Page 283

Appendix C: Bar Code Settings Decoded (Internal) Scanners Decoded (Internal) 2D Scanning Options

Scan Angle This option allows you to choose from two scan angles: Normal Angle or Alternate Angle. Choosing Normal Angle allows the normal operation for scanning long range and short range. Choosing Alternate Angle widens the beam to allow scanning of long bar codes at short range but at the cost of long range scanning.

C.2.3

Decoded (Internal) 2D Scanning Options Scanning Mode When you double-tap on this parameter, a dialog box is displayed in which you can choose one of the following scanning modes: Smart Raster, Always Raster, Programmable Raster, Slab Pattern, Cyclone Pattern, or Semi-Omni Pattern. Raster Height And Raster Expand Rate These parameters determine the laser pattern’s height and rate of expansion. Note: These parameters are only used when either Programmable Raster or Always Raster is assigned to the “2D Scanning Mode” parameter. “2D Raster Height” and “2D Raster Expand Rate” are intended for very specific applications and are usually not required for normal scanning purposes. Double-tapping on these parameters displays dialog boxes in which you can enter a value from 1 to 15.

C.2.4

Decoded (Internal) Data Options Transmit Code ID Char A code ID character identifies the scanned bar code type. In addition to any single character prefix already selected, the code ID character is inserted between the prefix and the decoded symbol. When you double-tap on this parameter, a dialog box is displayed in which you can choose a transmit code: None, AIM or Symbol. Scan Data Format This parameter allows you to change the scan data transmission format. Double-tapping on Scan Data Format displays the following options from which you can choose a data format: data (as-is), data [S1], data [S2], data [S1][S2], [P] data, [P] data [S1], [P] data [S2] and [P] data [S1][S2]. Psion Teklogix 7535 G2 Hand-Held Computer User Manual

C-11

Page 284

Appendix C: Bar Code Settings Decoded (Internal) Scanners Code 39

Prefix [P], Suffix [S1] And Suffix [S2] A prefix and/or one or two suffixes may be appended to scan data for use in data editing. When you double-tap on these parameters, dialog boxes are displayed in which you can enter a value from 0 to 255. Delete Char Set ECIs Setting this parameter to on enables the scanner to delete any escape sequences representing Character Set ECIs (Extended Channel Interpretations [also known as GLIs]) from its buffer before transmission. When this parameter is enabled, the scanner transmits data from PDF417 and MicroPDF417 bar codes containing Character Set ECIs, even when the ECI Protocol is disabled. ECI Decoder Setting this parameter to on enables the scanner to interpret any Extended Channel Interpretations (ECIs) supported by the scanner. This parameter has no effect on symbols that were not encoded using ECIs. If this parameter is set to off and a symbol that was encoded using an ECI escape is scanned, the scanner transmits the ECI escape followed by the uninterpreted data.

C.2.5

Code 39 Enabled Setting this parameter to on enables “Code 39”. Enable Trioptic Code 39 Note: “Trioptic Code 39” and “Full ASCII” should not be enabled simultaneously. The scanner does not automatically discriminate between these two symbologies. Trioptic Code 39 symbols always contain six characters. Setting this parameter to on allows this type of symbology to be recognized. Convert To Code 32 Note: “Code 39” must be enabled in order for this parameter to function. Setting this parameter to on allows the scanner to convert the bar code from “Code 39” to “Code 32”.

C-12

Psion Teklogix 7535 G2 Hand-Held Computer User Manual

Page 285

Appendix C: Bar Code Settings Decoded (Internal) Scanners Code 39

Code 32 Prefix Note: “Convert to Code 32” must be enabled in order for this parameter to function. When this parameter is enabled, the prefix character “A” is added to all “Code 32” bar codes. Set Length L1 And Set Length L2 Lengths for “Code 39” can be set for Any length, Length within a range, One discrete length or Two discrete lengths. The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s). Double-tapping on these parameters displays dialog boxes labelled Set Code Lengths where you can define the code length that will be decoded by your scanner.

Choosing One discrete length allows you to decode only those codes containing a selected length. Choosing Two discrete lengths allows you to decode only those codes containing two selected lengths. Length within a range allows you to decode a code type within a specified range from 2 to 55. Check Digit Verification When this parameter is enabled, the integrity of a “Code 39” symbol is checked to ensure that it complies with specified algorithms. Note: Only those “Code 39” symbols that include a MOD 43 check digit are decoded when this parameter is enabled. Psion Teklogix 7535 G2 Hand-Held Computer User Manual

C-13

Page 286

Appendix C: Bar Code Settings Decoded (Internal) Scanners Code 39

Transmit Check Digit If the check digit is to be transmitted with the data, this parameter must be enabled. Full ASCII If this parameter is enabled, the characters +, %, and / are used as escape characters. The combination of an escape character and the next character is converted to an equivalent ASCII character. Decode Performance If this parameter is enabled, one of three decode levels can be chosen in the Decode Performance Level parameter. Decode Perf. Level This parameter provides three levels of decode performance or “aggressiveness” for Code 39 symbols. Increasing the performance level reduces the amount of required bar code orientation - this is useful when scanning very long and/or truncated bar codes. Keep in mind that increased levels reduce decode security. When you double-tap on this parameter, a dialog box is displayed in which you can enter a decode performance level of between 1 and 3. Length Restriction The parameters in this sub-menu allow you to define the length of the bar codes that will be decoded using either the Field Size parameter or the Minimum Size and Maximum Size parameters (see below). The order of operation to either match the Field Size or determine if the length falls between the Minimum Size and Maximum Size is as follows: • • •

Strip the leading and trailing characters. Add the prefix and suffix characters. Count the number of characters remaining to either match the field size or determine if the length falls between the minimum and maximum size.

Field Size

When a value is assigned for this parameter, only bar codes that match the field size exactly can be transmitted. If a value is assigned to this parameter, a Minimum Size and Maximum Size value is not required.

C-14

Psion Teklogix 7535 G2 Hand-Held Computer User Manual

Page 287

Appendix C: Bar Code Settings Decoded (Internal) Scanners Code 128

Minimum Size And Maximum Size

When a value is assigned to these parameters, only bar code lengths that fall between the minimum and maximum value can be decoded. If values are assigned to these parameters, a Field Size value is not required. Add/Remove Data Prefix Char

This character, if non-zero, is added before a successfully decoded bar code. Press the key you want to insert in the dialog box attached to this parameter. The ASCII/Unicode key value of the keypress is displayed. Suffix Char

This character, if non-zero, is added after a successfully decoded bar code. Press the key you want to insert in the dialog box attached to this parameter. The ASCII/Unicode key value of the keypress is displayed. Strip Leading

This parameter determines the number of characters that will be removed from the beginning of the bar code before the prefix character is added. Note: For Code 39 bar codes, the “AIAG Strip” is performed before the “Strip Leading”. Strip Trailing

The value entered in this parameter determines the number of characters that will be removed from the end of the bar code before the suffix character is added.

C.2.6

Code 128 Enabled Set this parameter to on to enable “Code 128”. Enable GS1-128/GS1 US Previously UPC/EAN and UCC, the GS1-128/GS1 US types of bar code include group separators and start codes. Enable ISBT 128 To successfully scan this type of bar code, this option must be set to on.

Psion Teklogix 7535 G2 Hand-Held Computer User Manual

C-15

Page 288

Appendix C: Bar Code Settings Decoded (Internal) Scanners EAN 13

Decode Performance If this parameter is set to on, one of three decode levels assigned to the Decode Performance Level parameter can be selected. Decode Perf. Level This parameter provides three levels of decode performance or “aggressiveness” for Code 128 symbols. Increasing the performance level reduces the amount of required bar code orientation, allowing you to scan at an angle horizontal to the bar code. This is useful when scanning very long and/or truncated bar codes. Keep in mind that increased levels reduce decode security. There is a limitation that it can only be used with one fixed length. When you double-tap on this parameter, a dialog box is displayed in which you can enter a decode performance level of between 1 and 3. Length Restriction Refer to “Length Restriction” on page C-14 for details. Add/Remove Data Refer to “Add/Remove Data” on page C-15 for details.

C.2.7

EAN 13 Enabled Set this parameter to on to enable “EAN 13”. Add/Remove Data Refer to “Add/Remove Data” on page C-15 for details.

C.2.8

EAN 8 Enabled Set this parameter to on to enable “EAN 8”. EAN-8 Zero Extend When this parameter is enabled, five leading zeros are added to decoded EAN-8 symbols, making them compatible in format to EAN-13 symbols. Disabling this parameter returns EAN-8 symbols to their normal format.

C-16

Psion Teklogix 7535 G2 Hand-Held Computer User Manual

Page 289

Appendix C: Bar Code Settings Decoded (Internal) Scanners UPC A

Add/Remove Data Refer to “Add/Remove Data” on page C-15 for details.

C.2.9

UPC A Enabled Set this parameter to on to enable “UPC A”. UPC-A, Check Digit If you enable this parameter, the check digit is included with the decoded bar code data. UPC-A, Preamble When you double-tap on this parameter, a dialog box is displayed where you can choose one of three options for lead-in characters for UPC-A symbols transmitted to the host device: System Char - system character transmitted with the data, Country Code and System Char - both the country code (“0” for USA) and system character are transmitted with the data, or None - no preamble is transmitted. The lead-in characters are considered part of the symbol. Add/Remove Data Refer to “Add/Remove Data” on page C-15 for details.

C.2.10 UPC E Enabled UPC-E Set this parameter to on to allow “UPC E” bar code scans. Enabled UPC-E1 Set this parameter to on to allow “UPC-E1” (zero suppressed) bar code scans. UPC-E And UPC-E1 Check Digit If you enable one or both of these parameters, a check digit is included with the decoded bar code data.

Psion Teklogix 7535 G2 Hand-Held Computer User Manual

C-17

Page 290

Appendix C: Bar Code Settings Decoded (Internal) Scanners UPC/EAN Shared Settings

UPC-E And UPC-E1 Preamble When you double-tap on one of these parameters, a dialog box is displayed where you can choose one of three options for lead-in characters for UPC-E and UPC-E1 symbols transmitted to the host device: System Char - system character transmitted with the data, Country Code and System Char - both the country code (“0” for USA) and system character are transmitted with the data, or None - no preamble is transmitted. The lead-in characters are considered part of the symbol. Conv. UPC-E To UPC-A This parameter converts UPC-E (zero suppressed) decoded data to UPC-A format before transmission. After conversion, data follows UPC-A format and is affected by UPC-A programming selections (e.g., Preamble, Check Digit). Conv. UPC-E1 To UPC-A This parameter converts UPC-E1 (zero suppressed) decoded data to UPC-A format before transmission. After conversion, data follows UPC-A format and is affected by UPC-A programming selections (e.g., Preamble, Check Digit). Add/Remove Data Refer to “Add/Remove Data” on page C-15 for details.

C.2.11 UPC/EAN Shared Settings The parameters you set here are a shared across all available UPC and EAN bar codes. Enable Bookland EAN Setting this parameter to on allows your scanner to recognize Bookland EAN bar codes. Supplementals Supplementals are additionally appended characters (2 or 5). Double-tapping this parameter displays a list of options. If Ignore is chosen, UPC/EAN is decoded and the supplemental characters are ignored. If Decode is chosen, UPC/EAN symbols are decoded with supplementals. Autodiscriminate works in conjunction with the Supp. Redundancy parameter.

C-18

Psion Teklogix 7535 G2 Hand-Held Computer User Manual

Page 291

Appendix C: Bar Code Settings Decoded (Internal) Scanners Code 93

Supp. Redundancy With “Autodiscriminate” selected in the Supplementals parameter, Supp. Redundancy adjusts the number of times a symbol without supplementals is decoded before transmission. When you double-tap on this parameter, a dialog is displayed in which you can enter a value between 2 and 20. A value of 5 or above is recommended when Autodiscriminate is selected and you are decoding a mix of UPC/EAN symbols with and without supplementals. Security Level This parameter controls the tolerance for decoding edge-to-edge UPC/EAN bar codes. Double-tapping on this parameter displays a dialog box in which you can choose a level from 0 to 3. Lower values have a lower tolerance for misreads, but they also increase the time it takes to decode the bar code. Linear Decode (Model SE2223) Linear Decode applies to code types containing two adjacent blocks (e.g., UPC-A, EAN-8, EAN-13). When enabled (set to on), a bar code is transmitted only when both the left and right blocks are successfully decoded within one laser scan. This option should be enabled when bar codes are in proximity to each other. 2D UPC Half Block Stitching (Model SE2223) Setting this parameter to on enables “UPC Half Block Stitching” for the SE2223 omnidirectional engine only.

C.2.12 Code 93 Enabled Set this parameter to on to enable “Code 93”, or off to disable it. Set Length L1 And Set Length L2 Lengths for “Code 93” can be set for Any Length, Length within a range, One discrete length or Two discrete lengths. The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s). Double-tapping on this parameter displays a dialog box labelled Set Code Lengths where you can define the code length that will be recognized by your scanner. Choosing One discrete length allows you to decode only those codes containing a selected length. Choosing Two discrete lengths allows you to decode only those codes containing two

Psion Teklogix 7535 G2 Hand-Held Computer User Manual

C-19

Page 292

Appendix C: Bar Code Settings Decoded (Internal) Scanners Codabar selected lengths. Length within a range allows you to decode a code type within a specified range from 4 to 55. Length Restriction Refer to “Length Restriction” on page C-14 for details. Add/Remove Data Refer to “Add/Remove Data” on page C-15 for details.

C.2.13 Codabar Enabled Set this parameter to on to enable “Codabar”. Set Length L1 And Set Length L2 Lengths for “Codabar” can be set for Any length, Length within a range, One discrete length or Two discrete lengths. The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s). Double-tapping on this parameter displays a dialog box labelled Set Code Lengths where you can define the code length that will be recognized by your scanner. Choosing One discrete length allows you to decode only those codes containing a selected length. Choosing Two discrete lengths allows you to decode only those codes containing two selected lengths. Length within a range allows you to decode a code type within a specified range from 5 to 55. CLSI Editing When enabled, this parameter strips the start and stop characters and inserts a space after the first, fifth, and tenth characters of a 14-character Codabar symbol. Note: Symbol length does not include start and stop characters. NOTIS Editing When enabled, this parameter strips the start and stop characters from decoded Codabar symbol. Length Restriction Refer to “Length Restriction” on page C-14 for details.

C-20

Psion Teklogix 7535 G2 Hand-Held Computer User Manual