Page 155

Configuring the Terminal

12. If Auto Select was selected on the Main Menu, IPL immediately returns to the Waiting for Data Screen to wait for the next image. If any other selection was made on the Main Menu, IPL stays at the success screen until you press Action. Once the screen is acknowledged, IPL returns to the Main Menu to wait for a new selection. 13. When all partitions are downloaded successfully, cold boot the terminal by pressing the reset button inside the battery compartment while holding down the Function button. 14. Close TCM on the host PC by selecting Exit from the File Menu.

11-15

Page 156

PPT 2700 Series Product Reference Guide

Error Messages IPL Error Detection While receiving data, IPL performs many checks on the data to ensure that the data is received correctly. If an error is detected, IPL immediately aborts the download, and reports the error on an error screen: IPL VER X.XX Download Failed! Error Condition Press Action to return to Main Menu

This screen displays until you press Action. Once the screen is acknowledged, IPL returns to the Main Menu screen to wait for a new selection. The cause of the error displays under the Download Failed! indication. The errors that can be reported, and the probable cause of the error, are as follows:

Invalid Image

This error occurs if another record is received before the Header Record. Ensure the Header Record is the first record downloaded.

Partition Not Defined

The destination code is part of the Header record and is used as an index into the partition table. The partition table entry located at this index contains partition information for the data downloaded. If the AutoSelect option is selected, a check is made to ensure that valid partition information exists in the partition table at this index. The check verifies that the Area Name and Sector Size are both nonzero. If not, this error occurs.

Wrong Partition

If a specific partition is selected from the partition list, and the destination code of the Header record downloaded does not match the index of that partition, this error occurs.

Image Too Big

The size of the image is also part of the Header record. If the data to be written exceeds the size of the partition as indicated in the partition table, this error occurs.

11-16

Page 157

Configuring the Terminal

Invalid Image

This error occurs if another record is received before the Header Record. Ensure the Header Record is the first record downloaded.

Incorrect Byte Count

Image data is processed until the End Of File (EOF - Record Type 01) record is received. This error occurs if IPL detects that the number of bytes received does not equal the number of bytes sent.

Unable to Verify Partition Data

If the Receive and Verify bit is set for that partition, the data is verified, the flash sector erased, and the data written to the flash part. If this data can not be verified, this error occurs.

Transmission Errors

The following error messages may appear if an error occurs during transmission: Checksum Error occurs if an invalid checksum is detected in the record. Invalid Record occurs if a record is not defined in the Symbol Hex File Format. Connection Lost occurs if one of the handshaking lines is deasserted during download. Address Out of Sequence occurs if the address of the data received is not sequential.

TCM Error Messages TCM validates the cells in your partition table when the Execute button is pressed. Cells highlighted in red contain an error. Partition loading is disabled until all errors are corrected. Following are errors that TCM may encounter, and possible solutions. Error - Partition Size

The size of a partition must be an integral multiple of the FFSSectorSizeInBytes specified by the .ini file. When the user enters a partition size, TCM rounds up to the next highest integral multiple of the sector size and displays this value in the partition table grid. This error check is made upon value entry, independent of the Execute button.

Error - Image Larger than If the required size of the binary image file is larger than the associated Partition partition size, the Partition Size cell in the partition grid turns red to highlight the error. The Required Size cell indicates the actual size required. Error - Total size of all FFS Partition

If the total memory allocated to the 3 FFS partitions is greater than the total Flash Memory on the terminal, the Used FFS Memory display box turns red. Decrease the size of one or more of the partitions, then recheck the configuration using the Execute button.

11-17

Page 158

PPT 2700 Series Product Reference Guide

Error - Partition Size

The size of a partition must be an integral multiple of the FFSSectorSizeInBytes specified by the .ini file. When the user enters a partition size, TCM rounds up to the next highest integral multiple of the sector size and displays this value in the partition table grid. This error check is made upon value entry, independent of the Execute button.

Error - Source/ Destination Path Verification

If the directory paths specified by the Source and Destination cells do not exist, the cell containing the non-existent path turns red to highlight the error.

11-18

Page 159

Configuring the Terminal

Creating a Splash Screen To generate a custom splash screen, use Microsoft Visual Studio, Microsoft Visual C++ version 6.0. Select Insert, Resource. Next, select Bitmap, New. To create the screen: 1. Create a 4-color bitmap with dimensions of BX x BY where: •

BX is less than or equal to 240 pixels

•

BY is less than or equal to 320 pixels

•

The bitmap is less than 240 by 320 pixels

•

4 colors must be selected

•

The total bitmap size must be less than or equal to 16384 (16K).

Generally, the bitmap file size should be less than or equal to 16384 bytes (16K). 2. To change the bitmap properties, double-click on the bottom-right corner of the bitmap when the cursor appears as a double arrow. The Bitmap Properties dialog box displays. 3. Select Width (<240), Height (<320) and Colors (4). 4. Select 4 colors so that 2 bits are used for each pixel of data in the bitmap file. 5. Select a new file name. 6. Select Image from the toolbar. Select Flip Vertical to invert the image. If other tools are used, be sure to create the bitmap with the size less than or equal to 16K and with 4 colors.

11-19

Page 160

PPT 2700 Series Product Reference Guide

Loading the Splash Screen via TCM To load the bitmap: 1. Click TCMMain.exe in the TCM directory. 2. Connect the PPT 2700 to the PC and invoke IPL to prepare the terminal to receive the splash screen download. 3. In the partition table, double-click on the Source column entry box for Splash Screen. The Specify Source dialog box appears. Select the bitmap file. 4. Double-click on the Destination column entry box for Splash Screen. 5. Select Create Image in the Hex Image file dialog box. 6. After the image is created, select Load. 7. Close TCM.

11-20