CBL 2 Technical Reference: Appendix C: DataMate Sensor Setup Default Settings

Pages 60 to 63 of 63, from CBL 2 Technical Reference

The original document is the PDF (424 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Texas Instruments CBL2 System

Page 60

Appendix C: DataMate Sensor Setup Default Settings The table that follows shows the default settings used by the DataMate program. This sensor and calibration information applies only to Vernier and TI sensors. The use of other manufacturers’ sensors may require calibration or the input of that sensor’s calibration information into DataMate. Note: Default settings apply only when using a single sensor that is connected to Channel 1.

Short Name

Sensor Name

Sample Interval

Y-Min

Y-Max

(in seconds)

No. Of Samples

Dir connect Temp (C)

TEMP(C)

-15

110

1

180

Dir connect Temp (F)

TEMP(F)

0

250

1

180

Extra Long Temp (C)

TEMP(C)

-50

150

1

180

Stainless Temp (C)

TEMP(C)

-20

125

1

180

Stainless Temp (F)

TEMP(F)

-5

260

1

180

Thermocouple (C)

TEMP(C)

-200

1400

1

180 pH

PH

0

14

2

60

Conduct 200 (mS)

CONDUCT (MICS)

0

200

1

180

Conduct 100(MG/L)

TDS(MG/L)

0

100

1

180

Conduct 2000(mS)

CONDUCT (MICS)

0

2000

1

180

Conduct 1000(MG/L)

TDS(MG/L)

0

1000

1

180

Conduct 20000(mS)

CONDUCT (MICS)

0

20000

1

180

Conduct 10000(MG/L)

TDS(MG/L)

0

10000

1

180

Gas Pressure (KPA)

PRESS (KPA)

50

150

10

90

Gas Pressure (MMHG)

PRESS (MMHG)

400

1200

10

90

Gas Pressure (ATM)

PRESS (ATM)

0.5

1.6

10

90

Gas Pressure (INHG)

PRESS (INHG)

0

65

10

90

Pressure (KPA)

PRESS (KPA)

0

700

1

180

CBL 2 Technical Reference

C-1

Page 61

Sensor Name

Short Name

Sample Interval

Y-Min

Y-Max

(in seconds)

No. Of Samples

Pressure (ATM)

PRESS (ATM)

0

700

1

180

Pressure (MMHG)

PRESS (MMHG)

0

5200

1

180

Bio Pressure (KPA)

PRESS (KPA)

76

156

10

90

Bio Pressure (MMHG)

PRESS (MMHG)

550

1200

10

90

Bio Pressure (ATM)

PRESS (ATM)

0.75

1.6

10

90

Bio Pressure (INHG)

PRESS (INHG)

20

50

10

90

Dual R Force (5N)

FORCE(N)

-5

5

0.05

100

Dual R Force (10N)

FORCE(N)

-10

10

0.05

100

Dual R Force (50N)

FORCE(N)

-50

50

0.05

100

Student Force (N)

FORCE(N)

-40

10

0.05

100

EX Heart Rate (BPM)

Heart RT(BPM)

45

170

5

180

Heart Rate (BPM)

Heart RT(BPM)

45

170

5

180

25G Accel (M/S 2)

ACCEL (M/S 2)

-250

250

0.05

100

Low G Accel (M/S 2)

ACCEL (M/S 2)

-50

50

0.05

100

Colorimeter

ABSORBANCE

0

0.6

5

180

CO 2 Gas (PPM)

CO 2 GAS (PPM)

0

5000

10

30

CO 2 Gas (PPT)

CO 2 GAS (PPT)

0

5

10

30

CBL Microphone

MICROPHONE

0

5

1.00E-04

200

ULI Microphone

MICROPHONE

0

5

1.00E-04

200

MPLI Microphone

MICROPHONE

-5

5

1.00E-04

200

TI Light Sensor

LIGHT

0

1

0.05

180

C-2

CBL 2 Technical Reference

Page 62

Sample Interval

Short Name

Y-Min

Y-Max

(in seconds)

No. Of Samples

Light 600(LX)

LIGHT(LX)

0

600

0.05

180

Light 6000(LX)

LIGHT(LX)

0

6000

0.05

180

Light 150000(LX)

LIGHT(LX)

0

150000

0.05

180

D. Oxygen (MG/L)

DO(MG/L)

4

12

2

60

EKG

EKG

-0.5

4

0.01

200

CA ISE (MG/L)

CA(MG/L)

0

40000

1

180

NH4 ISE (MG/L)

NH4(MG/L)

0

18000

1

180

NO3 ISE (MG/L)

NO3(MG/L)

0

14000

1

180

CL ISE (MG/L)

CL(MG/L)

0

36000

1

180

Flow Rate (M/S)

FLOW RT (M/S)

0

4

1

180

Flow Rate (FT/S)

FLOW RT (FT/S)

0

13

1

180

Respiration (BPM)

RESP RT (BPM)

0

30

10

180

Turbidity (NTU)

TURBID (NTU)

0

50

1

180

C V Current (A)

CURRENT (A)

-0.6

0.6

0.1

180

C V Voltage (V)

VOLTAGE (V)

-6

6

0.1

180

Voltage L10 to 10 (V)

VOLTAGE (V)

-10

10

0.1

180

Voltage 0 to 5 (V)

VOLTAGE (V)

0

5

0.1

180

Hi Magnet Fld (MT)

MAGNET F(MT)

-0.32

0.32

0.05

180

Hi Magnet Fld (G)

MAGNET F(G)

L3.2

3.2

0.05

180

Lo Magnet Fld (MT)

MAGNET F(MT)

-10

5

0.05

180

Lo Magnet Fld (G)

MAGNET F(G)

-100

50

0.05

180

Barometer (KPA)

BARO(KPA)

80

110

600

180

Barometer (MMHG)

BARO (MMHG)

600

800

600

180

Sensor Name

CBL 2 Technical Reference

C-3

Page 63

Sensor Name

Short Name

Sample Interval

Y-Min

Y-Max

(in seconds)

No. Of Samples

Barometer (INHG)

BARO (INHG)

24

32

600

180

Barometer (MBAR)

BARO (MBAR)

810

1060

600

180

Relative Humidity (PCT)

REL HUM (PCT)

0

100

600

180

Oxygen Gas (PCT)

O2 GAS (PCT)

15

25

15

40

Oxygen Gas (PPT)

O2 GAS (PPT)

150

250

15

40

Custom 0 to 5 (V)

CUSTOM

0

5

1

180

Custom L10 to 10 (V)

CUSTOM

L10

10

1

180

Motion (M)

MOTION (M)

0

6

0.05

100

Motion (FT)

MOTION (FT)

1

20

0.05

100

Current Probe (A)

CURRENT (A)

L10

10

0.1

180

Resistance (OHMS)

RES (OHMS)

0

100000

0.1

180

The values in the table are valid for all calculator versions of DataMate except the TI-73, TI-82, TI-83, and TI-92. Because of memory limitations on these calculators, the number of data points is reduced. ♦

For the TI-73, the number of samples will be reduced if it exceeds 100 and multiple samples are set up.

♦

For the TI-82, all default number of samples will be limited to 99 points.

♦

For the TI-83, the number of samples will be reduced if it exceeds 200 points and multiple samples are set up.

C-4

CBL 2 Technical Reference