Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 7 of 12

PDT 6100 Series Product Reference Guide, pages 42 to 51

Pages 42 to 51 of 108

The original document is the PDF (1.5 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Symbol PDT-6100, Symbol PDT-6110 and Symbol PDT-6146

Page 42

Operating the PDT 6100 Series

Figure 5-2. PDT 6100 Standard 35-Key Keyboard

SCAN

A

CTL

B

C

D

CLR

E

F

G

H

I

J

K

L

M

N

O

P

Q

R

S

T

U

V

W

X

Y

Z

7

8

9

4

5

6

1

2

3

.

0

ENTER

FNC SHF BSP

Figure 5-3. PDT 6100 Standard 46-Key Keyboard 5-9

Page 43

PDT 6100 Product Reference Guide

Modifier Keys The Shift, Alpha, Function, and Control keys are modifier keys. When pressed individually or in certain combinations, these keys change the keyboard state and possibly the character produced by the character key subsequently pressed. For example: !

Pressing <Alpha> causes the numeric keys to produce letters.

!

Pressing <Func> followed by <Ctrl> produces Alt characters, with the same effect as pressing the Alt key on a PC.

!

Pressing <Func> and a scanner trigger enables that trigger for scanning. Refer to the section Scanning on page 5-12 for more information.

!

The opposite trigger is another Alpha key (Alpha Shift), producing capital letters. It is active only when held down.

!

The <Alpha> key on the keyboard affects all succeeding character keys until <Alpha> is pressed again. The other modifier keys affect only the next character key.

Refer to Appendix B, Keyboard Layouts for the characters and operations produced by pressing a sequence of modifier keys on the standard terminal keyboards. These key assignments can be changed by an application. Refer to your application documentation for any special key assignments.

Cancelling a Modifier Key To cancel the effect of a modifier key, press it again.

Keyboard State The cursor’s shape indicates the current keyboard state, unless changed by the application. The standard cursor shapes are shown in Table 6-2 on page 6-3.

Key Descriptions Most of the keys are self-explanatory. Letter keys produce letters, number keys produce numbers. Keys that perform special functions are described in Table .

5-10

Page 44

Operating the PDT 6100 Series

Table 5-1. Special Keys 22-Key Key Name

35-Key Key Name

46-Key Key Name

CTRL (Control)

CTL (Control)

Invokes the control command.

FUNC

FUNC (Function)

FUNC (Function)

Invokes the function command for certain utilities, such as turning on the back light. " Press FUNC and the corresponding numeric key to produce function keys F1 to F10. " Press FUNC, then to scroll left and FUNC to scroll right. " Press FUNC then BKSP to enter a blank space.

BACK

BKSP (Backspace)

BKSP (Backspace)

Erases information entered on the display one character at a time. Information erased this way cannot be recovered. This key is also used to produce a break by pressing CTL, BKSP.

PWR (Power)

PWR (Power)

Turns the terminal on and off.

CLEAR

CLR (Clear)

Partially or completely escapes from an application level or screen. CLR also clears all data typed from the display.

SHIFT

SHF (Shift)

Accesses the shifted keyboard.

ENTER

ENTER

Places entered data into the terminal’s memory.

ENTER

Description

Move the cursor up, down. Press FUNC then to scroll left; press FUNC then to scroll right. Arrow key use depends on the application. Moves the cursor up, down. Move the cursor left, right.

SEND

ALPHA

Shifts the keyboard to produce alphabetic characters.

SPACE

Places a blank space on a line of the display. Allows you to send data to the host.

5-11

Page 45

PDT 6100 Product Reference Guide

Scanning Before scanning can occur, the application must implement routines to support bar code scanning. For information on scanning applications and on programming the scanner, refer to the Series 3000 Application Development Kit. The PDT 6100 terminal supports an integrated 1-D standard scanning device.

Setting the Trigger The integrated scanner has a unique trigger that the operator can configure. To use the integrated laser scanner: 1. Power on the system and scanner by pressing <

> (PWR) or the scanner trigger.

2. Lift up and turn the scan element on the top of the terminal to the preferred orientation for scanning (refer to Figure 5-4). The scan head turns only toward the back of the terminal.

Figure 5-4. Positioning the Integrated Scanner 3. Lock the scan head in position, facing the side of the terminal. 4. To select the trigger, press the <FUNC> key and the trigger you are most comfortable using. The other trigger defaults to an ALPHA shift key. Depending on the application, the terminal may beep to indicate a trigger is selected.

5-12

Page 46

Operating the PDT 6100 Series

Using the Integrated Laser Scanner To scan: 1. Power on the system and scanner by pressing the < > (PWR), the SCAN bar, or a trigger. The Scan LED lights yellow if scanning is enabled and the laser is on. 2. Turn the scanner to the direction you wish to scan. The scanner turns toward the back of the 6100. 3. Point the PDT 6100 at the bar code and press the scan bar or a side trigger.

Figure 5-5. Scanning a Bar Code 4. Ensure that the scan beam crosses all bars and spaces on the symbol, as shown below. Right

Wrong

5. Hold the scanner farther away for larger symbols, and closer for symbols with bars that are close together. 6. The LED turns from yellow to green for successful decodes. The PDT 6100 may also beep.

5-13

Page 47

PDT 6100 Product Reference Guide

Aiming: Hold at an Angle Do not hold the 6100’s scan window directly over the bar code. Laser light reflecting directly back into the scan window from the bar code is known as specular reflection. This strong light can “blind” the scanner and make decoding difficult. The area where specular reflection occurs is known as a “dead zone”. You can tilt the 6100 up to 55° forward or back and achieve a successful decode. Practice quickly shows what tolerances to work within.

Figure 5-6. Scanning Angle and Specular Reflection

Range Any scanning device decodes well over a particular working range, minimum and maximum distances from the bar code. This range varies according to bar code density and scanning device optics. Scanning within range brings quick and constant decodes; scanning too close or too far away prevents decodes. You need to find the right working range for the bar codes you are scanning. The best general advice is: !

Hold the scanner farther away for larger symbols.

!

Move the scanner closer for symbols with bars that are close together.

!

Start scanning at a distance from the bar code, not from direct contact. If the bar code does not readily decode, move the scanner in closer.

5-14

Page 48

Operating the PDT 6100 Series

The best way to specify the appropriate working range is through a chart called a Decode Zone (Figure 5-7). A decode zone simply plots working range as a function of minimum element widths of bar code symbols. Note: Typical performance at 68 F (20 C) on high quality symbols.

SE 900 STANDARD

In. 15 cm 38.1

10

25.4

5

12.7

0

0

5

12.7

10

25.4

15

38.1

5 mil 2.2

4.8

7.5 mil 1.8 2.0

6.2 100% UPC

25.0

55 mil

5 12.7

F i e l d

20.0

40 mil

In. 0 cm 0 o f

13.0

20 mil

* * *

W i d t h

10 25.4

15 38.1

26.0 20 50.8

25 63.5

30 76.2

Depth of Field

* Minimum distance determined by symbol length and scan angle Figure 5-7. PDT 6100 Decode Zone

5-15

Page 49

PDT 6100 Product Reference Guide

Running Communications Communicating with a Host The 6100 communicates with a host or printer through the CRD 6100 or the Charging and Communications Cable (CCC). To communicate with a host or printer through the CRD 6100: 1. Set up the cradle as described in Connecting the Cables on page 2-3, or in the CRD 6100 Quick Reference Guide. 2. Place the 6100’s base in the cradle. Press the top of the 6100 against the cradle back until it is firmly seated. The terminal’s Charging LED flashes yellow and then lights solid yellow when the terminal is securely placed in the cradle. 3. Start the communications program on the host and the 6100.

33222011.eps

Figure 5-8. PDT 6100 Seated in CRD 6100

5-16

Page 50

Operating the PDT 6100 Series

To communicate with a host through the CCC (refer to Figure 5-9): 1. Plug the CCC‘s 10-pin RJ41 connector in the 6100’s base. 2. Connect the DB-9 connector to the host’s serial (COMM) port. 3.

Start the communications program on the host and the 6100.

CCC DB-9 Connector

RJ41 Connector

33222013.eps

Figure 5-9. Using the CCC to Connect the PDT 6100 to a Host PC (shown) or Printer

Radio Communications The PDT 6110 operates in a Symbol Spectrum One RF network; the PDT 6140 operates in a Symbol Spectrum24 RF network. The Status LED indicates the state of the 6100’s connection to either of the RF networks: Off indicates that the radio is working and associated with an access point (Spectrum24) or base station (Spectrum One). (The Status LED indication of RF activity is presently not available.)

Flashing green once per second indicates that the radio is out of range or not associated with an access point or base station. (The Status LED indication of RF activity is presently not available.)

Refer to the network documentation for more information on operating the PDT 6100 in the specific RF environment.

5-17

Page 51

PDT 6100 Product Reference Guide

Communicating With a Printer To connect the terminal to a printer, use the CCC or the appropriate printer cable. The following directions apply to the CCC: 1. Plug the CCC’s 10-pin RJ-41 connector into the PDT 6100 terminal’s serial port (refer to Figure 5-9). 2. Plug the DB-9 connector in the communications port on the printer. 3. Start the communications program.

5-18