Page 21

Chapter 2 Set Up Introduction This chapter covers the procedures for setting up the Phaser and its accessories.

Unpacking Remove the scanner from its packing and inspect it for damage. If the scanner was damaged in transit, call one of the telephone numbers listed in the section Symbol Support Center on page xi. KEEP THE PACKING. It is the approved shipping container and should be used if you ever need to return your equipment for servicing.

2-1

Page 22

P460/P360 Memory Scanners Product Reference Guide

Cables Connecting the Cable to the Scanner 1. Power down all devices that will be connected to the scanner. 2. Plug the modular connector on the cable into the receptacle in the bottom of the Phaser handle.

The twist-lock can be slipped down the cable to facilitate connecting.

Power Supply Lead Cable Connector on Host Side

Figure 2-1. Connecting the Cable to the Phaser

2-2

Page 23

Set Up

3. Turn the cable twist-lock 1/8 turn clockwise to seat it.

locked position

Figure 2-2. Locking the Cable to the Phaser 4. Gently pull the cable to make certain it is properly seated.

Disconnecting Cables from the Scanner To disconnect the scanner cable: 1. Power down all the devices connected to the scanner. 2. Remove the cable by twisting the twist-lock 1/8 turn counter-clockwise and pulling the cable out.

2-3

Page 24

P460/P360 Memory Scanners Product Reference Guide

Setting Up the Cradle On the bottom of the cradle are three ports. COM1 connects to the host computer, COM2 is used for daisy-chaining multiple base stations together, and the Power port supplies power to the cradle. Connect to host COM1

Power port

COM2 Daisy Chaining

Figure 2-3. Ports on the Cradle 1. Connect an appropriate power supply to the Power port on the cradle. The indicator light on the cradle blinks, signifying successful power-up.

Figure 2-4. Power Supply Port 2. Insert the cable from the host computer into COM1. If daisy chaining multiple cradles, connect the daisy chaining cable to COM2. For additional information on daisy chaining, see Daisy-Chaining Cradles on page 3-6.

Scanner Power Options Two power options are available: •

Battery

•

Power Supply (“Charging”) Cable

2-4

Page 25

Set Up

Charging the Battery Before its first use, the scanner battery may need to be charged. It can be charged: •

Using the cradle

•

Using a cable

•

Using the UBC 2000. Note: For a battery already in use, when the battery’s charge is almost depleted, the scanner emits 4 high tone beeps, when the trigger is pulled, indicating that it must be recharged.

Charging Using the Cradle 1. Connect the power supply to the power input jack on the cradle. 2. Connect the power supply to a receptacle supplying AC power of the proper voltage level. 3. Insert the scanner into the cradle so that the nose of the scanner and tip of the handle seat into the receptacles. The scanner displays “UNIT CRADLED” when properly inserted in the cradle.

Charge Status Indicator Light

Figure 2-5. Placing the Scanner into the Cradle 4. Check the charge status indicator light. For additional information on charging, see Table on page 2-6. 5. The battery charges automatically. A full charge of a depleted battery takes approximately 3-1/2 hours. 2-5

Page 26

P460/P360 Memory Scanners Product Reference Guide

The cradle recharges batteries in the scanner only when the scanner is in the cradle. A scanner with a depleted battery starts charging immediately upon insertion into the cradle, whereas a scanner with a partially charged battery begins charging after approximately 15 minutes. Note that the scanner can be removed from the cradle at any time.

Charging Using a Cable 1. Connect the cable to the scanner. 2. Connect the power supply to the power jack on the cable. 3. Connect the power supply to a receptacle supplying AC power of the proper voltage level. 4. The battery charges automatically. A full charge of a depleted battery takes approximately 3-1/2 hours.

Charging Using the UBC 2000 The battery can be charged using the Universal Battery Charger UBC 2000. The UBC adapter for the P460/P360/P470/P370 scanner battery is required. Refer to the UBC 2000 guide for information on recharging the battery using the UBC 2000.

Charge Status LED Indications The LED indicator on the cradle uses flashing patterns to display the charger status, as shown in the table below. Table 2-1. Cradle LED Indications LED

2-6

Status

Off

The scanner is not in the cradle or has not been properly inserted into the cradle.

Blinking Slowly

The scanner is properly seated in the cradle and charging will begin shortly.

Blinking Rapidly

The battery is actively charging.

On

Battery charging is complete.

Page 27

Set Up

Changing the Battery Once a battery is fully charged, it will generally last up to 12 hours without being returned to the cradle. By returning it to the cradle during the day, you extend this time. If a significant decrease in battery life is noticed and does not correspond to increased usage, consider replacing the battery.

Removing the Battery 1. Slide the release latch down using center indent and remove the cover.

Battery Compartment Cover Battery Release Latch

Figure 2-6. Removing the Battery Compartment Cover 2. Slide the battery toward the bottom of the scanner and then pull the bottom of the battery back and out of the scanner.

Figure 2-7. Pulling the Battery Out

2-7

Page 28

P460/P360 Memory Scanners Product Reference Guide

Inserting the Battery 1. Place the top portion of the battery (curved side up, contacts toward top) into the scanner and then slide it up the handle. 2. Replace the battery compartment cover. 3. Slide the release latch up to secure the cover in place.

Connecting to a Host When Using the Scanner as a Batch Device When using the scanner as a batch device (uncorded) running off its battery, you can transmit stored data to a host in one of two ways: • through a cable connected directly to the scanner

• through a cradle.

When Using the Scanner as a Corded Device When using the scanner as a corded device, power and host communications take place using a cable.

RS-232 Communication with a Host 1. Make sure all host devices are powered down. 2. Plug the communication cable’s connector into an appropriate RS-232 (serial) port on the host device. 3. If using a cradle for communication, plug the power supply lead into the Power port on the bottom of the cradle. If using a cable directly connected to the scanner, plug the power supply lead into the power port on the cable’s connector (see Figure 2-1 on page 2-2). 4. Connect the power supply into an AC receptacle.

2-8

Page 29

Set Up

Using A Synapse Cable with the cradle 1. Make sure all host devices are powered down.

IMPORTANT Before power is provided to the cradle (step 6), the following steps must be completed. The Synapse cable must be connected to the cradle (step 2) AND the flying power lead plugged in (step 4). If the cables are not connected in this sequence, the Synapse Interface Adapter will not operate properly. 2. Connect the Synapse cable to the cradle COM1 port (see Figure 2-3 on page 2-4). 3. Connect the other end of the Synapse cable to the Synapse Interface adapter. 4. The Synapse cable has a flying power lead. Connect this lead to the receptacle in the Synapse Interface adapter, as shown in Figure 2-8. See the Synapse guide for details. To Host

Synapse Interface Adapter (Module)

Synapse Cable Flying Power Lead

To Cradle

Figure 2-8. Synapse and Adapter Cable 5. Connect the Synapse Interface adapter to the host. 6. Connect the power supply to the cradle (see Figure 2-3 and Figure 2-4). 7. Connect the appropriate line cord to the power supply and into an AC receptacle. 8. The indicator light on the cradle blinks, signifying successful power-up. 9. Scan the appropriate Synapse bar codes to set up the Synapse cable for your specifications. 2-9

Page 30

P460/P360 Memory Scanners Product Reference Guide

Using A Synapse Cable with the Scanner 1. Make sure all host devices are powered down.

IMPORTANT Before power is provided to the scanner (step 6), the following steps must be completed. The Synapse cable must be connected to the scanner (step 2) AND the flying power lead plugged in (step 4). If the cables are not connected in this sequence, the Synapse Interface Adapter will not operate properly. 2. Connect the Synapse cable into the bottom of the scanner. 3. Connect the other end of the Synapse cable to the Synapse Interface adapter. 4. The Synapse cable has a flying power lead. Connect this lead to the receptacle in the Synapse Interface adapter, as shown in Figure 2-9. See the Synapse guide for details. To Host Synapse Interface Adapter (Module)

Synapse Cable Flying Power Lead

Power Supply Lead

Power Receptacle

To Cradle

Figure 2-9. Synapse and Adapter Cable 5. Connect the Synapse Interface adapter to the host. 6. Connect the standard Phaser memory scanner power supply to the power receptacle in the Synapse cable. 7. Connect the appropriate line cord to the power supply and into an AC receptacle. 8. Scan the appropriate Synapse bar codes to set up the Synapse cable for your specifications. 2-10

Page 31

Set Up

Wand Emulation, OCIA, OCR, Keyboard Wedges See the instructions packed with the appropriate Synapse cable. An adapter cable is required. See Figure 2-8 on page 2-9.

2-11

Page 32

P460/P360 Memory Scanners Product Reference Guide

2-12