be 1-3, 11, 21, 31.

13

The operation selected for the channel being setup is invalid. For example, sonic channels cannot be setup for a voltage probe.

14

An invalid value was selected for the post processing parameter. This must be a number from 0 to 2.

16

An invalid equation on/off parameter was found. The equation on/off parameter must be a 0 or a 1.

17

An invalid Frequency/Period selection parameter was found. This error usually occurs when a second channel is selected for a measurement during Frequency/Period measurements.

CBL 2 Technical Reference

B-1

Page 57

Error Number

B-2

Error Cause

18

Multiple channels are not allowed to be selected at the same time for the Digital/Sonic inputs. This error usually means that the sonic port and a corresponding digital port have been selected.

22

Command 2 contains invalid data.

30

The filter type must be between 0 and 6 for NON-REALTIME data collection mode and 0, 7, 8, or 9 for real time data collection mode. This error results from a filter selection outside of this range.

31

Command 3 was sent prior to performing any channel setups.

32

Sample time must be greater than 0 and less than 16000 seconds. The value is normally rounded to the nearest 100 µsec, but can be rounded to the nearest 50 µsec in FASTMODE. If the selected channels cannot support the rate selected, a slower sample rate will be used.

33

The number of samples must be -1 for real time sampling and between 1 and 12,000 for NON-REALTIME sampling. 0 is not allowed except for a special case of real time sampling with manual entry.

34

Trigger type must be an integer between 0 and 6. Any other value will produce this error.

35

The trigger channel must be a valid channel number (e.g., 1-3 or 11) and must be have been enabled using the channel select command.

36

The trigger threshold must be a value between the maximum and minimum legal values for the sensor selected. For example, for the +/-10V probe, legal values are from –10V to +10V.

37

The prestore value must be an integer between 0 and 100%. Any other values will produce this error message.

38

The external clock parameter is limited to values of 0 or 1. Any other value will produce this error.

39

The record time parameter is limited to values between 0 and 2. Any other values will produce this error message.

40

This error will occur when too few parameters are sent in the list. For example, when setting up an equation with 5 constants, if only 4 are sent, this error will result.

42

The equation channel number must be a 0 to reset equation, or a 1-3 for the analog channels or 11 for the sonic channel. Equation numbers outside of this range will produce this error.

43

The equation number must be in the range of .1 to 12 for analog channels and either 0 or 13 for the sonic channel. Equation numbers outside of this range will produce this error.

44

The order of the equation must be appropriate for the equation type selected. For example, an equation order of 5 is not valid for the mixed polynomial equation.

CBL 2 Technical Reference

Page 58

Error Number

Error Cause

45

This error occurred because (1) equations were enabled when sending Command 1, but the equation was never sent using Command 4, or (2) GET statement was issued before sending Command 4.

49

Invalid units were selected for temperature when sending the temperature for the sonic to use. Valid values are from 0 to 4.

52

A channel was selected that is not a valid channel. The channel numbers are 1-3, 11, 21, and 31.

53

A data group was selected that is not valid. Valid values are from 0 to 5.

54

The beginning-of-data selector must be 0 (for start of data) or 1 through the number of points collected. A number outside of this range will produce this error message.

55

The end-of-data selector must be 0 (for end of data) or 1 through the number of points collected. A number outside of this range will produce this error message. In addition, the end of the data must not be before the beginning of the data.

59

Digital probe has failed to read or write as commanded by the host.

61

An attempt has been made to collect more data than can be stored in one data collection. This unit has 24K of memory dedicated to data storage, allowing up to 12K samples to be stored. (for example, 3072 samples per channel for 4 channels.) If more than this is attempted, an error will result.

62

This error results when an attempt to return data is made and data has not been collected.

63

This error results when sending Command 6 and an invalid second parameter.

76

This error results when sending Command 10 for a channel that does not have data stored.

77

This error results when sending a Command 10 and selecting an algorithm that has not been defined.

78

This error results when advanced algorithm is selected and the input parameters for it are not correct.

80

This error indicates that the battery voltage is too low to safely write to FLASH memory and an attempt has been made to write to FLASH memory. The batteries should be replaced immediately for the unit to continue to perform properly.

81

This error indicates that an attempt to write to the FLASH memory failed and that the FLASH memory did not retain the value written. This problem can occur under several circumstances including the batteries becoming low after a FLASH write has been started (or removing the AC9920 adapter during FLASH writes). If the problem occurs often, this could indicate a hardware failure.

CBL 2 Technical Reference

B-3

Page 59

Error Number

B-4

Error Cause

82

This error indicates an attempt was made to change the contents of FLASH memory without properly enabling FLASH writes.

83

This error indicates that the FLASH memory directory is full and an attempt to write to the FLASH memory occurred. If this occurs, delete some items from FLASH memory and repeat.

84

This error indicates an attempt was made to access an item in the FLASH memory that does not exist.

85

This error indicates that an attempt was made to access an item that is in the FLASH memory, but hasn’t been properly opened for access.

86

This error indicates that the archive data type is not one of the data formats supported. This error can result from trying to archive a data set that has not been properly stored.

87

The data to be archived must be NON-REALTIME data. Real time data cannot be archived. This error results when trying to archive real time data.

88

This error results when an attempt is made to archive data during sampling. Archive operations must occur only when the unit is idle.

97

This error indicates an attempt to use a channel that does not exist on CLB2 (for example, channel 42).

98

This error indicates an undefined error has occurred.

99

This error indicates that the current load on the analog or digital ports is more than can be supplied by the unit and the power has been turned off to prevent damage. Do not attempt to restart sampling until the problem has been corrected.

CBL 2 Technical Reference