CBL 2 Technical Reference: Appendix C: DataMate Sensor Setup Default Settings
Pages 60 to 63 of 63, from CBL 2 Technical Reference
The original document is the PDF (424 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Texas Instruments CBL2 System
Page 60
Appendix C: DataMate Sensor Setup Default Settings The table that follows shows the default settings used by the DataMate program. This sensor and calibration information applies only to Vernier and TI sensors. The use of other manufacturers’ sensors may require calibration or the input of that sensor’s calibration information into DataMate. Note: Default settings apply only when using a single sensor that is connected to Channel 1.
Short Name
Sensor Name
Sample Interval
Y-Min
Y-Max
(in seconds)
No. Of Samples
Dir connect Temp (C)
TEMP(C)
-15
110
1
180
Dir connect Temp (F)
TEMP(F)
0
250
1
180
Extra Long Temp (C)
TEMP(C)
-50
150
1
180
Stainless Temp (C)
TEMP(C)
-20
125
1
180
Stainless Temp (F)
TEMP(F)
-5
260
1
180
Thermocouple (C)
TEMP(C)
-200
1400
1
180 pH
PH
0
14
2
60
Conduct 200 (mS)
CONDUCT (MICS)
0
200
1
180
Conduct 100(MG/L)
TDS(MG/L)
0
100
1
180
Conduct 2000(mS)
CONDUCT (MICS)
0
2000
1
180
Conduct 1000(MG/L)
TDS(MG/L)
0
1000
1
180
Conduct 20000(mS)
CONDUCT (MICS)
0
20000
1
180
Conduct 10000(MG/L)
TDS(MG/L)
0
10000
1
180
Gas Pressure (KPA)
PRESS (KPA)
50
150
10
90
Gas Pressure (MMHG)
PRESS (MMHG)
400
1200
10
90
Gas Pressure (ATM)
PRESS (ATM)
0.5
1.6
10
90
Gas Pressure (INHG)
PRESS (INHG)
0
65
10
90
Pressure (KPA)
PRESS (KPA)
0
700
1
180
CBL 2 Technical Reference
C-1
Page 61
Sensor Name
Short Name
Sample Interval
Y-Min
Y-Max
(in seconds)
No. Of Samples
Pressure (ATM)
PRESS (ATM)
0
700
1
180
Pressure (MMHG)
PRESS (MMHG)
0
5200
1
180
Bio Pressure (KPA)
PRESS (KPA)
76
156
10
90
Bio Pressure (MMHG)
PRESS (MMHG)
550
1200
10
90
Bio Pressure (ATM)
PRESS (ATM)
0.75
1.6
10
90
Bio Pressure (INHG)
PRESS (INHG)
20
50
10
90
Dual R Force (5N)
FORCE(N)
-5
5
0.05
100
Dual R Force (10N)
FORCE(N)
-10
10
0.05
100
Dual R Force (50N)
FORCE(N)
-50
50
0.05
100
Student Force (N)
FORCE(N)
-40
10
0.05
100
EX Heart Rate (BPM)
Heart RT(BPM)
45
170
5
180
Heart Rate (BPM)
Heart RT(BPM)
45
170
5
180
25G Accel (M/S 2)
ACCEL (M/S 2)
-250
250
0.05
100
Low G Accel (M/S 2)
ACCEL (M/S 2)
-50
50
0.05
100
Colorimeter
ABSORBANCE
0
0.6
5
180
CO 2 Gas (PPM)
CO 2 GAS (PPM)
0
5000
10
30
CO 2 Gas (PPT)
CO 2 GAS (PPT)
0
5
10
30
CBL Microphone
MICROPHONE
0
5
1.00E-04
200
ULI Microphone
MICROPHONE
0
5
1.00E-04
200
MPLI Microphone
MICROPHONE
-5
5
1.00E-04
200
TI Light Sensor
LIGHT
0
1
0.05
180
C-2
CBL 2 Technical Reference
Page 62
Sample Interval
Short Name
Y-Min
Y-Max
(in seconds)
No. Of Samples
Light 600(LX)
LIGHT(LX)
0
600
0.05
180
Light 6000(LX)
LIGHT(LX)
0
6000
0.05
180
Light 150000(LX)
LIGHT(LX)
0
150000
0.05
180
D. Oxygen (MG/L)
DO(MG/L)
4
12
2
60
EKG
EKG
-0.5
4
0.01
200
CA ISE (MG/L)
CA(MG/L)
0
40000
1
180
NH4 ISE (MG/L)
NH4(MG/L)
0
18000
1
180
NO3 ISE (MG/L)
NO3(MG/L)
0
14000
1
180
CL ISE (MG/L)
CL(MG/L)
0
36000
1
180
Flow Rate (M/S)
FLOW RT (M/S)
0
4
1
180
Flow Rate (FT/S)
FLOW RT (FT/S)
0
13
1
180
Respiration (BPM)
RESP RT (BPM)
0
30
10
180
Turbidity (NTU)
TURBID (NTU)
0
50
1
180
C V Current (A)
CURRENT (A)
-0.6
0.6
0.1
180
C V Voltage (V)
VOLTAGE (V)
-6
6
0.1
180
Voltage L10 to 10 (V)
VOLTAGE (V)
-10
10
0.1
180
Voltage 0 to 5 (V)
VOLTAGE (V)
0
5
0.1
180
Hi Magnet Fld (MT)
MAGNET F(MT)
-0.32
0.32
0.05
180
Hi Magnet Fld (G)
MAGNET F(G)
L3.2
3.2
0.05
180
Lo Magnet Fld (MT)
MAGNET F(MT)
-10
5
0.05
180
Lo Magnet Fld (G)
MAGNET F(G)
-100
50
0.05
180
Barometer (KPA)
BARO(KPA)
80
110
600
180
Barometer (MMHG)
BARO (MMHG)
600
800
600
180
Sensor Name
CBL 2 Technical Reference
C-3
Page 63
Sensor Name
Short Name
Sample Interval
Y-Min
Y-Max
(in seconds)
No. Of Samples
Barometer (INHG)
BARO (INHG)
24
32
600
180
Barometer (MBAR)
BARO (MBAR)
810
1060
600
180
Relative Humidity (PCT)
REL HUM (PCT)
0
100
600
180
Oxygen Gas (PCT)
O2 GAS (PCT)
15
25
15
40
Oxygen Gas (PPT)
O2 GAS (PPT)
150
250
15
40
Custom 0 to 5 (V)
CUSTOM
0
5
1
180
Custom L10 to 10 (V)
CUSTOM
L10
10
1
180
Motion (M)
MOTION (M)
0
6
0.05
100
Motion (FT)
MOTION (FT)
1
20
0.05
100
Current Probe (A)
CURRENT (A)
L10
10
0.1
180
Resistance (OHMS)
RES (OHMS)
0
100000
0.1
180
The values in the table are valid for all calculator versions of DataMate except the TI-73, TI-82, TI-83, and TI-92. Because of memory limitations on these calculators, the number of data points is reduced. ♦
For the TI-73, the number of samples will be reduced if it exceeds 100 and multiple samples are set up.
♦
For the TI-82, all default number of samples will be limited to 99 points.
♦
For the TI-83, the number of samples will be reduced if it exceeds 200 points and multiple samples are set up.
C-4