Page 81

Parameter Menus

Scan the appropriate bar code below to select an RS-232 Host Interface.

*STANDARD RS-232

ICL RS-232

NIXDORF RS-232 Mode A

NIXDORF RS-232 Mode B

FUJITSU RS-232

OPOS

5-11

Page 82

P460/P360 Memory Scanners Product Reference Guide

Code ID Characters for RS-232 Host Types Selecting the ICL, Fujitsu, or Nixdorf RS-232 host interface enables the transmission of Code ID Characters as listed below. These Code ID Characters are not programmable and are separate from the Transmit Code ID feature. The Transmit Code ID feature should not be enabled for these hosts.

Table 5-3. Terminal Specific Code ID Characters ICL

5-12

FUJITSU

NIXDORF

UPC-A

“A”

“A”

“A”

UPC-E

“E”

“E”

“C0”

EAN-8

“FF”

“FF”

“B”

EAN-13

“F”

“F”

“A”

Code 39

“C” <len>

None

“M”

Codabar

“N” <len>

None

“N”

Code 128

“L” <len>

None

“K”

I 2 of 5

“I” <len>

None

“I”

Code 93

None

None

“L”

D 2 of 5

“H” <len>

None

“H”

UCC/EAN 128

“L” <len>

None

“P”

MSI/Plessey

None

None

“O”

Bookland EAN

“F”

“F”

“A”

Unlisted Code Types

None

None

None

Page 83

Parameter Menus

Sleep Time Scan the bar code below to select how long the scanner will “stay awake” (not power down) in seconds after a trigger pull or a key press. First scan this bar code, then enter a range from 05 to 32, using the Numeric Bar Codes on page 5-99. It can stay awake from 5 seconds to 32 seconds. The default time is set at 10 seconds. Note: Allowing the scanner to stay awake longer than originally programmed may effect the battery life time for that session before needing a charge.

SLEEP TIME (RANGE OF 5 TO 32 SECONDS)

5-13

Page 84

P460/P360 Memory Scanners Product Reference Guide

Date Separator Scan the appropriate bar code below to select which separator to use when displaying the date. Choose FORWARD SLASH, DASH, COLON or NONE.

*FORWARD SLASH (/)

DASH (-)

COLON (:)

NONE

5-14

Page 85

Parameter Menus

Hour Type Scan the appropriate bar code below to select how to display the hour and transmit it to the host device. Choose 12 HOUR (6:00 pm) or 24 HOUR (18:00).

24 HOUR

*12 HOUR

5-15

Page 86

P460/P360 Memory Scanners Product Reference Guide

Decimal Separator Scan the appropriate bar code below to select what separator to display when you hit the decimal point key on the keypad. Choose DECIMAL POINT (.) or COMMA (,).

*DECIMAL POINT (.)

COMMA (,)

5-16

Page 87

Parameter Menus

Date Format Scan the appropriate bar code below to select how to format the date when it is displayed and transmitted to the host device. Choose MM/DD/YYYY or DD/MM/YYYY.

*MM/DD/YYYY

DD/MM/YYYY

5-17

Page 88

P460/P360 Memory Scanners Product Reference Guide

Key Click Scan the appropriate bar code below to select whether the keypad click is enabled or not. Choose ENABLE or DISABLE.

*ENABLE

DISABLE

5-18

Page 89

Parameter Menus

Laser On Time This parameter sets the maximum time decode processing continues during a scan attempt. It is programmable in 0.1 second increments from 0.5 to 9.9 seconds. Scan the bar code below to set a Laser On Time. Next scan two numeric bar codes beginning on page 5-99 that correspond to the desired time. Time less than 1.0 second must have a leading zero. For example, to set a Time On of 0.5 seconds, scan the bar code below, then scan the “0” and “5” bar codes. If you make an error, or wish to change your selection, scan CANCEL on page 5-101. The default time is set at 3 seconds.

LASER ON TIME

5-19

Page 90

P460/P360 Memory Scanners Product Reference Guide

Host Override This parameter allows the scanner to communicate when it is not on any auxiliary power supply. When this parameter is enabled, the scanner does not wait for cradle or cable connection, but just begins transmitting.

ENABLE

*DISABLE

5-20