Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 4 of 5

RF Modem 3010 Product Reference Guide, pages 28 to 36

Pages 28 to 36 of 45

The original document is the PDF (534 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Symbol RFM-3010

Page 28

RF Modem 3010 Product Reference Guide

The RFM 3010 Keyboard Com 1

Radio

Status

Com 2

A

Prog.

Aux.

Power

B

Figure 3-3. RF Modem Keyboard

LEDs The LEDs are always enabled when the RFM 3010 is plugged into the wall charger. If the terminal is not connected to the wall charger, the LEDs, with the exception of POWER, are disabled unless the <STATUS> button is pressed. When <STATUS> is pressed, the LEDs are enabled for a default period of 20 seconds. This default time can be changed with modifications to the software. For additional information, refer to Appendix A: RFM 3010 BIOS API or the Series 3000 System Software Manual. The COM1, RADIO, and COM2 LEDs are called status LEDs. Their sole function is to report the status of communications to and from the RFM 3010. Table 3-1 lists the functions associated with these LEDs. Table 3-1. Status LED Communication Codes LED Color Green (blinking) Red (blinking) Red/Green/Orange (solid)

3-10

Meaning RFM 3010 receiving data. RFM 3010 transmitting data. Hardware problem.

Page 29

Operating the RFM 3010

The PROG LED is used to indicate status during Program Download. Table 3-2 lists what the LED colors mean during Program Download. Table 3-2. Program Download Communications Status Codes LED Color

Meaning

Green (blinking)

Terminal is ready for download.

Red (blinking)

Program in NVM needs to be erased.

Orange (blinking)

Program in NVM is being erased.

Green (solid)

The download was successful.

Red (solid)

An error has occurred during download.

You can program the AUX LED through the application. For additional information, refer to Appendix A, RFM 3010 BIOS API. The POWER LED shows whether or not the RFM 3010 is powered on and indicates low battery power. Table 3-3 lists what the POWER LED colors mean. Table 3-3. Power Button Communications Status Codes LED Color

Meaning

Green (solid)

Wall charger is plugged in; power is on and terminal is plugged into wall charger.

Green (blinking)

Terminal is warm or cold booting; power is on and terminal is running on battery power; terminal is not plugged into wall charger during Program Download.

Red (blinking)

Battery power is low.

Red (solid)

Battery power is low and terminal is plugged into wall charger.

3-11

Page 30

RF Modem 3010 Product Reference Guide

Keys Use the <A> key with <POWER> to boot the terminal to Program Download mode. You can program this key through the application. For additional information on programming this key, refer to the Series 3000 ADK. Use the <B> key with <STATUS> and <POWER> during cold boot sequences. You can program this key through the application. For additional information on programming this key, refer to the Series 3000 ADK. The <STATUS> key displays the status of COM1, RADIO, and COM2 if the RFM 3010 is not plugged into the wall charger. It is also used during boot sequences.

3-12

Page 31

Appendix A: RFM 3010 BIOS API Serial Chip ID Number Int AEh Function 7(AH) Description:

Establishes serial chip ID number.

Input:

AH = 7h ES:DI = 6-byte buffer location

Output:

ES:DI = 48-bit serial number MSB of 48-bit serial number at lowest address

A-1

Page 32

RF Modem 3010 Product Reference Guide

Enhanced LED Services For RFM 3010 Int B6h Function 3(AH) Description:

Turns the decode LED on/off.

Input:

AH = 3h AL = Sub-service code: 0 = OFF - turns off the LED specified in DL 1 = ON - turns on the LED specified in DL 2 = Set timeout - in CL for the LED specified in DL 3 = Reserved 4 = Toggle LED - toggles the LED specified in DL on and off CL = Timeout in seconds (used only for set timeouts) DL = LED selection: 0 = AUX 1 = PROG 2 = STATUS CH = Color: 00 = orange 10 = red 01 = green Note: The default timeout of the STATUS key is set to 20 seconds. Note: The default timeout of the AUX and PROG LEDs is set to 0 seconds.

A-2

Page 33

Appendix A: RFM 3010 BIOS API

BIOS Version Int AFh Function None Description:

Provides the BIOS version used by the RFM 3010.

Input:

None

Output:

AH = Gate array revision AL = Determines terminal class Note: For the RFM 3010, AL = 4. Note: Output values for the following registers are the same as for Series 3000 terminals (refer to the Series 3000 System Software Manual). DS:SI = Serial number (Reserved) DX = Length of serial number (Reserved) ES:DI = Copyright message, null terminated ES:BX = Version string address, null terminated CS = Length of version string

A-3

Page 34

RF Modem 3010 Product Reference Guide

Boot Sequence RFM 3010 boot sequences are listed in Table A-1. Table A-1. Boot Sequences Boot Procedure

Key Sequence

Warm Boot

<STATUS> <POWER>

Cold Boot

<STATUS> <B> <POWER>

Program Download

<A> <POWER>

ASCII and Scan Codes Assigned ASCII and scan codes assigned for the RFM 3010 are listed in Table A-2. Table A-2. ASCII and Scan Codes Assigned

A-4

Key

ASCII

Scan Code

<A>

49 (decimal)/ 31 (hex)

2 (decimal)

<STATUS>

50 (decimal)/ 32 (hex)

3 (decimal)

<B>

51 (decimal)/ 33 (hex)

4 (decimal)

Page 35

Appendix B: Error Recovery and Troubleshooting Error Messages Because the RFM 3010 does not have a video display, the LEDs change color to indicate problems. There is no specific LED color that indicates a problem for all RFM 3010 functions. Note:

The LEDs indicate status activity only if the RFM 3010 is plugged into a wall charger or if you press the <STATUS> button.

B-1

Page 36

RF Modem 3010 Product Reference Guide

Troubleshooting Table B-1. Troubleshooting Chart

B-2

Symptom

Possible Cause

Suggested Action

No POWER indicator

Battery pack is dead or missing, or terminal is not plugged into the wall charger.

Replace or recharge battery pack.

RFM 3010 does not respond when keys are pressed

- Application Program was not downloaded successfully. - No application present. - Application is not responding.

- Repeat downloading. - Reboot. - Cold boot.

Scanner does not operate

Scanner connection is loose or disconnected.

Reconnect scanner cable.

Scanner is broken.

Replace scanner.

Scanning head needs cleaning.

Clean scanner head.

- Bar codes do not meet industry standards. - No scanner enabling software.

Try scanning a different bar code.

Time and date are incorrect

Real-time clock needs to be reset.

Refer to the Series 3000 Application Programmer’s Reference Manual for additional information.

POWER LED is solid red

The battery is low.

Press <POWER> to return to power save mode, plug in the AC Adapter Cable, and charge as described in the section Charging the Battery in Chapter 2.