The text of a manual · part 8 of 23
P460/P360 Memory Scanners Product Reference Guide: Chapter 3 Operation, pages 53 to 60
Pages 53 to 60 of 198, from P460/P360 Memory Scanners Product Reference Guide
The original document is the PDF (1.9 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Symbol P460
Page 53
Operation
6/9
7/9
8/9
9/9
RESET SCANNER
3-21
Page 54
P460/P360 Memory Scanners Product Reference Guide
Scanning The scanner ships with the default application and default parameters that is ready-to-use right out of the box. If this is not what you need for your application, refer to the MCL Designer Manual for programming instructions and Chapter 5, Parameter Menus for scanning and communications parameters. If you need assistance, contact your local supplier or Symbol Support Center. 1. If you are using the scanner in corded mode, make sure all cable connections are secure. Otherwise, make sure the battery is sufficiently charged. 2. Make sure the bar code is in the correct scanning range. Aim and press the trigger. The scanner has read the symbol when: •
You hear a beep.
•
The LED above the screen turns green.
•
The red laser turns off.
Figure 3-1. Scanning a Bar Code
Scan the Entire Symbol •
Your scan beam must cross every bar and space on the symbol.
•
The larger the symbol, the farther away you should hold the scanner.
•
Hold the scanner closer for symbols with bars that are close together.
•
A short, high tone beep indicates a good decode.
3-22
Page 55
Operation
Right
Wrong
Hold at an Angle Do not hold the scanner directly over the bar code. Laser light reflecting directly back into the scanner from the bar code is known as specular reflection. This strong light can “blind” the scanner and make decoding difficult. The area where specular reflection occurs is known as a “dead zone.” You can tilt the scanner up to 65° forward or back and still achieve a successful decode. Simple practice quickly shows what tolerances to work within.
65
65
Shaded area represents _2 ) dead zone (+ Scan Beam
Scan Beam
Bar Code
Bar Code
Bar Code
Figure 3-2. Maximum Tilt Angles and Dead Zone
3-23
Page 56
P460/P360 Memory Scanners Product Reference Guide
Test Symbols To ensure your scanner is working properly, try scanning the following bar codes. If you have trouble, refer to Troubleshooting on page 4-2.
CODE 128
UPC
3-24
Page 57
Operation
P460/P360 1D Scanner Decode Zone
15.6 in. 39.6 cm 10 in. 25.4 cm 5 in. 12.7 cm 0 in. 0 cm 5 in. 12.7 cm
5 mil
Width
Of Field
10 in. 25.4 cm
7.5 mil 10 mil
15.6 in. 39.6 cm
100% UPC 15 mil 20 mil 40 mil 55 mil
0 in. 0 cm
5 in. 12.7 cm
10 in. 25.4 cm
15 in. 38.1 cm
20 in. 50.8 cm
25 in. 63.5 cm
30 in. 76.2 cm
35 in. 88.9 cm
40 in. 101.6 cm
45 in. 114.3 cm
Distance From Front Of Scanner
Figure 3-3. P460/P360 1D Scanner Decode Zone
3-25
Page 58
P460/P360 Memory Scanners Product Reference Guide
Keypad Operation Instead of scanning a bar code, you can enter the bar code data using the keypad on the top of the scanner. By default, this feature is enabled. To disable alphanumeric data entry via the keypad, go to the symbologies tab inside 123Scan and remove the “X” from the check box next to “Keypad”. (This does not disable the quantity entry feature discussed in Eliminating Repetitive Scanning on page 3-4.) For additional information on 123Scan, see 123Scan on page 3-17. To enter numeric data, type the numeric value desired and press <ENTER>. A beep lets you know that the entry was accepted. See Figure 3-4 on page 3-27. To enter alpha characters, press the <Mode> key once to put the scanner in Alpha Mode. Numeric buttons 1 through 9 are associated with the alpha characters. For example, the letters A, B and C are located on numeric button 7. Press the button with the letter you desire - once for the letter A, twice for the letter B, or three times for the letter C. You can continue entering alpha characters or switch to numerics. Press <ENTER> to save or send the data. To return to numeric entry mode after entering alpha characters, press the <Mode> key again. For example, to manually enter 17ABF5, do the following steps: Data
Action
1
Press numeric button 1.
7
Press numeric button 7.
A
Press <MODE> button once, then numeric button 7 once. Wait for one second (you will hear a low pitched beep).
B
Press numeric button 7 twice.
F
Press numeric button 8 three times.
5
Press <MODE> button once, then numeric button 5 once, then <ENTER>.
Every time you press the button with the letter you desire, you hear a low-pitched beep to let you know that the entry was registered. Although the entry is registered, it has not been
3-26
Page 59
Operation transferred to the host yet. A high-pitched beep lets you know that the entry has been transferred to the host. To return to numeric mode, press the Mode key again. Pressing the Enter key saves the data. To put a decimal point (.) into numeric data, type in the numbers before the decimal point, then press the mode key, press the decimal, and press the mode key again. Now resume typing in the values to the right of the decimal. To enter a dash (-), press the mode key once, then the zero (0) key twice. To enter a blank space ( ), press the mode key once, then the zero (0) key three times. The Function key in combination with a numeric key can be programmed to launch an operation, such as allowing you to review records. To use the Function key to review records, press the <FUNC> key, release it, and then press the <2> key. For more information on how to program these keys for additional tasks and operations, refer to the MCL Designer User’s Guide p/n 70-37689-XX.
Figure 3-4. Scanner Keypad 3-27
Page 60
P460/P360 Memory Scanners Product Reference Guide
3-28