Page 147
Configuring the Terminal
Copy Components to the Script Copy files or directories to the script being generated: 1. Click on the File Explorer Window to make it the active window. 2. Click on the source directory in the Directory Tree Pane. TCM displays the directory contents in the Contents Pane. 3. Click on the file(s) and/or directory in File Explorer. Note: Optionally, use the standard Windows Shift+Left-click and Control+Left-click features to select multiple files and directories. 4. Drag and drop the selected file(s) and/or directory from File Explorer to the target directory in the Script Window. OR Click on the target directory and select the File Explorer Copy icon from the toolbar.
Save the Script To save the changes to a new script: 1. From the File menu, choose Save As. OR On the toolbar, click on
.
2. Enter the path and filename. TCM appends a .TCM extension to the script. 3. Choose the OK button. Note: If you save an untitled script, TCM by default saves the script to the directory that the Script Browser is pointing to. To save changes to an existing script: •
From the File menu, choose Save, OR
•
On the toolbar, click
.
11-7
Page 148
PPT 2700 Series Product Reference Guide
Note: If you open and make changes to an existing script, saving the changes writes over the existing script. If you wish to use an original or Symbol-supplied standard script as a base and save the changes in a new script, use Save As instead of Save after making the changes.
Building the Image As part of the build, TCM performs a check on the script which verifies that all files referenced in the script exist. If the image is bootable, TCM verifies that the boot files are available. Note: Performing a check is more important for previously existing scripts to ensure that files referenced in the script are still in the designated locations. To check a script: 1. In the Script Window, select the script. 2. Save the script, if not already saved. 3. From the Script Menu, choose Check. OR On the toolbar, choose
.
4. TCM verifies that files referenced in the script exist on available drives and lists an error message in the Errors found box for any missing files. 5. Choose the OK button to exit. To build a script: 1. In the Script Window, select the script to be built. 2. From the Script menu, select Build. OR
11-8
Page 149
Configuring the Terminal
On the toolbar, choose
. The Configure Build window appears.
3. Select whether to build the partition table, or one volume. 4. Select ASCII format for your hex image, or Compression, which reduces the size of most hex images in order to speed downloading. Click OK. 5. TCM performs a check. If the script is has no errors, TCM proceeds with the build.
If the Build Fails If the build fails, TCM displays a message indicating which file(s) are missing. If the total amount of flash required by the script exceeds the image size, a TCM error results. To correct this, reduce the number of files in the volume, or make the disk nonbootable. Refer to Defining Script Properties on page 11-4 for more information on setting the image size appropriately.
11-9
Page 150
PPT 2700 Series Product Reference Guide
Sending the Hex Image Once the hex file is built, you are ready to download it to the terminal. A Hex image download requires both TCM and a program loader stored on the terminal. The terminal comes with a program loading utility, Initial Program Loader (IPL), stored in the terminal’s write-protected flash. To run IPL, the terminal must be inserted in a cradle or connected to a host PC by direct serial connection.
Saving the Script If you made changes to the script since last saving it, save the script again.
Connect The Terminal and Development PC To send the hex file to the terminal, first link the terminal and development PC by one of the following devices: •
Direct serial link
•
Cradle (refer to Chapter 1, Getting Started for more information on setting up the cradle).
Begin the Send in TCM In TCM on the PC: 1. Select the script. 2. From the file menu, choose Load Terminal. OR On the toolbar, choose
11-10
. The Load Terminal screen displays.
Page 151
Configuring the Terminal
3. If the correct hex file is not displayed in the Hex File to Load field, click on the browse button and navigate to the correct hex file to be downloaded. 4. Click on the Comm Port pull-down menu and select the COM port being used. Ports already in use display in the Unavailable Ports field. 5. Click on the Baud Rate pull-down menu and select the appropriate baud rate. Your options are 2400, 4800, 9600, 19200,38400, 57600, 115200. 6. On the Protocol pull-down menu, select None.
Setting Up IPL to Receive the File To set up IPL on the terminal to receive the files being downloaded via TCM: 1. Cold boot the terminal by pressing the reset button inside the battery compartment while holding down the Function button. 2. Press and hold the App1 and App4 buttons. While holding down these buttons, press and hold the battery door switch inside the battery compartment (on the left). This all must occur within 3 seconds after resetting the terminal.
11-11
Page 152
PPT 2700 Series Product Reference Guide
3. Continue to hold these buttons, including the battery door switch, until the IPL Baud Rate menu displays: IPL VER X.XX IPL Key Sequence -> 115,200 57,600 38,400 19,200 9600 Auto Baud Press Up/Down to select Baud Rate Action to Continue
If necessary, adjust the contrast by holding down the Function button and pressing the up scroll button to darken the screen, or the down scroll button to lighten the screen. 4. The version number on the top of the screen identifies the version of IPL you are using. After the version number one of the following messages appears, indicating why IPL was invoked: •
IPL Key Sequence: IPL key sequence was pressed.
•
Partition Table not found: indicates no partition table was found.
•
Partition Table Checksum Error: indicates a checksum error was detected in the partition table.
Use the up and down scroll buttons on the terminal to scroll to the appropriate baud rate, then press the Action button to accept the selected baud rate. If no selection is made within 10 seconds, the baud rate 115,200 is automatically selected.
11-12
Page 153
Configuring the Terminal
5. IPL displays the Main Menu which lists the partitions/applications that can be downloaded. IPL Ver X.XX IPL Key Sequence Windows CE Platform Application Data Splash Screen IPL Partition Table Auto Select Press Up/Down to select partition Press Action to begin download
6. Use the up and down scroll buttons to select the partition to be received, then press the Action button, or select Auto Select to download several partitions in sequence. Note: Auto Select is the default, and will be selected if no other selection is made within 10 seconds. 7. The following screen displays: IPL VER X.XX Partition Name Waiting for Data at Baud Rate XXX,XXX Press Action to return to Main Menu
Partition Name reflects the selection made on the Main Menu, and Baud Rate XXX,XXX displays the selection chosen from the baud rate menu. This screen continues to display until the first character of the image to be
11-13
Page 154
PPT 2700 Series Product Reference Guide downloaded is received from the host. While this screen is displayed, pressing the Action button returns IPL to the Main Menu screen. 8. Insert the terminal in a cradle, or connect it to a host PC with a serial cable. 9. Return to the host PC, and press the OK button on the Load Terminal dialog box. 10. As soon as the first character of data is received, IPL displays the receiving screen: IPL VER X.XX Partition Name Downloading Data Processing XXXXX KB of YYYYY KB image
Note: If the Pre-erase Attribute bit is set on the partition being downloaded, the message “Pre-Erasing Flash” also appears. This screen indicates that the area selected in the Main Menu screen is currently downloading, and displays until an entire image is received, or until an error is detected. As more data is received, the Receiving Screen is updated to reflect the current status. To process the data, IPL must receive, erase, and write the entire image. With the exception of the disk images, IPL receives the entire image before starting the erase, and completes the erase before starting to write. With disk images, IPL multiplexes all three operations as data is received. 11. When the entire image is received, IPL indicates that the download is complete. IPL VER X.XX Partition Name Download Complete Press Action to return to Main Menu Cold Boot Exits IPL
If Auto Select was selected on the Main Menu, the text “Auto Select Enabled” appears in place of “Cold Boot Exits IPL.”
11-14