The text of a manual · part 8 of 12

PDT 6100 Series Product Reference Guide: Chapter 6 Maintaining the Terminal

Pages 52 to 61 of 108, from PDT 6100 Series Product Reference Guide

The original document is the PDF (1.5 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Symbol PDT-6100, Symbol PDT-6110 and Symbol PDT-6146

Page 52

Chapter 6 Maintaining the Terminal Batteries The PDT 6100 terminal’s primary power is provided by a nickel metal hydride (NiMH) battery pack.

Battery Life Many factors affect battery pack life, including temperature, battery age, and data collection method. Uses and operating conditions which affect battery life are: !

scanning

!

“power save” mode

!

radio communications

!

backlighting

!

very high operating temperatures

!

very low operating temperatures.

The approximate battery life between charges is summarized in Table 6-1. Note that these values vary with the application. Applications involving radio communications shorten these times.

6-1

Page 53

PDT 6100 Product Reference Guide

Table 6-1. Battery Life: PDT 6100 Battery Type 1500 mAh NiMH

Input Method

Approx. Operating Approx. Operating Approx. Operating Time: PDT 6100 Time: PDT 6110 Time: PDT 614X

Keyboard

50 hours

45 hours

48 hours

Laser Scanner

6400 + scans

6100 + scans

6200 + scans

Radio

N/A

7.5 hours

10 hours

* Power consumption is highly application-dependent. The figures above represent battery life of typical applications. However, battery life with individual applications will vary.

When to Replace or Recharge Batteries The terminal provides two types of indicators to notify you when battery power is running low: warning messages and modified cursors. These indicators may be changed or disabled by an application program. !

LOW POWER, When the battery is low, the cursor changes as shown in Table 6-2 If ERR3000 is loaded, the message LOW BATTERY also appears. At this level, the terminal continues to operate, but there is probably less than 1 hour of usable power left.

!

VERY LOW, When the power is very low, the DEAD BATTERY message appears and the system powers off. Replace or recharge the battery before attempting to use the terminal. If the battery is not immediately recharged or replaced, data may be lost.

Battery life varies between 500 - 1000 charge / discharge cycles. This variation depends on the depth of discharge. In general, replace batteries which exhibit less than 80% of their total rated capacity.

6-2

Page 54

Maintaining the Terminal

Table 6-2. Cursor Indicators

33222010.eps

Supercap Power Backup To prevent data loss during battery replacement, the terminals have a supercap power backup. The supercap backup provides sufficient power to preserve memory contents for approximately 15 minutes while batteries are replaced. The supercap does not provide enough power to operate the terminal. On receiving a low battery message, replace or recharge the primary batteries immediately.

Replacement Batteries A rechargeable 1500 mAh NiMH battery pack, p/n 21-33061-01, can be ordered from Symbol Technologies.

6-3

Page 55

PDT 6100 Product Reference Guide

Installing a New or Recharged Battery Pack To install a new or recharged NiMH battery: 1. Turn the battery pack latch counterclockwise and remove the battery compartment door.

Figure 6-1. Removing the Battery Compartment Door 2. Lift the battery pack out. 3. Slide a NiMH battery pack in the compartment, with the contacts facing inside the compartment and the tab facing the top of the compartment (Figure 6-2). Tab

Contacts

Figure 6-2. Inserting the NiMH Battery Pack

6-4

Page 56

Maintaining the Terminal

4. Replace the battery compartment door (Figure 6-3).

Figure 6-3. Replacing the Battery Compartment Door 5. Turn the latch clockwise to secure the battery.

Charging the Battery Using the CRD 6100 To charge the NiMH battery in the PDT 6100: 1. Seat the PDT 6100 in a CRD 6100 connected to a power source.

Figure 6-4. Seating the PDT 6100 in the CRD 6100 2. The PDT 6100’s Charging LED flashes yellow at the start, lights solid yellow while the battery is charging, and lights solid green when the battery is fully charged. The charging time required is approximately 2.5 hours.

6-5

Page 57

PDT 6100 Product Reference Guide

Using the CCC The optional CCC provides power from a wall-mounted power supply for recharging the NiMH battery while the 6100 is in use. To connect the 6100 and the CCC: 1. Plug the CCC’s 10-pin RJ41 connector in the 6100’s base. 2. Plug the connector from the 12V power supply in the CCC’s power input jack (power supply p/n 50-14000-086). 3. Connect the power supply’s connector to a power line cord.

33222013.eps

Figure 6-5. Connecting the CCC 4. Connect the power line cord to a wall outlet. Batteries recharge in 2.5 hours.

6-6

Page 58

Maintaining the Terminal

Recharging a Spare Battery Pack To recharge a spare battery pack in the cradle: 1. Insert the battery pack sideways, contacts down, into the spare battery slot, with the tab facing either the right or left side of the cradle. 2. Angle one side of the battery under the lip on the cradle’s well. 3. Press down on the other side of the battery until the latch catches. Latch

Lip on cradle well

Battery Tab

Charging LED

Figure 6-6. Charging a Spare Battery Pack The cradle’s Charging LED flashes yellow when the battery is first inserted. The LED lights solid yellow to indicate the spare battery is charging, and switches to solid green when the battery is charged. The spare battery recharges in 2.5 hours. 4. Remove the spare battery and place it in the PDT 6100, or leave it in the cradle for temporary storage. To remove the battery, grip on either side of the battery and lift it out of the charging slot. Note: The spare battery can be inserted with the tab pointing to either side of the cradle well.

Other Charging Options The NiMH battery pack can be charged in the UBC 2000 Charger. See instructions provided with the charger for more information.

6-7

Page 59

PDT 6100 Product Reference Guide

Battery Charging Tips For maximum capacity and battery life: !

Charge at temperatures between 0 oC and 40oC (32oF and 104oF). Optimum oC to 25oC). Above or below that charging occurs at room temperature (about 20 range, batteries may not charge to rated capacity.

!

Recharge as soon as you see the "Low Battery" message.

!

Charge NiMH batteries after storage.

Cleaning The terminal requires a minimum amount of maintenance. However, keep the terminal clean to avoid problems and prolong the terminal’s life. Before doing any maintenance or cleaning, power the terminal off. To clean a terminal, use a clean, soft cloth dampened with a mild cleaner such as soap and water. Do not use abrasive paper, cloth, or abrasive/corrosive cleaners. Wipe the entire terminal, except for the scanner window, with the damp cloth. Clean the keypad and scanner triggers. Wipe the scanner window periodically with a lens tissue or other material suitable for cleaning optical material such as eyeglasses.

Caution Do not pour, spray, or spill any liquid onto any part of the terminal, particularly the scanner or scan element components.

Storage If the terminal will not be used for a while, store it in a cool, dry place, away from dust. For the best protection, repack the terminal in the original shipping container for storage.

Caution If you remove the primary battery, the terminal maintains memory contents for at least 15 minutes. To prevent loss of programs and data, transmit them

6-8

Page 60

Maintaining the Terminal to a host computer before removing the primary batteries for longer than 15 minutes. When you remove the terminal from storage without the battery pack, reset the real time clock. Refer to the Series 3000 Application Programmer’s Reference Manual or Series 3000 Application Programmer’s Guide for specific instructions.

6-9

Page 61

PDT 6100 Product Reference Guide

6-10