Appendix C: Bar Code Settings Decoded (Internal) Scanners MSI Plessey
Add/Remove Data Refer to “Add/Remove Data” on page C-15 for details.
C.2.14 MSI Plessey Enabled Set this parameter to on to enable “MSI Plessey”. Set Length L1 And Set Length L2 Lengths for “MSI Plessey” can be set for Any length, Length within a range, One discrete length or Two discrete lengths. The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s). Double-tapping on this parameter displays a dialog box labelled Set Code Lengths where you can define the code length that will be recognized by your scanner. Choosing One discrete length allows you to decode only those codes containing a selected length. Choosing Two discrete lengths allows you to decode only those codes containing two selected lengths. Length within a range allows you to decode a code type within a specified range from 6 to 55. Check Digits Double-tapping on this parameter displays a dialog box in which you can choose One or Two check digit(s). If this parameter is set to One, it is assumed that the last digit is a check digit. If “Check Digits” is set to Two, it is assumed that the last two digits are check digits. Note: If Two check digits is selected, an MSI Plessey “Check Digit Algorithm” must also be selected. See below for details. Transmit Check Digit If this parameter is enabled, the check digit is included with the bar code data. Check Digit Algorithm When the Two MSI Plessey check digits option is selected, an additional verification is required to ensure integrity. Double-tapping on this parameter displays a dialog box in which you can choose the algorithm to be used: MOD 10/MOD 11 or MOD 10/MOD 10. Length Restriction Refer to “Length Restriction” on page C-14 for details. Psion Teklogix 7535 G2 Hand-Held Computer User Manual
C-21
Page 294
Appendix C: Bar Code Settings Decoded (Internal) Scanners Interleaved 2 of 5
Add/Remove Data Refer to “Add/Remove Data” on page C-15 for details.
C.2.15 Interleaved 2 of 5 Enabled Set this parameter to on to enable “Interleaved 2 of 5”. Set Length L1 And Set Length L2 Lengths for “Interleaved 2 of 5” can be set for Any length, Length within a range, One discrete length or Two discrete lengths. The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s). Double-tapping on this parameter displays a dialog box labelled Set Code Lengths where you can define the code length that will be recognized by your scanner. Choosing One discrete length allows you to decode only those codes containing a selected length. Choosing Two discrete lengths allows you to decode only those codes containing two selected lengths. Length within a range allows you to decode a code type within a specified range from 4 to 14. Check Digit Verification When enabled, this parameter checks the integrity of an I 2 of 5 symbol to ensure it complies with a specified algorithm: either USS (Uniform Symbology Specification) or OPCC (Optical Product Code Council). Transmit Check Digit If this parameter is enabled, the check digit is included with the bar code data. Convert To EAN 13 If this parameter is enabled, an I 2 of 5 bar code is converted to EAN 13. Length Restriction Refer to “Length Restriction” on page C-14 for details. Add/Remove Data Refer to “Add/Remove Data” on page C-15 for details.
C-22
Psion Teklogix 7535 G2 Hand-Held Computer User Manual
Page 295
Appendix C: Bar Code Settings Decoded (Internal) Scanners Discrete 2 of 5
C.2.16 Discrete 2 of 5 Enabled Set this parameter to on to enable “Discrete 2 of 5”. Set Length L1 And Set Length L2 Lengths for “Discrete 2 of 5” can be set for Any length, Length within a range, One discrete length or Two discrete lengths. The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s). Double-tapping on this parameter displays a dialog box labelled Set Code Lengths where you can define the code length that will be recognized by your scanner. Choosing One discrete length allows you to decode only those codes containing a selected length. Choosing Two discrete lengths allows you to decode only those codes containing two selected lengths. Length within a range allows you to decode a code type within a specified range from 1 to 12. Length Restriction Refer to “Length Restriction” on page C-14 for details. Add/Remove Data Refer to “Add/Remove Data” on page C-15 for details.
C.2.17 RSS Code (Reduced Space Symbology) Enable Setting any of these parameters to on enables “2D RSS Code” scanning capability. Enable RSS-14 (Reduced Space Symbology) RSS-14 code can be either purely linear or split in half with one half stacked on top of the other half. Stacking the code reduces the bar code length, and providing the nominal height of the code is maintained, it can be omni-directionally scanned. Enable RSS Limited “RSS-Limited” is restricted, in that it can only encode 14 digit GTINs (global trade item number) that begin with either a 0 or a 1. It is not stackable and is not designed to be read omni-directionally.
Psion Teklogix 7535 G2 Hand-Held Computer User Manual
C-23
Page 296
Appendix C: Bar Code Settings Decoded (Internal) Scanners Composite
Enable RSS Expanded “RSS Expanded” uses the same application identifiers as UCC/EAN-128 codes but it can be split into sections and stacked several rows high, reducing the length of the symbol, while increasing the capacity of data that can be stored. “RSS Expanded” code can be omnidirectionally scanned. Length Restriction Refer to “Length Restriction” on page C-14 for details. Add/Remove Data Refer to “Add/Remove Data” on page C-15 for details.
C.2.18 Composite Important: To successfully read this type of bar code, the two types of symbologies included in a composite bar code must be enabled. In addition, “Center Bar Code Only” must be disabled (see page C-43). A composite symbol includes multi-row 2D components making it compatible with linear and area CCD scanners along with linear and rastering laser scanners. The options available for this parameter represent multi-level components of a composite symbol. Enable CC-C And Enable CC-AB To activate these components, set the parameters to on. Enable TLC-39 This composite component integrates MicroPDF417 with the linear code. Setting this parameter to on enables this parameter.
C.2.19 PDF-417 Enabled Setting this parameter to on enables PDF-417 two dimensional (2D) coding. Length Restriction Refer to “Length Restriction” on page C-14 for details.
C-24
Psion Teklogix 7535 G2 Hand-Held Computer User Manual
Page 297
Appendix C: Bar Code Settings Decoded (Internal) Scanners Micro PDF-417
Add/Remove Data Refer to “Add/Remove Data” on page C-15 for details.
C.2.20 Micro PDF-417 Enabled Setting this parameter to on enables “2D Micro PDF-417” bar code scanning. Micro PDF417 is a multi-row symbology that is useful for applications requiring greater area efficiency but lower data capacity than PDF-417. Code 128 Emulation When this parameter is enabled, the scanner transmits data from certain Micro PDF-417 symbols as if it was encoded in Code 128 symbols. If Code 128 Emulation is enabled, the following Micro PDF-417 symbols are transmitted with one of the following prefixes: ]C1 if the first codeword is 903-907, 912, 914, 915 ]C2 if the first codeword is 908 or 909 ]C0 if the first codeword is 910 or 911 If Code 128 Emulation is set to off, the Micro PDF-417 symbols are transmitted with one of the following prefixes: ]L3 if the first codeword is 903-907, 912, 914, 915 ]L4 if the first codeword is 908 or 909 ]L5 if the first codeword is 910 or 911 Length Restriction Refer to “Length Restriction” on page C-14 for details. Add/Remove Data Refer to “Add/Remove Data” on page C-15 for details.
Psion Teklogix 7535 G2 Hand-Held Computer User Manual
C-25
Page 298
Appendix C: Bar Code Settings Decoded (Intermec ISCP) Decoded (ISCP) Options
C.3
Decoded (Intermec ISCP)
•
C.3.1
Tap on the Scanner drop-down menu, and choose Decoded (Intermec ISCP).
Decoded (ISCP) Options Laser On Time The value assigned to this parameter determines how long the laser will remain on when the scan button or trigger is pressed. Double-tapping on this parameter displays a dialog box in which you can enter a value between 1 and 10 seconds.
C.3.2
Decoded (ISCP) Advanced Options Continuous Scan Mode Setting this parameter to on keeps the laser on and continuously decoding as long as the scanner button is pressed and held down. Minimum Cancel Time The value assigned to this parameter determines the time delay before the scanner is turned off, once the scanner trigger or button is released. This gives the scanner a minimum amount of time to complete its current decode before the scan is cancelled when you quickly trigger on/off.
C-26
Psion Teklogix 7535 G2 Hand-Held Computer User Manual
Page 299
Appendix C: Bar Code Settings Decoded (Intermec ISCP) Code 39
Low Power Timeout To extend laser life, you can select the time the scanner remains active following a successful decode. The scanner wakes from low power mode when a bar code is scanned - a successful decode restores normal blinking. When you double-tap on this parameter, a dialog box is displayed in which you can choose a value of 30 sec, 1 min, 2 min, or 3 min. Note: This parameter is only used if the Trigger Mode has been set to Continuous On and the unit is mounted in a fixed position; otherwise, ‘Low Power Timeout’ is not used. Parameter Scanning Setting this parameter to Enabled allows decoding of parameter bar codes. Same Read Validate The data is only transmitted after repeated reads give the same result. The value assigned at this parameter determines the number of reads required, from 0 to 10 times. Same Read Timeout Prevents the same bar code from being read more than once. The value assigned determines after what time period the scanner will timeout, from 0 to 2550 msec. Diff Read Timeout Prevents unwanted reading of other bar codes on the same label. The value assigned determines after what time period the scanner will timeout, from 0 to 2550 msec. Add AIM ID Prefix The AIM ID (Association for Automatic Identification and Mobility) is an international bar code identifier. When this parameter is enabled, the AIM ID is inserted at the beginning of the decoded bar code.
C.3.3
Code 39 Enable Setting this parameter to on enables “Code 39”.
Psion Teklogix 7535 G2 Hand-Held Computer User Manual
C-27
Page 300
Appendix C: Bar Code Settings Decoded (Intermec ISCP) Code 39
Full ASCII If this parameter is enabled, the characters +, %, and / are used as escape characters. The combination of an escape character and the next character is converted to an equivalent ASCII character. Reading Range Determines the reading distance from which a bar code can be successfully scanned. The default setting, Extended, allows for increased reading distance. Start/Stop Transmit Setting this parameter to on enables the transmission of start and stop characters, which are usually not transmitted. Code 39 can start and end with either a * or a $ character (see also the next parameter). Accepted Start Char This parameter allows you the option of using one of the two start/stop characters or both ($ char, * char, $ and * char). Check Digit Verification Uses the specified algorithm of the option you've chosen to ensure the integrity of the symbol data before transmitting. If the data does not contain that algorithm, the data is not transmitted. The available options are: Disabled, MOD 43 Check, French CIP, or Italian CIP. Note: French CIP (French pharmaceutical) is only used with bar codes containing 7 characters. Italian CIP (Italian pharmaceutical) is also known as Code 32. It is transmitted as a standard Code 39 if checksum is not validated. Transmit Check Digit If the check digit is to be transmitted with the data, this parameter must be enabled. Minimum Length Minimum lengths for the bar code can be set from 0 to 255. The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s). Length Restriction Refer to “Length Restriction” on page C-14 for details.
C-28
Psion Teklogix 7535 G2 Hand-Held Computer User Manual
Page 301
Appendix C: Bar Code Settings Decoded (Intermec ISCP) Code 128
Add/Remove Data Refer to “Add/Remove Data” on page C-15 for details.
C.3.4
Code 128 Enabled Setting this parameter to on enables “Code 128”. GS1-128 “GS1-128” is the GS1 implementation of the Code 128 barcode specification. The former correct name was UCC/EAN-128. GS1-128 Identifier “GS1-128 Identifier” allows the AIM ID " ]C1" for EAN 128 to be transmitted or removed. By default, this identifier is transmitted if EAN 128 is enabled. GTIN Compliant GTIN (global trade item number) processing transmits EAN 128 as the 14-character EAN/UCC GTIN. To use GTIN processing, you must activate the EAN 128 symbology. Important: When EAN 128 and GTIN processing are both activated, it is not possible to read normal EAN 128 Codes. FNC1 Conversion “FNC1 Conversion” allows the FNC1 character to be converted to another character for applications that cannot use the default <GS> Group Separator or hex (1d). Double-tapping on this option displays a dialog box listing the allowable range: 0 to 255. Enable ISBT 128 To successfully scan this type of bar code (International Society of Blood Transfusion), this option must be set to on. If you enable this type of bar code, Code 128/EAN 128 is deactivated to avoid any confusion. ISBT Concat Transmit The codes are not concatenated by default. You need to choose one of the options provided for this parameter to send concatenated code. Choosing Only Concatenated Codes transmits only concatenated codes - single codes will not be transmitted. Choosing Concatenated or Single transmits single codes or concatenated codes. If only one code of a pair is read, that Psion Teklogix 7535 G2 Hand-Held Computer User Manual
C-29
Page 302
Appendix C: Bar Code Settings Decoded (Intermec ISCP) EAN 13 code will be transmitted as a single code. If both codes in a pair are detected, they will be concatenated provided that “ISBT Concat Any Pair” (see below) is enabled. ISBT Concat Any Pair Enabling this parameter causes all code pairs that can be, to be concatenated even if they do not comply with Section 4.1 of the “ISBT 128 Bar Code Symbology and Application Specification for Labeling of Whole Blood and Blood Components” (June 2000, Version 1.2.1). Reading Range Determines the reading distance from which a bar code can be successfully scanned. The default setting, Extended, allows for increased reading distance. Check Digit Verification The available options for this parameter are Disabled or French CIP. This parameter uses the specified algorithm of the option you've chosen to ensure the integrity of the symbol data before transmitting. If the data does not contain that algorithm, the data is not transmitted. Note: French CIP (French pharmaceutical) is only used with bar codes containing 7 characters. Minimum Length Minimum lengths for the bar code can be set from 0 to 255. The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s). Length Restriction Refer to “Length Restriction” on page C-14 for details. Add/Remove Data Refer to “Add/Remove Data” on page C-15 for details.
C.3.5
EAN 13 Enabled Set this parameter to on to enable “EAN 13”. ISBN Conversion When this parameter (International Standard Book Number) is enabled, the first 3 characters (‘978’) are ignored and the checksum (0.9, ‘X’) is calculated on the remaining characters.