Page 43
Operation
App. Control App. Control allows you to control your application, specifically, load new system application files on your scanner, reset your default applications, etc. You can load a new application/file or system code by either scanning the appropriate bar code or entering the appropriate keypad value as indicated on the display.
Option 0. Load App / File
Description Puts the scanner into a mode to receive MCL-Designer application downloads, file updates, and MCL-Link commands from the host. To enter this mode using the key pad, select this option on the system menu. The following screen displays: Load New App/File <Enter>=Yes <BK>=No OR To enter this mode from an application without entering the system menu, scan the bar code below.
Load New Application/File
Status: Connect unit to host When this screen displays, the scanner is ready to accept the download. On the PC Utility, initiate the download. After downloading is complete, the system menu is exited and the application initiated. To exit this mode and prevent the download of a new application, press the <FUNC> then <BK> keys.
3-11
Page 44
P460/P360 Memory Scanners Product Reference Guide
Option 1. Set Default App
Description Reinstalls the default application and returns all parameters to their factory settings (values listed in Table 5-1). The default application overwrites any MCL-Designer application and/or ADF rules. This option may be used to restore functionality to a scanner which has been loaded with a defective application. To enter this mode using the key pad, select this option on the system menu. Prior to resetting the default application, the user is prompted to confirm this operation: Reset Default App? <Enter>=Yes <BK>=No
Press the <ENTER> key to confirm the choice (Yes) or the <BK> key to cancel the choice (No). If you entered “Set Default App” from the System Menu, upon resetting the default application, you will return to the System Menu. OR To enter this mode from an application without entering the system menu, scan the bar code below.
Reset Default Application (Clears previously programmed ADF rules and/or MCL-Designer applications) If you entered the “Set Default App” mode using the bar code above, the default application will automatically be reset, the System Menu exited, and the application re-initiated.
3-12
Page 45
Operation
Option 2. System Code
Description Updates the scanner operating system (Firmware). An RS-232 cable is required. It connects the scanner (not the cradle) to the host. To enter this mode using the key pad, select this option on the system menu. Load New System Code <Enter>=Yes <BK>=No
Press the <ENTER> key to confirm the choice (Yes) or the <BK> key to cancel the choice (No). OR To enter this mode from an application without entering the system menu, scan the bar code below.
System Code
Attach RS232 Cable and Press ENTER
Attach the RS-232 cable and press <ENTER> to start the download.
Scanner ready, On PC start download
After the download is complete, the system menu is exited and the application initiates. To exit this mode and prevent the download of new firmware, press and hold the <ENTER> key for 30 seconds. 9. Back to Main
Returns the user to the system menu.
3-13
Page 46
P460/P360 Memory Scanners Product Reference Guide
Parameter Control Parameter Control allows you to control the scanner parameters such as Scan Parameters and Set Default Params. Option 0. Scan Parameters
Description This feature only works when used with an application generated with MCL-Designer and allows you to program your scanner by scanning the bar codes in Chapter 5, Parameter Menus. Parameters already set in your MCL-Designer generated application can not be overridden by scanning bar codes. When you see the following screen, you can begin scanning parameter bar codes: Scan Parameters <FUNC> <BK> to quit After scanning the desired bar codes, press <FUNC> then <BK> keys to exit this mode.
1. Set Default Param
Restores the default parameters in the scanner. The default parameters overwrite any scanned parameters. Prior to resetting the default parameters, you are prompted to confirm your choice.
9. Back to Main
Returns the user to the system menu.
System Status System Status allows you to perform system checks such as Battery Check. Option 0. Battery Check
Description Checks the battery charge level. Good indicates the battery does not require recharging. Low/Recharge indicates the scanner requires a recharge. When the battery is close to complete discharge, the following message displays: Recharge Battery
9. Back to Main
3-14
Returns the user to the system menu.
Page 47
Operation
Erase File Erase File
Erase File allows you to erase your scanner batch data. It is recommended that data files be transferred from the scanner to the host before erasing. A screen prompts you to indicate which file is being erased. The batch/Inventory application data is always saved in file A. File to Erase? (A-H)
Enter the file name, (the name is a single letter between A and H), then press <ENTER> to erase the file. OR Press * to erase all files.
3-15
Page 48
P460/P360 Memory Scanners Product Reference Guide
Version Version
This option displays the version of firmware (operating system) run by the scanner and the size of the scanner’s memory, such as 1024k (1 MB). For example, the firmware version shown on the display below is NBRVSMAP, also called Revision “P” (which is the last letter of the firmware’s full name). To enter this mode using the keypad, select this option on the System Menu. The following screen displays. Scanner: NBRVSMAP MCL: 4.x Mem: 1024
If you entered “Version” from the System Menu, after 15 seconds or by pressing <ENTER>, you will return to the System Menu. OR To enter this mode from an application outside of the System Menu, scan the bar code below.
Scanner Firmware Version If you entered “Version” using the bar code above, after 15 seconds or by pressing <ENTER>, you will automatically exit the System Menu and re-enter the application.
Return to App Return to App.
3-16
Return to App exits the system menu and returns to the application. To do this, press <9> then <ENTER>.
Page 49
Operation
123Scan 123Scan is an intuitive Windows based utility that allows you to customize your scanner setup and generate Advanced Data Formatting (ADF) rules. An Advanced Data Formatting rule gives you the ability to modify the bar code data before sending it to the host such as appending a carriage return, or some other prefix/suffix value, to the bar code data. This enhances capability between bar code data and your host software, allowing you to program the scanner rather than modifying your host application. The scanner can be programmed via a serial (RS-232) download or by scanning 123Scan generated programming bar codes. Scanner programming is saved in a setup file which can be distributed electronically (Web site, floppy disk, or E-mail). A copy of 123Scan is on the CD included with your scanner. It is also available on the Symbol Web site http://www.symbol.com. Use the web site’s search tool to find “123Scan” and select the P460/360 product line. Note: Advanced data formatting rules created with 123Scan are for use with the default application only and will not work with applications created with MCL-Designer. To download a 123Scan generated ADF rule, scan the bar code below. Place the scanner in its cradle or attach an RS-232 cable. Then initiate the download on the PC utility.
Load 123Scan File
To remove previously programmed ADF rules from the scanner, scan the bar code below.
Reset Default Application (Clears previously programmed ADF rules)
3-17
Page 50
P460/P360 Memory Scanners Product Reference Guide
Suffix Values 123Scan generated programming bar codes for two commonly used suffixes (Enter and Tab) have been included in this Product Reference Guide. To append an Enter key* to the transmitted bar code data, scan all nine (9) ADF rule bar codes and then the Reset Scanner bar code, in that order.
* ASCII value 7013 ADF Rules 1/9
2/9
3/9
4/9
3-18
Page 51
Operation
5/9
6/9
7/9
8/9
9/9
RESET SCANNER
3-19
Page 52
P460/P360 Memory Scanners Product Reference Guide
To append a Tab* to the transmitted bar code data, scan all nine (9) ADF rule bar codes and then the Reset Scanner bar code, in that order.
* ASCII value 7009 ADF Rules 1/9
2/9
3/9
4/9
5/9
3-20