For the Symbol RFM-3010

Page 19

Chapter 3

Operating the RFM 3010 Initializing the RFM 3010 The RFM 3010 must be initialized before use. During the initialization process, an application program is downloaded from the host computer to the RFM 3010 via a modem cable, which has a male DB-25 connector at one end and a female DE-9 connector at the other end. The application program is then stored in the terminal’s nonvolatile memory (NVM, also called application EEPROM). This procedure uses the SENDHEX command on the PC and the Program Loader function on the terminal. For details on the SENDHEX command, refer to the Series 3000 Application Programmer’s Reference Manual. Other software may be used in place of SENDHEX.

Communication Parameters The communication parameters on the host and the RFM 3010 must match. The following parameters are fixed on the RFM 3010: •

19200 bps

•

7 bit data

•

Odd parity

•

Xon/Xoff flow control

• 1 stop bit Do not use a version of SENDHEX earlier than 3.0. Versions of SENDHEX earlier than 3.0 do not support flow control.

3-1

Page 20

RF Modem 3010 Product Reference Guide

Powering the RFM 3010 On and Off To increase the amount of time that the RFM 3010 can be used before its batteries must be recharged or replaced, turn it off when not in use. When powered off, the RFM 3010 saves power by not performing any processing functions. Powering the RFM 3010 on does not reset the system or its program; the program resumes in the same place as it was when it was powered off. The data stored in memory also remains intact. Before the RFM 3010 powers up, it checks the batteries for enough power to ensure reliable operation and data storage.

Normal Power To turn the RFM 3010 on or off, press <POWER>.

Automatic Power A number of other events may turn the RFM 3010 on or off, depending on the application program. •

The system may power on when a key other than <POWER> is pressed. This feature can be set by modifying the software. For additional information, refer to the Series 3000 System Software Manual.

•

The system may power on when the scanner trigger is pressed.

•

The program may power on the system at a preset time to perform unattended operations such as an overnight communications session.

•

The program may power on the system in response to a modem ring or an RS232 device connecting to the DB-25 connector.

• The system may power off automatically if it is not used for a period of time. This feature can be set by modifying the software. For additional information, refer to the Series 3000 System Software Manual.

3-2

Page 21

Operating the RFM 3010

Forcing Power Off If pressing <POWER> does not power off the terminal, the system can be forced to power off in order to reduce the drain on the batteries. To force the system to power off, press and hold <POWER> for 20 seconds until the terminal powers off. Do not attempt to power on the terminal and continue use. Return the terminal to your System Administrator to recover any data and correct the problem.

3-3

Page 22

RF Modem 3010 Product Reference Guide

Booting the RFM 3010 Powering on the RFM 3010 does not boot the system and does not initialize either the program or data. When it is necessary to initialize the RFM 3010, perform either a warm boot or a cold boot.

Warm Boot A warm boot resets the operating system while preserving the program and data on the RAM disk. This process is similar to pressing the <Ctrl+Alt+Del> keys on a PC, except that it does not clear the RAM disk. To perform a warm boot: 1. Power off the system. 2. Press <STATUS> and <POWER> simultaneously. Following a warm boot, the POWER LED is solid green if the terminal is plugged into the wall charger. If the terminal is operating on battery power, the POWER LED blinks green.

Cold Boot A cold boot fully resets the system and clears memory, including clearing the RAM disk. Any programs and data stored in memory or on RAM Disk are deleted. The NVM is not affected. CAUTION

This procedure erases all data and programs residing in dynamic memory and RAM Disk. All contents of the RAM disk are lost. To perform a cold boot: 1. Power off the system. 2. Press <STATUS>, <B>, and <POWER> simultaneously. Following a cold boot, the POWER LED is solid green if the terminal is plugged into the wall charger. If the terminal is operating on battery power, the POWER LED blinks green. 3-4

Page 23

Operating the RFM 3010

Booting to Program Download Mode Program Download mode transfers an application program from the host system to the RFM 3010. To prepare for Program Download mode: 1. Power off the host PC and the RFM 3010. 2. Verify that the RFM 3010 is plugged into the wall charger. The system cannot go into Program Download mode and the application cannot load unless the RFM 3010 is plugged into the wall charger. 3. Attach the DB-25 (male) connector to the RFM 3010’s COM1 port and the DE9 (female) connector to the host’s serial port.

Figure 3-1. Communication and Charger Connections 4. Power on the PC.

3-5

Page 24

RF Modem 3010 Product Reference Guide

Loading the Program 1. On the RFM 3010, press and hold <A>. Press and release <POWER>, then release <A>. If the terminal is not plugged into the wall charger, the POWER LED blinks green. The terminal must be connected to the wall charger within 30 seconds or the PROG LED changes to solid red. If the PROG LED is solid red, power the terminal off, plug the terminal into the wall charger, and repeat step 1. The terminal goes through a boot process and beeps twice. If the PROG LED blinks green, the terminal is ready for the download. Proceed to step 3. If the PROG LED blinks red, a program is currently stored in NVM. Continue with step 2. 2. Press <A> again to erase the existing NVM program. The PROG LED blinks orange while the program is being erased. When the program has been completely erased, the RFM 3010 beeps and the PROG LED blinks green. The terminal is now ready for the download. 3. Start the communications program on the PC. If you use the SENDHEX command with the modem cable connected to COM2, enter: sendhex pgmname 19200 com2 PGNAME is the name of the hex file being downloaded to the terminal and COM2 is the port that the modem cable is connected to on the PC. It is not necessary to include the .hex extension on the program name. 4. Once the SENDHEX program has been started, press <ENTER> on the PC to begin communications. 5. On the RFM 3010, wait for the PROG LED to show solid green. This confirms a successful download. If the PROG LED is solid red, an error has occurred. 6. To exit Program Download mode, reboot the terminal.

3-6

Page 25

Operating the RFM 3010

Ending Communications Turn the terminal off and detach the communications cable. To start the software running, reboot the terminal using the cold boot sequence.

Cancelling Communication At any time during the communication session, you may cancel communications by pressing <POWER> on the RFM 3010.

3-7

Page 26

RF Modem 3010 Product Reference Guide

Scanning The RFM 3010-0500 model supports the use of barcode scanning devices. The application program must implement routines for barcode scanning before scanning can actually be performed. Scanners supported by the RFM 3010 include all contact wand and laser scanners, with the exception of the LS 7000 (refer to Table 12 for a list of compatible scanners available from Symbol). For scanner troubleshooting tips, refer to Appendix B, Error Recovery and Troubleshooting.

Attaching a Scanner To attach a wand or laser scanner to a RFM 3010: 1. Power the system off. 2. Remove the rubber end cap seal from the end of the RFM 3010 where the antenna is, and plug the DE-9 connector in the scanner port.

Figure 3-2. Connecting a Laser Scanner If you are only using the scanner (DE-9) port, you may cut the rubber end cap seal along the seam in the middle, and discard the section of the cover which covers the DE-9 port. Similarly, if you are only using the RJ-41 port you may cut the rubber end cap seal along the seam in the middle and discard the section of the cover which covers the RJ-41 port.

3-8

Page 27

Operating the RFM 3010

Using a Laser Scanner Only detachable laser scanners, such as the LS 2000, may be used with the RFM 3010-0500. To use a laser scanner: 1. Power on the system and the scanner by pressing <POWER> or pulling the scanner trigger. 2. Point the scanner at the bar code, pull the trigger and adjust the aim so that the thin, red laser beam covers the entire length of the bar code. For the optimal scanning distance of a scanner, consult the scanner operator's manual.

Using a Contact Wand Scanner To use a contact wand scanner: 1. Power the terminal on. 2. Lightly touch the bar code with the tip of the wand, holding it at a 90- to 45degree angle above or below the line of the bar code. 3. Draw the wand smoothly and at a moderate speed from right to left or from left to right across the entire bar code. Depending on the program, a tone indicates a successful scan.