Page 71

Chapter 5 Parameter Menus Introduction This chapter has the optional parameter bar codes necessary to program the Phaser memory scanner.

Operational Parameters The Phaser memory scanner is shipped with the settings shown in Table 5-1. These default values are stored in non-volatile memory and are preserved even when the scanner is powered down. You can change these default values by scanning the appropriate bar codes included in this manual. These new values replace the standard default values in memory. The default parameter values can be recalled by scanning the bar code in the section Set Default Parameter on page 5-7. The scanner automatically detects which cable it is attached to, either an RS-232 or a Synapse cable. If it is attached to an RS-232 cable and has either an ICL, Nixdorf, or Fujitsu host interface, then scan the appropriate bar code from page 5-11 after power up. Any other host interface works with the default setting. If it is attached to a Synapse cable, plug everything together as described on page 2-8 and then follow the directions that come with the Synapse cable for setting up the host interface.

5-1

Page 72

P460/P360 Memory Scanners Product Reference Guide

The following table lists the defaults for all parameters. If you wish to change any option, scan the appropriate bar code(s). Table 5-1. Default Table Parameter

1D P460/P360 Defaults

Page #

All Defaults

5-7

Scan & Transmit Application

RS-232/Synapse

5-8

Batch/Inventory Application

RS-232/Synapse

5-9

RS-232 Host Type

Standard

5-10

Sleep Time

10 seconds

5-13

Forward Slash (/)

5-14

12 Hour

5-15

Decimal Separator

Decimal Point (.)

5-16

Date Format

MM/DD/YYYY

5-17

Key Click

Enable

5-18

Laser On Time

3.0 seconds

5-19

Host Override

Disable

5-20

Beeper Tone

High Frequency

5-21

Beeper Volume

High

5-22

Power Detect Beep

Enable

5-23

Beep After Good Decode

Enable

5-24

Disable

5-25

Set Default Parameter Communication Protocol

Date Separator Hour Type

Beeper Options

Decode Options Transmit “No Read” Message

5-2

Page 73

Parameter Menus

Table 5-1. Default Table (Continued) Parameter

1D P460/P360 Defaults

Page #

UPC-E

Enable

5-26

UPC-A

Enable

5-27

UPC-E1

Disable

5-28

EAN-8

Enable

5-29

EAN-13

Enable

5-30

Bookland EAN

Disable

5-31

Decode UPC/EAN Supplementals

Ignore

5-32

7

5-33

Transmit UPC-A Check Digit

Enable

5-34

Transmit UPC-E Check Digit

Enable

5-34

Transmit UPC-E1 Check Digit

Enable

5-34

UPC-A Preamble

System Character

5-35

UPC-E Preamble

System Character

5-36

UPC-E1 Preamble

System Character

5-37

Convert UPC-E to A

Disable

5-38

Convert UPC-E1 to A

Disable

5-39

EAN-8 Zero Extend

Disable

5-40

UPC/EAN Coupon Code

Disable

5-41

Enable

5-42

UPC/EAN

Decode UPC/EAN Supplemental Redundancy

Code 128 Code 128

5-3

Page 74

P460/P360 Memory Scanners Product Reference Guide

Table 5-1. Default Table (Continued) Parameter

1D P460/P360 Defaults

Page #

UCC/EAN-128

Enable

5-43

ISBT-128

Enable

5-45

Code 39

Enable

5-46

Trioptic Code 39

Disable

5-47

Set Length(s) for Code 39

2 to 55

5-49

Code 39 Check Digit Verification

Disable

5-50

Transmit Code 39 Check Digit

Disable

5-51

Code 39 Full ASCII Conversion

Disable

5-52

Convert Code 39 to Code 32

Disable

5-53

Code 32 Prefix

Disable

5-54

Code 93

Disable

5-55

Set Length(s) for Code 93

4-55

5-56

Enable

5-58

14

5-59

I 2 of 5 Check Digit Verification

Disable

5-61

Transmit I 2 of 5 Check Digit

Disable

5-62

Convert I 2 of 5 to EAN 13

Disable

5-63

Code 39

Code 93

Interleaved 2 of 5 Interleaved 2 of 5 Set Length(s) for I 2 of 5

Discrete 2 of 5

5-4

Page 75

Parameter Menus

Table 5-1. Default Table (Continued) Parameter

1D P460/P360 Defaults

Page #

Disable

5-64

12

5-65

Codabar

Disable

5-67

Set Lengths for Codabar

5-55

5-69

CLSI Editing

Disable

5-70

NOTIS Editing

Disable

5-71

Disable

5-72

Any Length

5-74

One

5-75

Transmit MSI Plessey Check Digit

Disable

5-76

MSI Plessey Check Digit Algorithm

Mod 10/Mod 10

5-77

1

5-78

Bi-directional Redundancy

Disable

5-80

UPC/EAN Security Levels

0

5-81

Discrete 2 of 5 Set Length(s) for D 2 of 5 Codabar

MSI Plessey MSI Plessey Set Length(s) for MSI Plessey MSI Plessey Check Digits

Security Options Linear Code Type Security Levels

5-5

Page 76

P460/P360 Memory Scanners Product Reference Guide

Table 5-1. Default Table (Continued) Parameter

1D P460/P360 Defaults

Page #

Standard

5-10

Baud Rate

9600

5-84

Parity

None

5-85

Check Receive Errors

Disable

5-86

Hardware Handshaking

None

5-87

Software Handshaking

None

5-89

Host Serial Response Time-out

2 Sec.

5-92

RTS Line State (cable use only)

Low

5-92

Stop Bit Select

1

5-93

ASCII Format

8-Bit

5-93

Beep on <BEL>

Disable

5-94

0

5-94

MCL-Net Baud Rate

38400

5-95

MCL-Net Hex Addressing Mode

Disable

5-97

Scanner Address

001

5-98

MCL-Net Transmit Retries

3

5-98

MCL-Net Frame Timeout

500 ms

5-98

RS-232 RS-232 Host Type

Intercharacter Delay MCL-Net

5-6

Page 77

Parameter Menus

Set Default Parameter Scanning this bar code returns all parameters to the values listed in Table 5-1 (factory settings), but does not erase any programmed ADF rules.

SET ALL DEFAULTS

5-7

Page 78

P460/P360 Memory Scanners Product Reference Guide

Communication Protocol The bar codes below set the communication protocol used by the default applications. •

Scan & Transmit application for corded operation

•

Batch/Inventory application for uncorded (Batch) operation.

The communication options are RS-232/Synapse or MCL-Net. If you select RS-232/ Synapse, the scanner automatically identifies whether an RS-232 or Synapse interface is required. MCL-Net allows the scanner to communicate with a host running MCL-Link or MCL-Link Lite. The communication protocols for the two default applications can be set independently of each other. Note: These communication protocol parameters are only for the Scan & Transmit and Batch/Inventory applications and will not work with applications created with MCL-Designer.

Scan & Transmit Application This communication protocol is used for the real time scanning and transmission of data to a host when a cable is attached.

*RS-232/SYNAPSE (Scan & Transmit application only)

MCL-NET (Scan & Transmit application only)

5-8

Page 79

Parameter Menus

Batch/Inventory Application This communication protocol is used when you are ready to transmit your batch records (data collected when the scanner was used without a cable attached) to a host.

*RS-232/SYNAPSE (Batch/Inventory application only)

MCL-NET (Batch/Inventory application only)

5-9

Page 80

P460/P360 Memory Scanners Product Reference Guide

Host Type RS-232 Host Types Most RS-232 hosts work fine with the default settings, however, three RS-232 hosts are set up with their own parameter default settings. Selecting the ICL, Fujitsu or Nixdorf RS-232 host interface sets the defaults listed below. These defaults take precedence over Standard RS-232 defaults. So, if you select the Fujitsu RS-232 first, and then select the Standard RS-232 defaults, the Fujitsu defaults still take precedence. To return to the factory set defaults, scan the SET ALL DEFAULTS bar code on page 5-7. Table 5-2. Terminal Specific RS-232 Parameter

Standard

ICL

FUJITSU

NIXDORF Mode A/ Mode B

Transmit Code ID

No

Yes

Yes

Yes

Data Transmission Format

Data as is

Data/Suffix

Data/Suffix

Data/Suffix

Suffix

CR/LF

CR

CR

CR

Baud Rate

9600

9600

9600

9600

Parity

None

Even

None

Odd

Hardware Handshaking

None

RTS/CTS Option 3

None

RTS/CTS Option 3

Software Handshaking

None

None

None

None

Serial Response Time-out

2 Sec.

9.9 Sec.

2 Sec.

9.9 Sec.

Stop Bit Select

One

One

One

One

ASCII Format

8-Bit

8-Bit

8-Bit

8-Bit

Beep On <BEL>

Disabled

Disabled

Disabled

Disabled

RTS Line State

Low

High

Low

*Low = No data to send

*In the Nixdorf Mode B, if CTS is Low, transmission of scan data is disabled. When CTS is High, bar code data is transmitted to the host. **If Nixdorf Mode B is scanned without the scanner connected to the proper host, it may appear unable to scan. If this happens, scan a different RS-232 host type within 5 seconds of cycling power to the scanner.

5-10