Page 139

Chapter 10 Software Installation on Development PC Introduction To develop applications to run on the PPT 2700, the Symbol Windows CE Software Developer’s Kit (SDK) is available. This SDK contains PPT 2700-specific software not available in the standard Microsoft Windows CE Platform SDK. The minimum system configuration required to install the SDK is: • IBM-compatible PC with Pentium 150 MHz processor or higher •

Windows®98 second edition, or Windows® NT operating system version 4.0 with Service Pack 5 or later, or Microsoft Windows 2000 operating system

•

24MB RAM for Windows 98, 32 MB RAM for Windows NT

•

100MB available hard disk space

•

CD-ROM drive

•

One available serial port

•

Mouse.

Also, be sure the drive you are installing to accepts long filenames (larger than the 8.3 filename convention).

Before You Install the SDK Before you install the Symbol Windows CE SDK, install the following tools: • Microsoft eMbedded Visual Tools 3.0. •

Windows CE Platform SDK for Pocket PC.

•

Microsoft ActiveSync. 10-1

Page 140

PPT 2700 Series Product Reference Guide

Symbol Windows CE SDK The SDK installation program loads the required Windows CE components on the development PC used to create the image files (via Terminal Configuration Manager) for download to the terminal. The Symbol SDK includes: •

Symbol-provided files

•

Printer drivers

•

TCM scripts

•

Sample code

•

This Product Reference Guide.

Installing the SDK on the Development PC The Symbol SDK installs through Windows in the directory C:\SYMBOL WINDOWS CE SDK, and also installs files in the Windows CE Tools directory (generated by the CE Tool Kit).

Installing the SDK Install the SDK from the Symbol website www.symbol.com. Follow the installation prompts. Note: To ensure the best operation of the SDK, do not change the base path set up in the installation. Once installation of the SDK is complete, use eMbedded Visual C++ or eMbedded Visual Basic to view the active Windows CE configuration, Microsoft Pocket PC, and display the directory in which the SDK is installed.

Installing Other Development Software Developing applications for the PPT 2700 may require installing other development software such as application development environments on the development PC. Follow the installation instructions provided with this software.

10-2

Page 141

Chapter 11 Configuring the Terminal Introduction This chapter describes the Terminal Configuration Manager (TCM), and how it is used to specify and load files into the flash memory of the PPT 2700 using the terminal’s Initial Program Loader (IPL). In TCM, you create a script that contains the information (commands to copy files) for building the image. TCM works with directory windows which display the directory structure of your script and the source directories, files, and scripts from which you pull components. You can open multiple scripts, drag and drop items from a drive/directory to the script, rename and delete files in the script, etc. Upon building the image, TCM adds all the files, directories, and scripts referenced in the script to the image. The SDK includes a number of standard scripts and demos/samples for you to use as a base for creating your own scripts. These scripts can be found in the SYMSDK\SCRIPTS directory. Note: Before you create a script to build a hex image, identify the files required (system files, drivers, applications, etc.) and locate the files’ source directories to make the script building process easier. The required processes for building a hex image in TCM include: •

Starting TCM

•

Creating or modifying a script

11-1

Page 142

PPT 2700 Series Product Reference Guide

•

Building the hex image

•

Sending the hex image.

Starting Terminal Configuration Manager To start TCM, double click on the TCM icon in the SYMSDK group. The following screen appears, displaying two directory windows; Script1 and File Explorer. Each directory window is split; the left half (or pane) of the window displays the directory tree for the current drive, and the right half displays the directory contents for the current drive.

11-2

Page 143

Configuring the Terminal

The following table lists the components of the TCM start-up screen. Table 11-1. TCM Screen Components Component

Description

Script Window

Associated with a script file containing the information to create a Flash Disk image. This window is the target window, or the primary TCM window in which you can create a script or change a script file’s contents by copying, deleting, and renaming files and directories. More than one script window can be open at a time. The Script Window consists of two panes, the Directory Tree Pane on the left and the Directory Contents Pane on the right. Subordinate directories and files of each volume are listed in the Directory Contents Pane.

File Explorer

A read-only source window for files and/or directories to include in the script being built.

Tool Bar

Contains the tools, illustrated below, for taking action on a script. Create a new script file.

Check script for existing files.

Open a script file.

Select the hex image to load.

Save a script file.

Tile windows.

View script properties.

Build and send the hex image to the terminal.

Build a script.

11-3

Page 144

PPT 2700 Series Product Reference Guide

Defining Script Properties Before a script is created, the script properties must be defined. This defines the type of terminal, type of flash type, number of disks being created, and the memory configuration of each disk volume. To define the script properties: 1. With TCM open, click on the Script Window to make it the active window. 2. Under the script menu, select the Properties option. OR Click on from the tool bar. The Script Properties window displays.

3. Under the Terminal pull-down menu, select 2700CE. 4. In the Flash Type field, select 0808A Flash Type. 5. Under the Disks pull-down menu, select the number of disk volumes to be created.

11-4

Page 145

Configuring the Terminal

Note: The options available under the disks pull-down menu changes depending on the flash type. Some flash types only have one option for the number of disk volumes, others have two options. 6. If you have selected three volumes under the disk pull-down menu, you have the option to change the memory configuration of the second and third volumes. To do so, click on the up or down arrow for either of the volumes, until the memory configuration of each is set to the desired value. You will notice that as you change the values for one of the volumes, the other volume is automatically changed accordingly. 7. For each disk volume, determine the Read/Write access option. 8. The Script File Path displays the path of the selected script file. 9. Select a Cushion percentage from the Cushion pull-down menu to specify the percent of flash reserved for cushion. Choosing a higher number reduces disk storage space, but also increases write performance on fragmented disks or disks becoming full. To speed the writing process, select as high a number as your storage needs permit (up to 25%).

11-5

Page 146

PPT 2700 Series Product Reference Guide

Creating the Script for the Hex Image On start-up, TCM displays the screen shown on page 11-2, with the Script1 window and File Explorer window pointing to the SYMSDK\SCRIPTS directory and the SDK7X00 directory. The Script1 Window directory pane displays three volumes: Volume1, Volume2, and Volume3. Depending on the type of flash chip you have, the number of volumes may change. Files can be added to each of the volumes. •

Create a new script file or open an existing script

•

Drag and drop existing files and directories to that script

•

Set the script parameters

•

Save the script

•

Review and modify the script.

Each process is described in the sections that follow.

Open a New or Existing Script Scripts are created in the Script Window. To open a new script: •

Choose New from the File Menu, OR

•

Click on from the tool bar.

To open an existing script (e.g., a standard script provided in the SDK): •

Choose Open from the File Menu and select the script file name, OR

•

Click on

•

Double click on an existing script in the Script Browser window.

from the toolbar and select the script file name, OR

Note: If you open and make changes to an existing script, saving the changes writes over the existing script. If you wish to use an original or Symbol-supplied standard script as a base and save the changes in a new script, use Save As instead of Save after making the changes.