The text of a manual · part 5 of 5
RF Modem 3010 Product Reference Guide, pages 37 to 45
Pages 37 to 45 of 45
The original document is the PDF (534 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Symbol RFM-3010
Page 37
Error Recovery and Troubleshooting
Startup Failures If a cold boot does not successfully start the application, either the application, the system software, or the system is malfunctioning. If you can boot the system to Program Download mode, use the Program Loader function to download a new version of the application software to NVM (refer to Chapter 3).
Scanning Problems Bar code labels that do not meet established industry specifications may not scan successfully. These labels may include: • Smudged labels • Very dark or very light labels • Labels with highly reflective surfaces or coatings • Labels with poor color contrast
The following also may cause unsuccessful scans: • Moving the wand too quickly • Moving the wand too slowly • Moving the wand at an uneven speed • Moving the wand diagonally across the bar code
B-3
Page 38
Appendix C: Port Pin-Outs This Appendix provides reference information for RFM 3010 ports and mappings.
Scanner Port (DE-9) The scanner port is located at the top of the RFM 3010, next to the COM2 (RJ-41) port. This port is only available on the RFM 3010-0500 model. Table C-1. RFM 3010 Scanner Port Pin Descriptions Pin
Name
Function
Direction
1
LASERDIR
Laser direction indicator* input
2
BWD
Black/white data input
3
WANDLED
Wand LED control output
4 no connection
5
LASERTRIGN
Laser trigger NOT input
6
WANDELC
Wand electronics enable output
7
GROUND
Logic/power ground
8
GROUND
Logic/power ground
9
WANDPWR
Wand power (+5V)
output
* Must be grounded on contact wand scanners
C-1
Page 39
RF Modem 3010 Product Reference Guide
COM1 Serial Port (DB-25) The COM1 serial port is located at the bottom of the RFM 3010. Table C-2. RFM 3010 COM1 Serial Port Pin Descriptions Pin
Name
Signal
Direction
1
Not used
2
RECEIVED DATA
RXD
IN*
3
TRANSMIT DATA
TXD
OUT*
4
CLEAR TO SEND
CTS
IN*
5
REQUEST TO SEND
RTS
OUT*
6
DATA TERMINAL READY
DTR
OUT*
7
SIGNAL GROUND
GND, *
8
CARRIER DETECT
DCD
OUT
9
RS-422
TXD -
OUT
10
RS-422
TXD +
OUT
11-19
Not used
20
DATA SET READY
DSR
IN*
21
Not used
22
RING INDICATOR
RI
IN*
23
Not used
24
RS-422
RXD -
IN
25
RS-422
RXD +
IN
*RS-232 signal
C-2
Page 40
Port Pin-Outs
RF Modem 25-pin DB-25 Female 25 24 10 9
RXD + RXD TXD + TXD -
Other RS-422 Device (To be specified by the manufacturer.) RXD + RXD TXD + TXD -
Figure C-1. RFM 3010 COM1 RS-422 Cable
DE9 - Female DCD RXD TXD DTR GND DSR RTS CTS Ring
1 2 3 4 5 6 7 8 9
DB25 - Male 8 3 2 20 7 6 4 5
DCD TXD RXD DSR GND DTR CTS RTS
Figure C-2. RFM 3010 COM1 Modem Cable
C-3
Page 41
RF Modem 3010 Product Reference Guide
COM2 Null Modem Cable The COM2 null modem cable has a female DE-9 connector at one end and a male DB-25 connector at the other end.
Pin 1
Figure C-3. RFM 3010 COM2 Jack (Upside Down) DE9 - Female DCD RXD TXD DTR GND DSR RTS CTS Ring
1 2 3 4 5 6 7 8 9
RJ41 - Plug 2 5 3 9 8
DTR TXD RXD CTS/DSR GND
4
RTS
NC NC NC * 1 NC NC * 6 NC NC * 7 Ring NC * 10 KBPUP*
Figure C-4. RFM 3010 COM2 Null Modem Cable C-4
Page 42
Port Pin-Outs
COM2 Serial Port Connector (RJ-41) The COM2 serial port is located at the top of the RFM 3010, next to the optional DE-9 scanner port (refer to Figure 1-1). Table C-3. COM2 Serial Port Pin Descriptions Pin
Signal
Direction
1
Not used
2
+5 volts/DTR
OUT
3
RXD
IN
4
RTS
OUT
5
TXD
OUT
6
Not used
7
Ring Indicator RI
8
GND
9
CTS/DSR
10
Power-on
IN
C-5
Page 43
Index Numerics 15-Volt adapter . . . . . . . . . . . . . . . . . . 1-3
A A key . . . . . . . . . . . . . . . . . . . . . 3-12, A-4 AC adapter cable . . . . . . . . . . . . . . . . . 2-3 AC power adapter . . . . . . . . . . . . . . . . 1-1 AC power jack . . . . . . . . . . . . . . . . . . . 2-3 adapter charger . . . . . . . . . . . . . . . . . . 1-3 ADK. . . . . . . . . . . . . . . . . . . 3-2, 3-10, 3-12 ASCII and scan codes assigned . . . . . . . A-4 automatic power. . . . . . . . . . . . . . . . . . 3-2 auto-off power save mode . . . . . . . . . . 1-1 AUX LED . . . . . . . . . . . . . . . . . . . . . 3-11
B B key . . . . . . . . . . . . . . . . . . 3-4, 3-12, A-3 batteries chargers . . . . . . . . . . . . . . . . . . . . 1-3 charging . . . . . . . . . . . . . . . . . . . . 2-3 charging tips . . . . . . . . . . . . . . . . . 2-4 maintaining . . . . . . . . . . . . . . . . . . 2-1 replacing . . . . . . . . . . . . . . . . . . . . 2-2 battery charging tips . . . . . . . . . . . . . . 2-4 BIOS version . . . . . . . . . . . . . . . . . . . . A-3 booting the RFM 3010 . . . . . . . . . . . . . 3-4 booting to Program Download mode. . . 3-6
C cancelling communication . . . . . . . . . . 3-7 charging the battery . . . . . . . . . . . . . . . 2-3 cleaning the RFM 3010 . . . . . . . . . . . . . 2-1 cold boot . . . . . . . . . . 3-4, 3-7, 3-11, 3-12 function . . . . . . . . . . . . . . . . . . . . 3-4 performing . . . . . . . . . . . . . . . . . . 3-4 COM1 LED . . . . . . . . . . . . . . . . . . 3-10, 3-12 modem cable . . . . . . . . . . . . . . . . C-3 port (RS-232/RS-422) . . . . . . . . . . . 2-3 RS-422 cable . . . . . . . . . . . . . . . . . C-3 serial port pin descriptions . . . . . . . C-2 COM2 jack . . . . . . . . . . . . . . . . . . . . . . . . C-4 LED . . . . . . . . . . . . . . . . . . 3-10, 3-12 null modem cable . . . . . . . . . . . . . C-4 port (RJ-41) . . . . . . . . . . . . . . . . . . 3-8 serial port pin descriptions . . . . . . . C-5 communication parameters . . . . . . . . . 3-1
D DR DOS operating system . . . . . . . . . . 1-1
E EEPROM see NVM ending communications . . . . . . . . . . . . 3-7 error messages . . . . . . . . . . . . . . . . . . . B-1 scanning problems . . . . . . . . . . . . B-3 startup failures . . . . . . . . . . . . . . . . B-3
F forcing power off . . . . . . . . . . . . . . . . . 3-3
Index-1
Page 44
RF Modem 3010 Product Reference Guide
I initializing the RFM 3010 . . . . . . . . . . . 3-1
K keys . . . . . . . . . . . . . . . . . . . . . . . . . 3-12
L LED services . . . . . . . . . . . . . . . . . . . .A-2 LEDs . . . . . . . . . . . . . . . . . . . . . . . . . 3-10 communication codes . . . . . . . . . 3-10
M maintaining batteries . . . . . . . . . . . . . . 2-1
N NiCd . . . . . . . . . . . . . . . . . . . 1-1, 1-3, 2-3 product numbers . . . . . . . . . . . . . . 2-2 nickel cadmium see NiCd nonvolatile memory (NVM) see NVM normal power . . . . . . . . . . . . . . . . . . . 3-2 NVM . . . . . . . . . . . . . . . . . . . 3-1, 3-4, 3-6
O optional accessories . . . . . . . . . . . . . . . 1-3
P parts of the RFM 3010 . . . . . . . . . . . . . 1-2 Power key . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-2, 3-3, 3-4, 3-7, 3-9, 3-12, A-4 Power key communications status codes . . . . . . . . . . . . . . . . . . 3-11 POWER LED . . . . . . . . 3-4, 3-5, 3-10, 3-11 power plug. . . . . . . . . . . . . . . . . . . . . 2-3 powering the RFM 3010 on and off . . . . 3-2 automatic power . . . . . . . . . . . . . . 3-2
Index-2 forcing power off . . . . . . . . . . . . . 3-3 normal power . . . . . . . . . . . . . . . . 3-2 PROG LED . . . . . . . . . . . . . .3-6, 3-11, A-2 Program Download mode. . . . . . . . . . . . . . . . . . . . . . . . . . . 3-5, 3-6, 3-11, 3-12 booting to . . . . . . . . . . . . . . . . . . . 3-5 cancelling communication . . . . . . . 3-7 communications status codes . . . . 3-11 ending communications . . . . . . . . 3-7 preparing for . . . . . . . . . . . . . . . . 3-5 Program Loader . . . . . . . . . . . . . . . . . 3-1
R Radio Frequency Modem 3010 see RFM 3010 RADIO LED . . . . . . . . . . . . . . . 3-10, 3-12 replacing the battery pack . . . . . . . . . . 2-2 RF adapter . . . . . . . . . . . . . . . . . . . . . 1-6 RFM 3010 charging the battery see batteries defined . . . . . . . . . . . . . . . . . . . . . 1-1 keyboard . . . . . . . . . . . . . . . . . . . 3-10 models of . . . . . . . . . . . . . . . . . . . 1-1 operating conditions . . . . . . . . . . . 1-6 RFM 3010-0500 . . . . . . . . . . . .1-1, 3-8, C-1 RFM 3010-0T00 . . . . . . . . . . . . . . . . . . 1-1
S scanner port pin descriptions . . . . . . . . . . . C-1 problems . . . . . . . . . . . . . . . . . . . B-3 scanner port (DE-9) . . . . . . . . . . . . . . . 3-8 scanners . . . . . . . . . . . . . . . . . . . . . . . 1-3 contact wand . . . . . . . . . . . . . . . . 1-4 laser . . . . . . . . . . . . . . . . . . . . . . . 1-4 scanning . . . . . . . . . . . . . . . . . . . . . . . 3-8
Page 45
Index attaching a scanner . . . . . . . . . . . . .3-8 model of RFM 3010 . . . . . . . . 3-8, C-1 using a contact wand scanner . . . . .3-9 using a laser scanner . . . . . . . . . . .3-9 sendhex . . . . . . . . . . . . . . . . . . . . 3-1, 3-6 serial chip ID number . . . . . . . . . . . . . A-1 Series 3000 Application Developers Kit see ADK Series 3000 Application Programmer’s Reference Manual . . . . . . . . . . .1-1 startup failures . . . . . . . . . . . . . . . . . . B-3 Status key . . . . . . . 3-4, 3-10, 3-12, A-2, A-4 Status LEDs . . . . . . . . . . . . . . . . . . . . . 3-10 storing the RFM 3010 . . . . . . . . . . . . . .1-6 super capacitor . . . . . . . . . . . . . . . . . . .2-1
T troubleshooting . . . . . . . . . . . . . . . . . B-2
U UBC Adapter Cartridge . . . . . . . . . . . . .1-3 Universal Battery Charger (UBC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3, 2-3
W wall mounting bracket . . . . . . . . . . . . .1-3 instructions . . . . . . . . . . . . . . . . . .1-5 warm boot . . . . . . . . . . . . . . . . . 3-4, 3-11 function . . . . . . . . . . . . . . . . . . . . .3-4 performing . . . . . . . . . . . . . . . . . . .3-4
Index-3