Page 33
Chapter 3 Operation Introduction This chapter covers how to use the Phaser scanner.
Default Applications The Memory Phaser is shipped from the factory with two ready to use default applications: •
Scan and Transmit
•
Batch / Inventory
These applications allow users to scan and view data, enter quantities, manually enter data, and much more. When the unit is powered up, it displays the system start-up banner. Alternatively, the scanner can be reset manually by pressing the <FUNC> key, then the <*> key. When the scanner is powered up or reset, the system banner appears as follows: Symbol Technologies Phaser Memory Scnr
3-1
Page 34
P460/P360 Memory Scanners Product Reference Guide
Initial Powerup After a few seconds, the System Banner is replaced by the system initialization screen. Symbol Technologies Initializing...
After initialization, the scanner enters either the Scan & Transmit mode, or the Batch/ Inventory mode, depending on whether a communications cable is present or not. The default communication protocols are: •
RS-232/Synapse - Scan & Transmit application
•
RS-232/Synapse - Batch/Inventory application
If a Synapse cable is attached, the scanner automatically overrides the default settings.
Batch / Inventory Application The batch/inventory application is a scan-and-store application that allows you to: •
Display and store (Batch) data for transmission later
•
Eliminate repetitive scanning with a quantity entry feature
•
Manually enter alphanumeric data if no bar code is present
•
Review and delete stored records
•
Transmit stored (batch) data to a host.
The scanner automatically detects and switches to batch/inventory mode operation when it is removed from the cradle or its cable is disconnected. The following Batch/Inventory screen appears: SCAN:___________________ __________________
Scanned bar code data is automatically displayed and stored for review/transmission to a host at a later date. If the scanner powers down, pull the trigger or press the <ENTER> key to wake it up.
3-2
Page 35
Operation
Numeric Data Entry The default application also allows you to manually enter data if no bar code is present. By default, this feature is enabled. To disable alphanumeric data entry via the keypad, go to the symbologies tab inside 123Scan and remove the “X” from the check box next to “Keypad”. (This does not disable the quantity entry feature discussed in Eliminating Repetitive Scanning on page 3-4.) With keypad entry enabled (default setting out of the box), press the <ENTER> key after keying in data. During data entry, the <BK> key corrects keying errors digit by digit, and the <FUNC> key then <BK> key combination clears the screen so you can start over. If your entry exceeds 34 characters, the characters will scroll off the visible portion of the screen, but are retained for storage.
Alpha Data Entry To enter alpha characters via the keypad (with keypad enabled, page 3-26), press the <Mode> key once to put the scanner in Alpha Mode. Numeric buttons 1 through 9 are associated with the alpha characters. For example, the letters A, B and C are located on numeric button 7. Press the button with the letter you desire - once for the letter A, twice for the letter B, or three times for the letter C. You can continue entering alpha characters or switch to numerics. Press <ENTER> to send the data. To return to numeric entry mode after entering alpha characters, press the <Mode> key again. For example, to manually enter 17ABF5, do the following steps: Data
Action
1
Press numeric button 1.
7
Press numeric button 7.
A
Press <MODE> button once, then numeric button 7 once. Wait for one second (you will hear a low pitched beep).
B
Press numeric button 7 twice.
F
Press numeric button 8 three times.
5
Press <MODE> button once, then numeric button 5 once, then <ENTER>.
For more information, refer to Keypad Operation on page 3-26. 3-3
Page 36
P460/P360 Memory Scanners Product Reference Guide
Eliminating Repetitive Scanning To eliminate repetitive scanning of identical items, you can enter a quantity prior to scanning a bar code. This quantity entry feature can also be used when manually entering bar code data. To enter a quantity, press the * key. The following screen with a default value of “1” will appear: Quantity: 1^_____________
To enter the value you desire, key in the quantity followed by the <ENTER> key. Next, the bar code data entry screen reappears. Scan the item’s bar code. The scanner sends the bar code data to the host the keyed-in amount of times. For instance, if you type in a quantity of 6 then scan a bar code, the scanner sends that bar code data to the host six times as if the bar code had been scanned six times. If you have accidentally entered this screen, it will automatically be exited after 5 seconds or by pressing the <ENTER> key without entering a quantity.
3-4
Page 37
Operation
Reviewing and Deleting Stored Records While running the Batch/Inventory application, you can review and delete stored data. Press the <FUNC> key, then the <2> key to enter this mode. The following screen appears: CODE: xxxx aaaa/bbbb
Three fields are shown on this screen: xxxx = the data contained within the record (the first 25 characters) aaaa = the index number of the record being viewed bbbb = the total number of records stored in memory Use the up and down arrow keys to scroll through the stored data. Press the <ENTER> key at any time to exit the review records mode.
To select the record being viewed for deletion, press the <BK> key. A confirmation screen displays: Delete (data) <Enter>=Yes <BK>=No
Then press the <Enter> key to delete the selected record or the <BK> key to keep (retain) the record. If a record is deleted, the total number of records (bbbb) displayed on the bottom right of the review screen will not change. For example, if five records have been scanned and stored in memory and the third record is deleted, the review screen will continue to display the total number of records stored in memory as five. But a review of the individual records will show no third record existing. The reviewed records index from the second record (2/5) to the fourth record (4/5), skipping the deleted third record (3/5).
3-5
Page 38
P460/P360 Memory Scanners Product Reference Guide
Transmitting Batch/Stored Data to the Host When you are ready to transmit your stored (Batch) data to the host, press the <FUNC> key, then the <1> key. Then, place the scanner in the cradle or connect a communication cable. Note: When attached to a cable, the scanner will automatically begin running the Scan & Transmit application. The stored (Batch) data will not be transmitted to the host until the <FUNC> key, then the <1> key are entered. When the screen below appears, the scanner is ready to initiate the transfer. You have 30 seconds to either insert the scanner into a cradle or attach a communications cable. If you fail to do so, a retry screen will appear. Status: Connect unit to host
To exit this mode and prevent the transmission of stored (Batch) data to the host, press the <FUNC> key then the <BK> key. After the stored data is transmitted to the host, the following screen appears: Finished. Clear Data <Enter>=Yes <BK>=No
Press the <ENTER> key to clear the transmitted records/data from the scanner’s memory. Press the <BK> key to retain records/data in the scanner’s memory. If you press the <BK> key, any subsequent scanned bar codes are appended to the end of the existing data.
Daisy-Chaining Cradles Up to 12 cradles can be connected in series (daisy-chained) to communicate through a single serial port. This out-of-the-box capability is a standard feature of the Phaser memory scanner’s default Batch/Inventory application. To enable it, simply daisy-chain the cradles together through COM2. See Setting Up the Cradle on page 2-4 for more details. Each cradle still requires its own power supply.
3-6
Page 39
Operation
Optional - To establish which scanner the data originated from, and to prevent a buffer over-write, the scanner ID of daisy-chained scanners must be changed from the factory default of 001 to a unique number. For information on how to set the scanner ID/scanner address, see Scanner Address on page 5-98. If a scanner is placed in a daisy-chained cradle while another scanner is transferring data to the host, the second scanner will begin its data transfer after the first scanner’s transfer is completed.
Scan and Transmit Application The scan and transmit application allows you to: •
Display and simultaneously transmit data to a host
•
Eliminate repetitive scanning with a quantity entry feature
•
Manually enter alphanumeric data if no bar code is present.
The scanner automatically switches to scan and transmit operation when a cable is attached. The scan and transmit screen appears as follows: SKU: _____________________
In this mode, scanned bar codes are automatically transmitted to the host in real time. Alphanumeric data may be manually entered in the same manner as described in the Batch / Inventory Application on page 3-2. Keyed data transmits once you press the <ENTER> key. To eliminate repetitive scanning, you can enter a quantity prior to scanning a bar code. Refer to Eliminating Repetitive Scanning on page 3-4.
3-7
Page 40
P460/P360 Memory Scanners Product Reference Guide
System Menu The system menu allows the user to set up the operation of the scanner, such as loading a new application, erasing files, setting the scanner ID, etc. Enter System Menu by scanning the bar code below or by entering a keypad sequence. Note: Commonly used System Menu programming bar codes have been consolidated on page 1-4
Enter System Menu Bar Code
To access the System Menu using the keypad sequence, press the <FUNC>, then the <*> key, followed by the <FUNC> key, then the <BK> key. When you enter the system menu, the following screen appears: Phaser Setup 0. System Setup
Below is the list of available options. Press the Up and Down arrow keys to scroll through them. Press <ENTER> to select a menu option. You can also select a menu option by typing the associated menu option number and then pressing <ENTER>. 0. 1. 2. 3. 4. 5. 9.
System Setup App. Control Parameter Control System Status Erase File Version Return to App
The system menu options are described below.
3-8
Page 41
Operation
System Setup System Setup allows you to configure the scanner’s basic settings such as date and time. Option
Description
Sets the communication protocol used by the default 0. Set Com Protocol applications. The options are MCL-Net or RS-232/Synapse. If 0. Scan & Transmit RS-232/Synapse is selected, the scanner automatically -MCL NET identifies whether an RS-232 or Synapse interface is required. -RS232/Synapse -Back to Com Protocol The communication protocol can be set independently for the Scan & Transmit and Batch/Inventory applications. For example, 1. Batch/Inventory you can set the Scan & Transmit application to RS-232 and the -MCL NET Batch/Inventory to MCL NET. -RS232/Synapse -Back to Com Protocol To cancel the change, press the <FUNC> then <BK> keys, or to accept the change, press the <ENTER> key. 9. Back to Main 1. Set Date
Sets the date of the internal clock of the scanner. The scanner displays its current date and provides a prompt for the user to enter the new date. The date format is mm/dd/yyyy. To cancel the change, press the <FUNC> then <BK> keys, or to accept the change, press the <ENTER> key.
2. Set Time
Sets the time of the internal clock of the scanner. The scanner displays its current time value, and provides a prompt for the user to enter the new time. The time format is HH:MM:SS entered in military time. For example, to enter 11:25PM, enter 23:25:00. To cancel the change, press the <FUNC> then <BK> keys, or to accept the change, press the <ENTER> key.
3. Set Contrast
Sets the display contrast. The scanner displays the current contrast setting. Use the up and down arrow keys to change the contrast. The default contrast is 7, and the range is from 0 to 15, with 0 being the lightest and 15 being the darkest. To cancel the change, press the <FUNC> then <BK> keys, or to accept the change, press the <ENTER> key.
4. Set Scanner ID
Sets the scanner ID. The scanner displays its current ID, and the user may key in a new value between 1 and 254. The default is 001. To cancel the change, press the <FUNC> then <BK> keys, or to accept the change, press the <ENTER> key.
9. Back to Main
Returns the user to the system menu.
3-9
Page 42
P460/P360 Memory Scanners Product Reference Guide
Note: The scanner contains a backup power source to retain the time and date information for up to 24 hours after loss of battery power. If battery power is not restored within 24 hours, time and date information will be lost.
3-10