Page 303

Appendix C: Bar Code Settings Decoded (Intermec ISCP) EAN 8

Transmit Check Digit If the check digit is to be transmitted with the data, this parameter must be enabled. Add/Remove Data Refer to “Add/Remove Data” on page C-15 for details.

C.3.6

EAN 8 Enabled Set this parameter to on to enable “EAN 8”. Transmit Check Digit If the check digit is to be transmitted with the data, this parameter must be enabled. Convert To EAN 13 If this parameter is enabled, an EAN 8 bar code is converted to EAN 13. Add/Remove Data Refer to “Add/Remove Data” on page C-15 for details.

C.3.7

UPC A Enabled Set this parameter to on to enable “UPC A” bar code scanning recognition. Transmit Check Digit If the check digit is to be transmitted with the data, this parameter must be enabled. Transmit Number System If this parameter is enabled, the number system digit is transmitted with the decoded bar code data. Convert To EAN 13 If this parameter is enabled, a UPC A bar code is converted to EAN 13. Add/Remove Data Refer to “Add/Remove Data” on page C-15 for details.

Psion Teklogix 7535 G2 Hand-Held Computer User Manual

C-31

Page 304

Appendix C: Bar Code Settings Decoded (Intermec ISCP) UPC E Settings

C.3.8

UPC E Settings Enabled Set this parameter to on to enable “UPC E”. Enable UPC-E1 Set this parameter to on to allow “UPC-E1” (zero suppressed) bar code scans. Transmit Check Digit If the check digit is to be transmitted with the data, this parameter must be enabled. Transmit Number System If this parameter is enabled, the number system digit is transmitted with the decoded bar code data. Convert To UPC-A This parameter converts UPC E (zero suppressed) decoded data to UPC A format before transmission. After conversion, data follows UPC A format and is affected by UPC A programming selections (e.g. Check Digit). Add/Remove Data Refer to “Add/Remove Data” on page C-15 for details.

C.3.9

UPC/EAN Shared Settings The setting assigned to the “Addendum” parameter associated with this option is shared across all UPC and EAN bar codes. Addendum An addendum is a separate bar code, supplementary to the main bar code. This parameter provides two options: Not Required but Transmitted if Read or Required and Transmitted. • Double-tap on Addendum to display a dialog box listing your options. • Highlight an item, and tap on OK. When “Addendum” is set to Not Required but Transmitted if Read, the scanner searches for an addendum and if one exists, appends it to the main bar code. When the parameter is set to Required and Transmitted, the scanner does not accept the main bar code without an addendum.

C-32

Psion Teklogix 7535 G2 Hand-Held Computer User Manual

Page 305

Appendix C: Bar Code Settings Decoded (Intermec ISCP) Code 93

Addendum Add-on 2 And Addendum Add-on 5 Enabling these parameters sets the length of the addendum bar code to either 2 or 5 characters. Addendum Security If you tap on “Addendum Security”, a dialog box is displayed in which you can define the security level of add-on 2 or add-on 5 with a value from 0 to 100. As security levels increase, the scanner decode speed decreases. GTIN Compliant GTIN (global trade item number) processing transmits EAN 128 as the 14-character EAN/UCC GTIN. To use GTIN processing, you must activate the EAN 128 symbology. Important: When EAN 128 and GTIN processing are both activated, it is not possible to read normal EAN 128 Codes. Reading Range This parameter determines the reading distance from which a bar code can be successfully scanned. The default setting, Extended, allows for increased reading distance.

C.3.10 Code 93 Enabled Set this parameter to on to enable “Code 93”. Minimum Length Minimum lengths for the bar code can be set from 0 to 255. The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s). Length Restriction Refer to “Length Restriction” on page C-14 for details. Add/Remove Data Refer to “Add/Remove Data” on page C-15 for details.

Psion Teklogix 7535 G2 Hand-Held Computer User Manual

C-33

Page 306

Appendix C: Bar Code Settings Decoded (Intermec ISCP) Codabar

C.3.11 Codabar Enabled Set this parameter to on to enable “Codabar”. Start/Stop Transmit Codabar can use the following sets of characters as start and stop characters: a, b, c, d A, B, C, D a, b, c, d, /, t, n, *, e DC1, DC2, DC3, DC4 Thus, when a set is chosen, the first and last digits of a Codabar message must be one of those characters and the body of the message should not contain these characters. Setting this parameter to Not Transmitted strips the start and stop characters from this bar code. CLSI Library System When enabled, spaces are inserted after characters 1, 5, 10 in the 14-character label (used in the USA by libraries using the CLSI system). Check Digit Verification When enabled, this parameter checks the integrity of a symbol to ensure it complies with a specified algorithm - either USS (Uniform Symbology Specification) or OPCC (Optical Product Code Council). Transmit Check Digit If the check digit is to be transmitted with the data, this parameter must be enabled. Set Length L1, Set Length L2, And Set Length L3 Lengths for “Codabar” can be set from 0 to 255. The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s). Double-tapping on these parameters displays dialog boxes where you can define the code length that will be recognized by your scanner. Length Mode You can choose to set L1 as Minimum Length or L1,L2,L3 as Fixed Length.

C-34

Psion Teklogix 7535 G2 Hand-Held Computer User Manual

Page 307

Appendix C: Bar Code Settings Decoded (Intermec ISCP) MSI Plessey

Length Restriction Refer to “Length Restriction” on page C-14 for details. Add/Remove Data Refer to “Add/Remove Data” on page C-15 for details.

C.3.12 MSI Plessey Enabled Set this parameter to on to enable “MSI”. Enable Plessy Set this parameter to on to enable “Plessy”. Check Digit Verification The available options for this parameter are MOD 10 Check and Double MOD 10 Check. This parameter uses the specified algorithm of the option you've chosen to ensure the integrity of the symbol data before transmitting. If the data does not contain that algorithm, the data is not transmitted. Transmit Check Digit If the check digit is to be transmitted with the data, this parameter must be enabled. Plessy Transmit Check Digit If the check digit is to be transmitted with the Plessy data, this parameter must be enabled. Minimum Length Minimum lengths for the bar code can be set from 0 to 255. The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s). Plessy Minimum Length Minimum lengths for the Plessy bar code can be set from 0 to 255. The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s). Length Restriction Refer to “Length Restriction” on page C-14 for details. Add/Remove Data Refer to “Add/Remove Data” on page C-15 for details. Psion Teklogix 7535 G2 Hand-Held Computer User Manual

C-35

Page 308

Appendix C: Bar Code Settings Decoded (Intermec ISCP) Code 11

C.3.13 Code 11 Enabled Set this parameter to on to enable “Code 11”. Check Digit Verification The available options for this parameter are MOD 10 Check and Double MOD 10 Check.This parameter uses the specified algorithm of the option you've chosen to ensure the integrity of the symbol data before transmitting. If the data does not contain that algorithm, the data is not transmitted. Transmit Check Digit If the check digit is to be transmitted with the data, this parameter must be enabled. Minimum Length Minimum lengths for the bar code can be set from 0 to 255. The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s). Length Restriction Refer to “Length Restriction” on page C-14 for details. Add/Remove Data Refer to “Add/Remove Data” on page C-15 for details.

C.3.14 Interleaved 2 of 5 Enabled Set this parameter to on to enable “Interleaved 2 of 5”. Reading Range This parameter determines the reading distance from which a bar code can be successfully scanned. The default setting, Extended, allows for increased reading distance. Check Digit Verification The available options for this parameter are Disabled, MOD 10 Check and French CIP. “Check Digit Verification” uses the specified algorithm of the option you've chosen to ensure the integrity of the symbol data before transmitting. If the data does not contain that algorithm, the data is not transmitted.

C-36

Psion Teklogix 7535 G2 Hand-Held Computer User Manual

Page 309

Appendix C: Bar Code Settings Decoded (Intermec ISCP) Matrix 2 of 5

Note: French CIP (French pharmaceutical) is only used with bar codes containing 7 characters. Transmit Check Digit If the check digit is to be transmitted with the data, this parameter must be enabled. Set Length L1, Set Length L2, And Set Length L3 Lengths for “Interleaved 2 of 5” can be set from 0 to 255. The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s). Double-tapping on these parameters displays dialog boxes where you can define the code length that will be recognized by your scanner. Length Mode You can chose to set L1 as Minimum Length or L1,L2,L3 as Fixed Length. Length Restriction Refer to “Length Restriction” on page C-14 for details. Add/Remove Data Refer to “Add/Remove Data” on page C-15 for details.

C.3.15 Matrix 2 of 5 Enabled Set this parameter to on to enable “Matrix 2 of 5”. Minimum Length Minimum lengths for the bar code can be set from 0 to 255. The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s). Length Restriction Refer to “Length Restriction” on page C-14 for details. Add/Remove Data Refer to “Add/Remove Data” on page C-15 for details.

Psion Teklogix 7535 G2 Hand-Held Computer User Manual

C-37

Page 310

Appendix C: Bar Code Settings Decoded (Intermec ISCP) Discrete 2 of 5

C.3.16 Discrete 2 of 5 Enabled Set this parameter to on to enable “Discrete 2 of 5”. Standard 2 of 5 Format This parameter allows you to choose a standard format – either Identicon (6 start/stop bars) or Computer Identics (4 start/stop bars). Check Digit Verification The available options for this parameter are Disabled and MOD 10 Check. “Check Digit Verification” uses the specified algorithm of the option you've chosen to ensure the integrity of the symbol data before transmitting. If the data does not contain that algorithm, the data is not transmitted. Transmit Check Digit If the check digit is to be transmitted with the data, this parameter must be enabled. Set Length L1, Set Length L2, And Set Length L3 Lengths for “Discrete 2 of 5” can be set from 0 to 255. The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s). Double-tapping on these parameters displays dialog boxes where you can define the code length that will be recognized by your scanner. Length Mode You can chose to set L1 as Minimum Length or L1,L2,L3 as Fixed Length. Length Restriction Refer to “Length Restriction” on page C-14 for details. Add/Remove Data Refer to “Add/Remove Data” on page C-15 for details.

C.3.17 Telepen Enabled Set this parameter to on to enable “Telepen”.

C-38

Psion Teklogix 7535 G2 Hand-Held Computer User Manual

Page 311

Appendix C: Bar Code Settings Decoded (Intermec ISCP) RSS Code (Reduced Space Symbology)

Format This parameter allows you to set the bar code character format to either ASCII or Numeric. Minimum Length Minimum lengths for the bar code can be set from 0 to 255. The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s). Length Restriction Refer to “Length Restriction” on page C-14 for details. Add/Remove Data Refer to “Add/Remove Data” on page C-15 for details.

C.3.18 RSS Code (Reduced Space Symbology) Enable Setting this parameter to on enables “RSS Code” scanning capability. Enable RSS-14 RSS-14 code can be either purely linear or split in half with one half stacked on top of the other half. Stacking the code reduces the bar code length, and providing the nominal height of the code is maintained, it can be omni-directionally scanned. Enable RSS Limited ‘RSS-Limited” is restricted, in that it can only encode 14 digit GTINs (global trade item numbers) that begin with either 0 or 1. It is not stackable and is not designed to be read omni-directionally. Enable RSS Expanded ‘RSS Expanded” uses the same application identifiers as UCC/EAN-128 codes but they can be split into sections and stacked several rows high, reducing the length of the symbol, while increasing the capacity of data that can be stored. “RSS Expanded” code can be omni-directionally scanned. Length Restriction Refer to “Length Restriction” on page C-14 for details. Add/Remove Data Refer to “Add/Remove Data” on page C-15 for details. Psion Teklogix 7535 G2 Hand-Held Computer User Manual

C-39

Page 312

Appendix C: Bar Code Settings Decoded (Intermec ISCP) Composite

C.3.19

Composite Important: To successfully read this type of bar code, the two types of symbologies included in a composite bar code must be enabled. In addition, “Center Bar Code Only” must be disabled (see page C-43). A composite symbol includes multi-row 2D components making it compatible with linear and area CCD scanners along with linear and rastering laser scanners. The options available for this parameter represent multi-level components of a composite symbol. Enable CC-C And Enable CC-AB To activate these components, set these parameters to on. Linear Transmission Only When Linear Transmission Only is enabled, only the linear code portion of the composite bar code is transmitted when scanned. UPC-EAN Composite Message This option allows you to choose how UPC-EAN shared bar codes are transmitted: Always Linked, Never Linked or Auto-discriminate.

C.3.20

TLC-39 Enabled This composite component integrates MicroPDF417 with the linear Code 39 symbol. Setting this parameter to on enables this parameter. Linear Transmission Only When Linear Transmission Only is enabled, only the linear portion of the composite bar code is transmitted when scanned. Security Level This parameter is used to differentiate between TLC-39 and standard Code 39. Tapping on Security Level displays a dialog box in which you can assign a value from 0 to 100. The higher the value assigned, the lower the decode rate. Length Restriction Refer to “Length Restriction” on page C-14 for details.

C-40