Page 273
APPENDIX C BAR CODE SETTINGS C.1 Bar Code Settings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 C.1.1 Scanner Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 C.1.2 Restoring Default Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 C.2 Decoded (Internal) Scanners . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 C.2.1 Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 C.2.2 Decoded (Internal) Advanced Options . . . . . . . . . . . . . . . . . . . . . 9 C.2.3 Decoded (Internal) 2D Scanning Options . . . . . . . . . . . . . . . . . . .11 C.2.4 Decoded (Internal) Data Options . . . . . . . . . . . . . . . . . . . . . . . .11 C.2.5 Code 39 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 C.2.6 Code 128 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 C.2.7 EAN 13 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 C.2.8 EAN 8. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 C.2.9 UPC A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 C.2.10 UPC E . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 C.2.11 UPC/EAN Shared Settings . . . . . . . . . . . . . . . . . . . . . . . . . 18 C.2.12 Code 93 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 C.2.13 Codabar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 C.2.14 MSI Plessey . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 C.2.15 Interleaved 2 of 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 C.2.16 Discrete 2 of 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 C.2.17 RSS Code (Reduced Space Symbology) . . . . . . . . . . . . . . . . . . 23 C.2.18 Composite . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 C.2.19 PDF-417 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 C.2.20 Micro PDF-417 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 C.3 Decoded (Intermec ISCP) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 C.3.1 Decoded (ISCP) Options . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 C.3.2 Decoded (ISCP) Advanced Options . . . . . . . . . . . . . . . . . . . . . 26 C.3.3 Code 39 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 C.3.4 Code 128 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 Psion Teklogix 7535 G2 Hand-Held Computer User Manual
C-1
Page 274
Appendix C: Bar Code Settings
C.3.5 EAN 13 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 C.3.6 EAN 8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 C.3.7 UPC A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 C.3.8 UPC E Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 C.3.9 UPC/EAN Shared Settings . . . . . . . . . . . . . . . . . . . . . . . . . . 32 C.3.10 Code 93. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 C.3.11 Codabar. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 C.3.12 MSI Plessey . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 C.3.13 Code 11. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 C.3.14 Interleaved 2 of 5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 C.3.15 Matrix 2 of 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 C.3.16 Discrete 2 of 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 C.3.17 Telepen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 C.3.18 RSS Code (Reduced Space Symbology). . . . . . . . . . . . . . . . . . . 39 C.3.19 Composite . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 C.3.20 TLC-39 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 C.3.21 PDF-417 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 C.3.22 Micro PDF-417. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 C.3.23 Codablock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42 C.4 Imager . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42 C.4.1 Imager Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42 C.4.2 Imager Advanced Options. . . . . . . . . . . . . . . . . . . . . . . . . . . 44 C.4.3 Code 39 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46 C.4.4 Code 128. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 C.4.5 EAN 13 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 C.4.6 EAN 8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48 C.4.7 UPC A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48 C.4.8 UPC E . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48 C.4.9 Code 93 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49 C.4.10 Codabar. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49 C.4.11 Interleaved 2 of 5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49 C.4.12 RSS Code (Reduced Space Symbology). . . . . . . . . . . . . . . . . . . 50 C.4.13 Composite . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 C.4.14 PDF-417 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 C.4.15 Micro PDF-417. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51 C.4.16 2D Data Matrix. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51 C-2
Psion Teklogix 7535 G2 Hand-Held Computer User Manual
Page 275
Appendix C: Bar Code Settings
C.4.17 2D QR Code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51 C.4.18 2D Maxicode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52 C.4.19 2D Aztec . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52 C.4.20 Postal: PlaNET . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52 C.4.21 Postal: PostNET . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53 C.4.22 Postal: Australian . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53 C.4.23 Postal: Japanese . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53 C.4.24 Postal: Korean . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54 C.4.25 Postal: Royal. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54 C.4.26 Postal: Kix . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54 C.4.27 Postal: Canadian . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54 C.5 Non-Decoded Scanners . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55 C.5.1 Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56 C.5.2 Code 39 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56 C.5.3 Code 128 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58 C.5.4 EAN 13 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59 C.5.5 EAN 8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60 C.5.6 UPC A. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60 C.5.7 UPC E . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61 C.5.8 Codabar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62 C.5.9 Code 93 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62 C.5.10 Code 11 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63 C.5.11 Interleaved 2 of 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64 C.5.12 MSI Plessey . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64 C.5.13 Discrete 2 of 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65 C.5.14 IATA 2 of 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
Psion Teklogix 7535 G2 Hand-Held Computer User Manual
C-3
Page 276
Page 277
Appendix C: Bar Code Settings Bar Code Settings Scanner Options
C.1
Bar Code Settings The Teklogix Scanners icon in the Control Panel provides dialog boxes in which you can tailor bar code options and choose the bar codes your scanner will recognize. The parameters are preset with the default settings of the decoded scanner installed in the unit. For a listing of available scanners and their specifications, please refer to Chapter 7: “Specifications”. Figure C.1 Teklogix Scanners Icon
C.1.1
Scanner Options The drop-down menu to the right of the Scanner option allows you to choose configurations for one of the following scanner types, depending on what is installed in/on your hand-held: Decoded (internal), Decoded (Intermec ISCP), Imager, and Non-decoded.
Psion Teklogix 7535 G2 Hand-Held Computer User Manual
C-5
Page 278
Appendix C: Bar Code Settings Bar Code Settings Restoring Default Settings
The symbologies listed change to reflect the scanner you choose and the bar codes it supports. Always defer to your bar code scanner’s programming manual when in doubt about the availability or settings for any parameter. Note: Your 7535 G2 comes preconfigured from the factory for internal scanner types. The type of scanner installed can be determined from the System icon in the Control Panel, under the System Properties tab. Important: To improve the decode speed and performance, enable (set to ‘on’) only those codes that are required by the application. Keep in mind that some bar code types are only available when an internal imaging scanner is installed. All internal scanners can be configured using these dialog boxes. External, nondecoded scanners are also configured through the Scanner Properties dialog box. However, external decoded scanners must be configured by scanning special configuration bar codes. In these cases, the scanner manufacturer provides programming manuals for configuration purposes. • •
C.1.2
For the Symbol LS3408 decoded scanner, refer to the programming guide supplied with your scanner. For PowerScan® (PSC) decoded scanners, refer to the PowerScan Programming Guide
Restoring Default Settings If you want to restore the factory defaults after making changes, the defaults can be applied to a selected parameter, sub-tree of parameters, or all scanner parameters.
C-6
Psion Teklogix 7535 G2 Hand-Held Computer User Manual
Page 279
Appendix C: Bar Code Settings Bar Code Settings Restoring Default Settings
•
Press and hold the stylus on a symbology (e.g., Code 128) to display a pop up a menu.
•
Choose Default subtree to reset only the parameters in the symbology you selected, or choose Default all settings to reset all scanner parameters to default settings.
To reset a single parameter to its default setting: •
Press and hold the stylus on the parameter you want to reset.
•
Choose Default parameter to reset the parameter to the default setting.
Psion Teklogix 7535 G2 Hand-Held Computer User Manual
C-7
Page 280
Appendix C: Bar Code Settings Decoded (Internal) Scanners Options
C.2
Decoded (Internal) Scanners
•
C.2.1
Tap on the Scanner drop-down menu, and choose Decoded (internal).
Options Note: Some options are available only for specific scanners. Refer to the option names in this section for scanner model identification. Dot Time (msec) The value selected for Dot Time (msec) determines (in milliseconds) how long the targeting dot remains on before the scanner switches to a normal scan sweep. When you double-tap on this parameter, a dialog box is displayed in which you can enter a value of 0 msec, 200 msec or 400 msec. A value of 0 (zero) disables the target dot. Aim Duration This parameter determines the total time the aiming pattern appears before the scanner laser begins sweeping. When you double-tap on this parameter, a dialog box is displayed in which you can enter a value from 0 to 30 (0 to 3 sec.). A value of 0 (zero) disables the aiming-dot. Laser On Time The value assigned to this parameter determines how long the laser will remain on when the scan button or trigger is pressed. Double-tapping on this parameter displays a dialog box in which you can enter a value between 5 and 99, each number representing 0.1 seconds.
C-8
Psion Teklogix 7535 G2 Hand-Held Computer User Manual
Page 281
Appendix C: Bar Code Settings Decoded (Internal) Scanners Decoded (Internal) Advanced Options
C.2.2
Decoded (Internal) Advanced Options Continuous Scan Mode Setting this parameter to on keeps the laser on and continuously decoding as long as the scanner button is pressed and held down. Minimum Cancel Time The value assigned to this parameter determines the time delay before the scanner is turned off, once the scanner trigger or button is released. This gives the scanner a minimum amount of time to complete its current decode before the scan is cancelled when you quickly trigger on/off. Power Mode This parameter is a power-saving option. Tapping on it displays a screen listing two power mode options: Continuous Power and Low Power. In Continuous Power mode, the scanner is always on, waiting for a trigger pull or a serial communication. In Low Power mode, the scanner is in a standby state, drawing minimal power until a trigger pull or serial communication wakes it. Keep in mind that while this option is more suitable for battery powered applications, there will be a slight delay while the scanner powers up to scan a bar code. Low Power Timeout To extend laser life, you can select the time the scanner remains active following a successful decode. The scanner wakes from low power mode when a bar code is scanned - a successful decode restores normal blinking. This is only used if the unit’s Trigger Mode has been changed to Continuous On. If the unit is used in a fixed mount this parameter might be used, but not if the unit is used as a hand-held. When you double-tap on this parameter, a dialog box is displayed in which you can choose a value of 30 sec., 1 min., 2 min. or 3 min. Note: This parameter is only used if the Trigger Mode has been set to Continuous On and the 7535 G2 is mounted in a fixed position; otherwise, ‘Low Power Timeout’ is not used. Parameter Scanning Setting this parameter to on enables decoding of parameter bar codes. Psion Teklogix 7535 G2 Hand-Held Computer User Manual
C-9
Page 282
Appendix C: Bar Code Settings Decoded (Internal) Scanners Decoded (Internal) Advanced Options
Linear Security Level This parameter allows you to select the security level appropriate for your bar code quality. There are four levels of decode security for linear code types (e.g., Code 39, Interleaved 2 of 5). Higher security levels should be selected for decreasing levels of bar code quality. As security levels increase, the scanner’s decode speed decreases. Double-tapping on this parameter displays a dialog box in which you can enter a value from 1 to 4. Linear security level 1 specifies that the following code types must be successfully read twice before being decoded: Code Type
Codabar MSI Plessey D 5 of 5 I 2 of 5
Length
All 4 or less 8 or less 8 or less
Linear security level 2 specifies that all types of codes must be successfully read twice before being decoded. Linear security level 3 specifies that code types other than the following must be successfully read twice before being decoded. The following codes must be read three times: Code Type
MSI Plessey D 2 of 5 I 2 of 5
Length
4 or less 8 or less 8 or less
Linear security level 4 requires that all code types be successfully read three times before being decoded. Bi-Direction Redundancy Note: This parameter is only valid if a” Linear Security Level” is enabled. When this parameter is enabled, a bar code must be successfully scanned in both directions (forward and reverse) before being decoded.
C-10
Psion Teklogix 7535 G2 Hand-Held Computer User Manual