Chapter 7 Error Recovery and Troubleshooting Introduction This chapter provides information to assist in basic trouble analysis and correction for the PDT 6100, including: !

Error messages

!

Troubleshooting start-up failures

!

Troubleshooting Spectrum24 terminal initialization failures

!

Running the self test function

!

Self test summaries

!

Keyboard test

!

Running memory transfer

!

Scanning problems.

Error Messages If ERR3000 is loaded in the system configuration, the terminal displays the following messages to indicate error conditions that affect system performance. A message is usually accompanied by one or more beeps, after which the system returns to its previous status. The application can change the actual wording of the messages or disable messages. The messages listed in Table 7-1 are representative. Refer to the Series 3000 Application Programmer's Guide or your application guide for additional information.

7-1

Page 63

PDT 6100 Product Reference Guide

Table 7-1. Error Messages Message

Explanation

Double Key Error

Two or more keys were pressed at the same time. This does not include boot sequences (refer to Chapter 5, Operating the PDT 6100 Series, for boot sequences).

Low Battery

The battery pack should be recharged or replaced as soon as possible.

Dead Battery

Replace or recharge the battery pack immediately. After this message is displayed, the system shuts off. You may not be able to power it on again until the battery pack is charged.

Power Fault

The last power off was caused by a power failure. This occurs, for example, if the battery pack is removed while the terminal is on or the batteries fail suddenly.

Troubleshooting Start-up Failure Problems are most frequently start-up failures. If cold booting the terminal does not start the application successfully, either the application, the system software, or the system is malfunctioning. If you can boot the system to command mode, try the following: !

Use Program Loader to download a new version of the software to NVM. This procedure is described in Chapter 3, Batch and Spectrum One Terminal Setup for batch or Spectrum One terminals, or Chapter 4, Spectrum24® RF Terminal Setup for Spectrum24 terminals.

!

Use Self Test to check whether system hardware is operational. The Self Test procedure is described later in this chapter. After downloading new software, warm boot the terminal as described in Chapter 5, Operating the PDT 6100 Series.

Boot Failure Messages During a cold boot, the system briefly displays a status line for each driver as it loads, in the format: 0:Driver

7-2

#.##

Page 64

Error Recovery and Troubleshooting

The line shows a status value, usually 0, followed by the name and version number of the driver. If the system halts at one of these lines and displays a status value other than 0, the displayed device driver did not load properly. If such a failure occurs, cold boot the terminal again. If this does not solve the problem, call Symbol Customer Support. More troubleshooting information is found in the documentation listed in Related Publications.

Spectrum24 Terminal The command mode troubleshooting procedures utilized by 6100 batch or Spectrum One terminals are not available to terminals operating in a Spectrum24 network environment. Typical initialization and operating problems and solutions for Spectrum24 terminals are listed in Table 7-2. Table 7-2.Troubleshooting Spectrum24 Terminals Problem

Explanation/Action

Out of range

Terminal is out of the Access Point’s range. If you move the terminal during initialization, the terminal may be out of range of the AP and unable to complete the initialization process. Move back in range and repeat the initialization process.

Startup process fails

Boot server type (BOOTP or DHCP) doesn’t exist. Verify that the boot server is operating and able to respond to TCP/ IP, BOOTP, or DHCP requests from the terminal.

Low battery message.

Place the terminal in a cradle and recharge battery. OR Power terminal off and replace battery.

Battery is dead.

Battery not replaced after receiving low battery message or terminal left on for more than 24 hours. Recharge or replace the battery.

Terminal disassociated from Access Point.

Application does not respond to interactive operations. Applications using internal batch mode continue to function until required to transmit via radio, then fail to work. No message displayed.

7-3

Page 65

PDT 6100 Product Reference Guide

Self Test Function PDT 6100 terminal includes a series of self tests which verify that terminal hardware components are operating properly. Run self test if you suspect a problem with the hardware. Except for keyboard testing, no operator input is necessary after selecting a test screen.

Running the Self Test Access the Self Test function from the Command Mode menu: 1. Boot to command mode (refer to Chapter 5, Operating the PDT 6100 Series for boot sequences). 2. On the Command Mode screen, use the <UpArrow> or <DownArrow> to scroll through the options. 3. Highlight Screen Test and press <Enter>.

Self Test Summaries The Self Test is divided into five functions or screens: Config Screen 1 - Reports the terminal type and version, time, date, main battery status, current power source, and status of the serial ports when a loopback connector is used. Config Screen 2 - Reports information on the keyboard and display. If a laser scanner is attached, the test reports if the trigger is pulled or not. If a wand scanner is attached, the test reports whether the wand is scanning black or white. Memory Screen - Tests ROM, RAM, and EMS (Expanded) memory, and reports the amount of RAM and EMS. Fill Screen - Fills the entire screen with a test pattern to verify that the entire screen displays. Set RTC Screen - Sets the time and date settings of the real-time clock.

7-4

Page 66

Error Recovery and Troubleshooting

Keyboard Test Keyboard testing can be performed while the terminal displays Config Screen 1 results. Test any keys except Clear and PWR. When you press a key, the corresponding key code is displayed on the top row to the right of the test name. Table 7-3, Table 7-4, and Table 7-5 list the codes for the 22-key, 35-key, and 46-key keyboards, respectively. Table 7-3. 22-Key Keyboard Test Codes Key

Test Code

Key

Test Code

Left Arrow

00

6

14

Right Arrow

01

5

13

Up Arrow

03

4

12

Down Arrow

04

3

17

FUNC

05

2

16

SEND

06

1

15

-

07

0

19

9

11

.

18

8

10

ENTER

20

7

09

7-5

Page 67

PDT 6100 Product Reference Guide

Table 7-4. 35-Key Keyboard Test Codes Key

7-6

Test Code

Key

Test Code

Alpha

0

M

18

Space

1

N

19

Shift

2

9

22

Func

4

8

21

Ctrl

5

7

20

A

6

6

26

B

7

5

25

C

8

4

24

D

9

3

30

E

10

2

29

F

11

1

28

G

12

0

32

H

13

Backspace

27

I

14

X

31

J

15

Z

33

K

16

Enter

34

L

17

Page 68

Error Recovery and Troubleshooting

Table 7-5. 46-Key Keyboard Test Codes Key

Test Code

Key

Test Code

CONTROL

3

V

26

SHIFT

2

W

27

A

5

X

28

B

6

Y

29

C

7

Z

30

D

8

Up Arrow

33

E

9

Down Arrow

34

F

10

0

44

G

11

1

41

H

12

2

42

I

13

3

43

J

14

4

38

K

15

5

39

L

16

6

40

M

17

7

35

N

18

8

36

O

19

9

37

P

20

BKSP

31

Q

21

SPACE

47

R

22

FUNC

1

S

23

.

32

T

24

ENTER

45

U

25

7-7

Page 69

PDT 6100 Product Reference Guide

Exiting Self Test The test loop continues updating the time and battery status and processing keystrokes. To end the test, press <Clear>.The display returns to the Command Mode menu.

Memory Transfer Program Command Mode includes a memory transfer utility that transfers data from a terminal to a host PC for program troubleshooting. Programmers can analyze an application using tools provided in the Series 3000 Application Development Kit and described in the Series 3000 Application Programmer’s Reference Manual.

Hardware Setup 1. Turn OFF the terminal and host PC. Disconnect or unplug the cradle, if used.

Caution Always turn off the terminal before attaching or removing cables. 2. Connect the terminal and host PC using the communications/charger cable: a. Plug the CCC’s RJ41 connector in the terminal’s base. b. Plug the CCC’s DB-9 connector in the host PC’s communications port.

33222013.eps

Figure 7-1. CCC Connections for MemoryTransfer OR

7-8

Page 70

Error Recovery and Troubleshooting

3. Connect the host to the CRD 6100: a. Plug the null modem’s connector in the cradle’s communications port. b. Plug the other connector in the host’s communications port. c. Place the terminal in the cradle. 4. Power on the host PC. 5. Plug in the cradle, if used.

33222011.eps

Figure 7-2. Cradle Connections for MemoryTransfer

Set Communications Parameters Host 1. Start the Communications program on the host PC. 2. Set up the host communication parameters (these parameters must match the terminal’s parameters). At the DOS prompt on the host, enter: RCVHEX <filename.hex> <baud rate> <comport#>

Typical parameters are: 38400 bps 7 bit data Odd parity Xon/Xoff flow control

7-9

Page 71

PDT 6100 Product Reference Guide

Terminal 1. Boot the terminal to Command Mode (refer to Chapter 5, Operating the PDT 6100 Series for the appropriate key sequence). 2. Select the Memory Transfer function from the Command Mode menu. Use <UpArrow> or <DownArrow> to scroll through the command mode options until Memory Transfer is displayed, and press <Enter>. 3. Select the range of memory to transfer by pressing the first letter of the desired range (All, Range, or None), or use the <UpArrow> or <DownArrow> and press <Enter>. If you select All, the program skips to the range verification screen (step 7). If you select Range, the screen displays: RAM Use Arrow Keys Start End 00000 9FFFF

4. Specify a range of RAM by setting the Start and End addresses. "

Use <RightArrow> and <LeftArrow> to move the cursor to the digit to be changed

"

Use <UpArrow> and <DownArrow> to change the values.

Type a range and press <Enter>. 5. Specify a range of NVM to transfer. Choose All or None. 6. If the system has EMS installed, it prompts for the range to transfer (otherwise, the program skips this screen): EMS Use arrow keys Start End

The range is specified in page numbers (16 KB per page). Use <RightArrow> and <LeftArrow> to move between the Start and End values. Use <UpArrow> and <DownArrow> to change the page number value. Set the range and press <Enter>.

7-10

Page 72

Error Recovery and Troubleshooting

7. The terminal displays a range verification screen. For example: RAM 0000 3FFF NVM C839 DFFF EMS None Correct?

If the values are correct, press <Enter>. If the values are not correct, press <Clear> to clear the fields and select new values. 8. Specify the baud rate. Use the <UpArrow> and <DownArrow> to scroll through the list of baud rates until the correct rate is displayed, and press <Enter>. (Flow control may be necessary at 38400 bps and higher.) 9. Specify the data bits. Press <7> or <8>, or use <UpArrow> and <DownArrow> to display 7 or 8, and press <Enter>. Note: If you select 8 data bits, the program selects No parity and skips the next screen. 10. Specify parity type. Use <UpArrow> and <DownArrow> to display a parity option, or press the first letter of a parity option (Even, Odd, None, Space, or Mark) and press <Enter>. 11. Set flow control. Use <UpArrow> and <DownArrow> to display the flow control options, or press the first letter of an option (None, Xon/Xoff, or RTS/CTS) and press <Enter>.

Start Communications 1. The terminal is ready to send the data to the host PC and displays: Comm Parameters Start? <ENT>

2. Verify that the host is ready to receive data. 3. Press <Enter> on the terminal. While data is being transferred, the terminal displays a report of the 1 KB range being transferred: Memory Transfer Sending: XXXX

7-11

Page 73

PDT 6100 Product Reference Guide

The display is updated for every 1024 bytes (1 KB) of memory. 4. When the transmission completes or aborts, the terminal displays the transmission status screen: Memory Transfer Status

0000

A status of 0000 (all zeros) indicates that the transfer was successful. Any other status indicates failure. Refer to Appendix C for communications status codes which indicate the source of the error.

End Communications To return to the Command Mode main menu, press <Clear>. Then take whatever corrective action is necessary, and reboot the terminal.

Internal Modem Problems If you are having difficulties with your internal modem, please check the following before returning your product: • Connection to the telephone network is correct. • Any necessary special requirements such as dialing 9 and ignoring dial tone have been considered in the event of using a PBX. • Firmware settings described in the Series 3000 Application Programmer’s Guide have been configured correctly.

Scanning Problems What If ... Nothing happens when you follow the operating instructions? !

Check the system power.

!

Make sure the scanner is programmed to read the symbology you are trying to read.

!

Check the bar code to make sure it is not defaced. A defaced 1-D bar code may not be readable by any scanner.

!

Check to see if you are scanning from the proper distance.

!

Try scanning a test symbol of the symbology you are trying to read.

7-12

Page 74

Error Recovery and Troubleshooting

Your terminal operates but scanned data is not displayed correctly? !

Check the system power.

!

Check that the communication parameters (baud rate, parity, stop bits, etc.) are set properly for the receiving device.

The laser does not activate? !

You may have exceeded the allowable amount of scanning activity within the limits of your laser class of operation; in this case, wait for a short interval before scanning again.

!

You may be scanning in an inappropriately hot environment. If so, remove the equipment from that environment, or allow the laser to cool down.