Chapter 4 Maintenance And Specifications Introduction This chapter explains how to maintain your scanner and the specifications for it.

Maintenance •

Do not allow any abrasive material to touch the scanner window.

•

Remove any dirt particles with a damp cloth.

•

Wipe the scanner window using a damp cloth, and if necessary, a non-ammonia based detergent.

•

Do not spray water or other cleaning liquids directly into the scanner window.

•

If the contacts between the scanner and cradle become dirty, clean them with either a pencil eraser or a cotton swab dampened with alcohol.

•

If a significant decrease in battery life is noticed and does not correspond to increased usage, consider replacing the battery.

4-1

Page 62

P460/P360 Memory Scanners Product Reference Guide

Troubleshooting Refer to Appendix C, Messages and Error Codes for additional troubleshooting information. Table 4-1. Troubleshooting Table Problem

Possible Causes

Possible Solutions

Scanner won’t power up.

Battery not charged.

Charge or replace the battery in the scanner

Battery not installed properly.

Ensure the battery is installed properly. See Changing the Battery on page 2-7.

LED on base is always Base is locked up on.

Cycle power (power off then on) to the base.

Nothing happens when you follow the operating instructions, or the scanner displays erratic behavior (laser does not come on, scanner emits frequent beeps).

No power to the scanner.

Check the system power. Ensure the power supply is connected, if your configuration requires a power supply.

No laser beam when trigger is pressed.

Failed to download firmware.

Reset the scanner (remove and reinsert the battery, see Changing the Battery on page 2-7) and try scanning again.

Scanner is locked up.

Reset the scanner (remove and reinsert the battery, see Changing the Battery on page 2-7) and try scanning again.

Laser comes on but the Scanner is not symbol does not programmed for the decode. correct bar code type.

Ensure the scanner is programmed to read the type of barcode you are scanning.

Symbol decodes but data is not transmitted to the host.

4-2

Interface/power cables Check for loose cable connections at the cradle, are loose. AC power supply, or host device.

Bar code symbol is unreadable.

Check the symbol to ensure it is not defaced. Try scanning test symbols of the same bar code type.

Distance between scanner and bar code is incorrect.

Move the scanner closer to or further away from the bar code.

Scanner is not programmed for the correct host type.

Scan the appropriate host type bar code.

Page 63

Maintenance And Specifications

Table 4-1. Troubleshooting Table (Continued) Problem

Possible Causes

Possible Solutions

Scanned data is Scanner is not incorrectly displayed on programmed to work the host. with the host.

Ensure the proper host type is selected. Check the scanner host type parameters or editing options: • For RS-232, ensure the scanner’s communication parameters match the host’s settings.

The scanner emits error beeps after decoding a bar code.

Check that the cradle is powered up and that its cable connections are secure. See Setting Up the Cradle on page 2-4.

Cradle is not powered up or cable connections are not secure.

Scanner is too far from Move closer to the base and retransmit. the base for proper transmission.

Received a communication error beep while using a Synapse cable.

Previously scanned data not transmitted to host.

Ensure you are within the proper RF transmission range.

The cables connected to the cradle were not connected in the correct sequence.

Before power is applied to the cradle, the Synapse cable must be connected to the cradle AND the flying power lead plugged in. See Using A Synapse Cable with the cradle on page 2-9 for more information

4-3

Page 64

P460/P360 Memory Scanners Product Reference Guide

Table 4-1. Troubleshooting Table (Continued) Problem

Possible Causes

Possible Solutions

The scanner does not Bar code symbol is scan the programming unreadable. bar codes in this guide. Distance between scanner and bar code is incorrect.

Check the symbol to ensure it is not defaced. Try scanning test symbols of the same bar code type.

Scanner is not in scan mode.

For MCL-Designer generated applications, put the scanner into “Scan Parameter” mode in the system menu (see Scan Parameters on page 314). For the default application running on a previous version of the following firmware:

Move the scanner closer to or further away from the bar code.

P460/P360 1 MB

Revision N or lower, such as M

P460/P360

Revision H or lower, such as G

4 MB or 8 MB put the scanner into “Scan Parameter” mode in the system menu (see Scan Parameters on page 3-14). For instructions on how to check the scanner’s firmware version, see Version on page 3-16. The PC cannot download an application to the scanner.

4-4

Incorrect cable connection.

Check to ensure you are using an RS-232 cable. The application cannot be downloaded to a scanner using a Synapse cable.

No power to the scanner.

Check to ensure the power supply is connected to the base. If the problem continues, cycle power to the base (power off then on).

Page 65

Maintenance And Specifications

Table 4-1. Troubleshooting Table (Continued) Problem The Scanner will not load my ADF rule.

Possible Causes

Possible Solutions

The scanner is running Software download or scanning a bar code sheet an MCL-Designer while the scanner is running an MCL-Designer generated application. generated application • Erase the MCL-Designer application from the scanner’s memory by scanning the “Reset Default Application” bar code on page 3-17. • The default application is now reinstalled and an ADF rule can be loaded.

Note: If after performing these checks the symbol still does not scan, contact your distributor or call the Symbol Support Center. See Symbol Support Center on page page xi for the telephone number.

Optional Accessories Optional accessories include various stands and holders, which are supplied at extra cost. One such optional accessory is the IntelliStand. When the scanner is inserted in the IntelliStand, it enables hands-free presentation scanning. It permits the Phaser to scan continuously and automatically read a bar code when one is presented in front of the scanner without an operator pulling the trigger. The Phaser must be operating from a cable with an external power supply to work with the IntelliStand, as it cannot work with battery power under these conditions. For more information about the IntelliStand, refer to the IntelliStand Quick Reference Guide, p/n 70-11567-xx.

4-5

Page 66

P460/P360 Memory Scanners Product Reference Guide

Technical Specifications Table 4-2. Technical Specifications for P460/P360 1D Scanner Item

Description

Decode Capability

UPC/EAN, Bookland EAN, Code 11, Code 39, Code 39 Full ASCII, Trioptic Code 39, Code 93, Codabar, Interleaved 2 of 5, Code 128, EAN 128, Discrete 2 of 5, MSI Plessey, and Coupon Code with auto-discriminate between all of the above code types except for Code 39 and Code 39 Full ASCII.

Scanner Beeper Operation

User-selectable: Enabled, Disabled.

Scan Repetition Rate

35 (± 5) scans/sec (bidirectional)

Roll (Skew) Tolerance

± 30° from normal

Pitch

± 65° from normal

Yaw

± 60° from normal

Decode Depth of Field

See P460/P360 1D Scanner Decode Zone on page 3-25.

Print Contrast Minimum

20% absolute dark/light differential, measured at the wavelength of the laser diode.

Ambient Light Immunity Artificial Lighting

450 ft. candles 4844 lux

Sunlight

10,000 ft. candles107,644 lux

Operating Temperature

P460: 32° to 104°F0° to 40°C P360: -4° to 122°F-20° to 50°C

Storage Temperature

-40° to 158°F-40° to 70°C

Humidity

5% to 95% (non-condensing)

Durability (Scanner)

P460: 5-ft. (1.5 m) P360: 6-ft. (1.8 m) Drops to concrete over entire temperature range

Sealing

P360: All components sealed to IP 54 specification against wind blown dust and rain

Dimensions Height

7.0 in. (17.8 cm)

Width

9.2 in. (13.5 cm)

Depth

3.5 in. (9.8 cm)

Laser Classifications

4-6

CDRH Class II EN 60825 Class 2 IEC 825 Class 2

Page 67

Maintenance And Specifications

Pin-outs Cradle The following table shows the pin-outs for both COM1 and COM2 on the cradle. Table 4-3. Cradle Pin-outs Pin

Cradle

1

BREQ

2

VCC (out of cradle)

3

Ground

4

Synapse Data

5

Synapse Clock

6

RXD (into cradle)

7

TXD (out of cradle)

8

BACK

9

CTS

10

RTS

4-7

Page 68

P460/P360 Memory Scanners Product Reference Guide

Scanner The following table shows the pin-outs for the scanner. Table 4-4. Scanner Pin-outs Pin

Scanner

1

Not Used

2

Power (+9V) 1

3

GND

4

Synapse Data

5

Synapse Clock

6

RXD (into scanner)

7

TXD (out of scanner)

8

Enable Charging 2

9

CTS

10

RTS

1. Battery Charging:

Requires +9V @:

No

Yes

250mA

1A

2. If Pin 8 is connected to Pin 2 the scanner battery charges; make sure you use a +9V @ 1 Amp power supply. If Pin 8 is not connected to Pin 2, the scanner operates but the scanner battery does not charge.

4-8

Page 69

Maintenance And Specifications

Beeper Indications Table 4-5. Beeper Indications Beeper Sequence

Indication

Standard Use Short high tone

A bar code symbol was decoded (if decode beeper is enabled).

4 Beeps - long low tone

A transmission error has been detected in a scanned symbol. The data is ignored. This occurs if a unit is not properly configured. Check option settings.

5 Beeps - low tone

Convert or format error.

Hi/hi/hi/lo tone

RS-232 receive error.

4 Beeps - short hi

Battery requires recharging.

Short low/Short high tone The Scanner detected external power supplied to it by the cradle or a cable. Short high/Short low tone External power has been removed from the scanner.

Parameter Menu Scanning Short high tone

Correct entry scanned or correct menu sequence performed.

Long low/Long high tone

Input error, incorrect bar code or “Cancel” scanned, wrong entry, incorrect bar code programming sequence; remain in program mode.

Hi/lo tone

Keyboard parameter selected. Enter value using bar code keypad.

Hi/lo/hi/lo tone

Successful program exit with change in the parameter setting.

4-9

Page 70

P460/P360 Memory Scanners Product Reference Guide

4-10