Page 313
Appendix C: Bar Code Settings Decoded (Intermec ISCP) PDF-417
Add/Remove Data Refer to “Add/Remove Data” on page C-15 for details.
C.3.21 PDF-417 Enabled Set this parameter to on to enable “2D PDF-417”. Length Restriction Refer to “Length Restriction” on page C-14 for details. Add/Remove Data Refer to “Add/Remove Data” on page C-15 for details.
C.3.22 Micro PDF-417 Enabled Set this parameter to on to enable “2D Micro PDF-417”. Code 128 Emulation When this parameter is enabled, the scanner transmits data from certain Micro PDF-417 symbols as if it was encoded in Code 128 symbols. If Code 128 Emulation is enabled, the following Micro PDF-417 symbols are transmitted with one of the following prefixes: ]C1 if the first codeword is 903-907, 912, 914, 915 ]C2 if the first codeword is 908 or 909 ]C0 if the first codeword is 910 or 911 If Code 128 Emulation is set to off, the Micro PDF-417 symbols are transmitted with one of the following prefixes: ]L3 if the first codeword is 903-907, 912, 914, 915 ]L4 if the first codeword is 908 or 909 ]L5 if the first codeword is 910 or 911 Length Restriction Refer to “Length Restriction” on page C-14 for details.
Psion Teklogix 7535 G2 Hand-Held Computer User Manual
C-41
Page 314
Appendix C: Bar Code Settings Imager Codablock
Add/Remove Data Refer to “Add/Remove Data” on page C-15 for details.
C.3.23 Codablock Enable Codablock A Set this parameter to on to enable “Codablock type A”. Enable Codablock F Set this parameter to on to enable “Codablock type F”. Length Restriction Refer to “Length Restriction” on page C-14 for details. Add/Remove Data Refer to “Add/Remove Data” on page C-15 for details.
C.4
Imager
•
C.4.1
Tap on the Scanner drop-down menu, and choose Imager.
Imager Options TekImager Enabled Setting this option to on enables the imager installed in your hand-held.
C-42
Psion Teklogix 7535 G2 Hand-Held Computer User Manual
Page 315
Appendix C: Bar Code Settings Imager Imager Options
Continuous Scan Mode Setting this parameter to on keeps image capture active and continuously decoding as long as the scanner button is pressed and held down. Center Barcode Only Note: This parameter must be disabled when reading Composite bar codes. When more than one bar code is visible in a single snap shot, this parameter allows you to specify that only the centre image within the imager framing marker be read. When this parameter is set to on, the target dot is pointed at the centre image and only that image is returned. Max Number Barcodes Specifies the maximum number of bar codes the imager attempts to decode in an image. A maximum of 6 bar codes can be decoded at one time. Barcodes Must Decode This parameter specifies the minimum number of bar codes that the imager must decode in order to report success. Note: This number must be less than the number of bar codes assigned to Max Number Barcodes. The driver validates and reassigns the value if necessary. Window Width “Window Width” determines the width of the captured image in pixels. Note: The driver will validate and reassign the value assigned to this parameter, if necessary; the driver will also use the Window Width value to horizontally center the image in the field of view. Window Height This parameter determines the height of the captured image in pixels. Note: The driver will validate and reassign the value assigned to this parameter, if necessary; the driver will also use Window Height value to vertically center the image in the field of view.
Psion Teklogix 7535 G2 Hand-Held Computer User Manual
C-43
Page 316
Appendix C: Bar Code Settings Imager Imager Advanced Options
Dot Time (msec) The value selected for “Dot Time (msec)” determines (in milliseconds) how long the targeting dot remains on before the scanner begins capturing images. When you double-tap on this parameter, a dialog box is displayed in which you can enter a value of between 0 and 3000. A value of 0 disables the target dot.
C.4.2
Imager Advanced Options Important: Do not adjust the advanced options without first consulting Psion Teklogix technical support. Factory Defaults On Reboot The value assigned to this parameter determines whether or not the driver will restore the factory defaults to the imager device on the next reboot. Note: The driver will default the imager device on a ‘clean’ reset, regardless of the value of this parameter. Min Scan Duration This parameter defines the minimum amount of time in seconds that the imager will scan when the trigger is pressed and held down without successful decode. Note: The actual scan duration when the trigger is pressed relies on the value assigned to “Captures Per HW Trigger”, below. Captures Per HW Trigger The value assigned to this parameter determines the number of captures the imager device will take while the imager's internal hardware trigger is held down. Note: This parameter, together with “Min Scan Duration”, determines the actual scan duration. When the scan trigger is pressed and held down, the driver starts a timer based on the value of “Min Scan Duration” and also sends a command to emulate the hardware trigger. When completed, if the time has not yet expired, it will send another command to the imager device, forcing the imager to flash again using the value assigned to “Captures Per HW Trigger”.
C-44
Psion Teklogix 7535 G2 Hand-Held Computer User Manual
Page 317
Appendix C: Bar Code Settings Imager Imager Advanced Options
Auto Exposure Important: This parameter value should only be changed by qualified Psion Teklogix personnel. It should be left at the default value: on. Setting this parameter to on allows the imager to make automatic gain, integration and illumination adjustments based on ambient light before capturing the bar code. If the adjustment is insufficient, further adjustments are made automatically before another image is captured. Fast Converge Note: “Auto Exposure” must be set to on in order for this parameter to function. Keep in mind that while this parameter can improve imager performance, “Fast Converge” increases battery power consumption. Setting this parameter to on speeds the “Auto Exposure” process. It allows the imager to rapidly snap a number of bar code capture attempts while finding ideal values for gain, integration and illumination. Max Gain, Max Integration And Max Illumination Important: These parameter values should only be changed by qualified Psion Teklogix personnel. These parameters represent internal values used by the 2D imager. The “Auto Exposure” parameter automatically adjusts the Max Gain, Max Integration and Max Illumination parameters to produce the best bar code read. Keep in mind that “Auto Exposure” must be set to on in order for these parameter values to be automatically adjusted. Double-tapping on any of these parameters displays an associated dialog box in which an allowable range is displayed: Max Gain – 357 to 7920, Max Integration – 0 to 65535, Max Illumination – 0 to 7. Decoder Timeout The decoder is a set of algorithms that examine the image and attempt to find the bar codes, and then turn the pixels into data that the computer can use - this process takes time. “Decoder Timeout” limits the amount of time the decoder will spend attempting to decode an image, and forces it to stop and grab a new image, which will probably be easier to decode.
Psion Teklogix 7535 G2 Hand-Held Computer User Manual
C-45
Page 318
Appendix C: Bar Code Settings Imager Code 39
Note: When decoding multiple bar codes in one image, the value assigned to ‘Decoder Timeout’ should be increased to 200ms/extra bar code after the first. Adaptive Windowing “Adaptive Windowing” is an advanced technique used to speed up bar code recognition in certain applications. This parameter automatically reduces the size of the window to the user-programmed window size when it successfully decodes (which reduces decode time the next time it is used), but increases it to the full size window on a failed decode. Note: This feature assumes that you have reached an understanding about how the device operates in your application, and that, after a learning period, operators will get used to using the imager in one particular way. It also assumes that a trained operator will usually only have near miss scenarios. Constant Illumination “Constant Illumination” is used to reduce the intrusiveness of the device’s illumination on the observer. Instead of the illumination turning on and off every time the device attempts a decode (2-4 times per second), the illumination stays on from the time the trigger is pulled until a decode is successful. This feature is useful in low light environments, since it will also reduce the distraction that the illumination can have on nearby co-workers.
C.4.3
Code 39 Enabled Set this parameter to on to enable “Code 39”. Full ASCII If this parameter is enabled, the characters +, %, and / are used as escape characters. The combination of an escape character and the next character is converted to an equivalent ASCII character. Check Digit Verification When this parameter is enabled, the integrity of a “Code 39” symbol is checked to ensure that it complies with specified algorithms. Note: Only those “Code 39” symbols that include a MOD 43 check digit are decoded when this parameter is enabled.
C-46
Psion Teklogix 7535 G2 Hand-Held Computer User Manual
Page 319
Appendix C: Bar Code Settings Imager Code 128
Include Check If this parameter is enabled, the check digit is included with the decoded bar code data. Length Restriction Refer to “Length Restriction” on page C-14 for details. Add/Remove Data Refer to “Add/Remove Data” on page C-15 for details.
C.4.4
Code 128 Enabled Set this parameter to on to enable “Code 128. Length Restriction Refer to “Length Restriction” on page C-14 for details. Add/Remove Data Refer to “Add/Remove Data” on page C-15 for details.
C.4.5
EAN 13 Enabled Set this parameter to on to enable “EAN 13”. Addendum An addendum is a separate bar code, supplementary to the main bar code. This parameter provides three options: Disabled, Optional and Required. Depending on the value chosen for this parameter, an addendum is recognized or ignored. • Double-tap on Addendum to display a dialog box listing your options. • Highlight an item, and tap on OK. When “Addendum” is set to Disabled, the scanner does not recognize an addendum. If this parameter is set to Optional, the scanner searches for an addendum and if one exists, appends it to the main bar code. When the parameter is set to Required, the scanner does not accept the main bar code without an addendum. Note: Setting “Addendum” to ‘Optional’ reduces performance. It should only be chosen if at least some of the bar codes being read have addendums. Psion Teklogix 7535 G2 Hand-Held Computer User Manual
C-47
Page 320
Appendix C: Bar Code Settings Imager EAN 8
Add/Remove Data Refer to “Add/Remove Data” on page C-15 for details.
C.4.6
EAN 8 Enabled Set this parameter to on to enable “EAN 8”. Addendum Refer to “Addendum” on page 47. Add/Remove Data Refer to “Add/Remove Data” on page C-15 for details.
C.4.7
UPC A Enabled Set this parameter to on to enable “UPC A”. Addendum Refer to “Addendum” on page 47. Add/Remove Data Refer to “Add/Remove Data” on page C-15 for details.
C.4.8
UPC E Enabled Set this parameter to on to enable “UPC E”. Addendum Refer to “Addendum” on page 47. Add/Remove Data Refer to “Add/Remove Data” on page C-15 for details.
C-48
Psion Teklogix 7535 G2 Hand-Held Computer User Manual
Page 321
Appendix C: Bar Code Settings Imager Code 93
C.4.9
Code 93 Enabled Set this parameter to on to enable “Code 93”. Length Restriction Refer to “Length Restriction” on page C-14 for details. Add/Remove Data Refer to “Add/Remove Data” on page C-15 for details.
C.4.10 Codabar Enabled Set this parameter to on to enable “Codabar”. Length Restriction Refer to “Length Restriction” on page C-14 for details. Add/Remove Data Refer to “Add/Remove Data” on page C-15 for details.
C.4.11
Interleaved 2 of 5 Enabled Set this parameter to on to enable “Interleaved 2 of 5”. Check Digit Verification When enabled, this parameter checks the integrity of an I 2 of 5 symbol to ensure it complies with a specified algorithm – either USS (Uniform Symbology Specification) or OPCC (Optical Product Code Council). Include Check If this parameter is enabled, the check digit is transmitted along with the I 2 of 5 symbol. Length Restriction Refer to “Length Restriction” on page C-14 for details.
Psion Teklogix 7535 G2 Hand-Held Computer User Manual
C-49
Page 322
Appendix C: Bar Code Settings Imager RSS Code (Reduced Space Symbology)
Add/Remove Data Refer to “Add/Remove Data” on page C-15 for details.
C.4.12
RSS Code (Reduced Space Symbology) Enable Setting this parameter to on enables “RSS Code” scanning capability. Length Restriction Refer to “Length Restriction” on page C-14 for details. Add/Remove Data Refer to “Add/Remove Data” on page C-15 for details.
C.4.13 Composite A composite symbol includes multi-row 2D components making it compatible with linear and area CCD scanners along with linear and rastering laser scanners. Enabled Set this parameter to on to enable “Composite” bar code scanner. Important: To successfully read this type of bar code, the two types of symbologies included in the composite must be enabled. In addition, “Center Barcode Only” must be disabled (see page C-43).
C.4.14
PDF-417 Enabled Setting this parameter to on enables PDF-417 two dimensional (2D) coding. Length Restriction Refer to “Length Restriction” on page C-14 for details. Add/Remove Data Refer to “Add/Remove Data” on page C-15 for details.
C-50
Psion Teklogix 7535 G2 Hand-Held Computer User Manual