Page 45
Operation
123Scan 123Scan is an intuitive Windows based utility that allows you to customize your scanner setup and generate Advanced Data Formatting (ADF) rules. An Advanced Data Formatting rule gives you the ability to modify the bar code data before sending it to the host such as appending a carriage return, or some other prefix/suffix value, to the bar code data. This enhances capability between bar code data and your host software, allowing you to program the scanner rather than modifying your host application. The scanner can be programmed via a serial (RS-232) download or by scanning 123Scan generated programming bar codes. Scanner programming is saved in a setup file which can be distributed electronically (Web site, floppy disk, or E-mail). A copy of 123Scan is on the CD included with your scanner. It is also available on the Symbol Web site http://www.symbol.com. Use the web site’s search tool to find “123Scan” and select the P460/360 product line. Note: Advanced data formatting rules created with 123Scan are for use with the default application only and will not work with applications created with MCL-Designer. To download a 123Scan generated ADF rule, scan the bar code below. Place the scanner in its cradle or attach an RS-232 cable. Then initiate the download on the PC utility.
Load 123Scan File
To remove previously programmed ADF rules from the scanner, scan the bar code below.
Reset Default Application (Clears previously programmed ADF rules)
3-17
Page 46
P460/P360 Memory Scanners Product Reference Guide
Suffix Values 123Scan generated programming bar codes for two commonly used suffixes (Enter and Tab) have been included in this Product Reference Guide. To append an Enter key* to the transmitted bar code data, scan all nine (9) ADF rule bar codes and then the Reset Scanner bar code, in that order.
* ASCII value 7013 ADF Rules 1/9
2/9
3/9
4/9
3-18
Page 47
Operation
5/9
6/9
7/9
8/9
9/9
RESET SCANNER
3-19
Page 48
P460/P360 Memory Scanners Product Reference Guide
To append a Tab * to the transmitted bar code data, scan all nine (9) ADF rule bar codes and then the Reset Scanner bar code, in that order.
* ASCII value 7009 ADF Rules 1/9
2/9
3/9
4/9
3-20
Page 49
Operation
5/9
6/9
7/9
8/9
9/9
RESET SCANNER
3-21
Page 50
P460/P360 Memory Scanners Product Reference Guide
Scanning The scanner ships with the default application and default parameters that is ready-to-use right out of the box. If this is not what you need for your application, refer to the MCL Designer Manual for programming instructions and Chapter 5, Parameter Menus for scanning and communications parameters. If you need assistance, contact your local supplier or Symbol Support Center. 1. If you are using the scanner in corded mode, make sure all cable connections are secure. Otherwise, make sure the battery is sufficiently charged. 2. Make sure the bar code is in the correct scanning range. Aim and press the trigger. The scanner has read the symbol when: •
You hear a beep.
•
The LED above the screen turns green.
•
The red laser turns off.
Figure 3-1. Scanning a Bar Code
Scan the Entire Symbol •
Your scan beam must cross every bar and space on the symbol.
•
The larger the symbol, the farther away you should hold the scanner.
•
Hold the scanner closer for symbols with bars that are close together.
•
A short, high tone beep indicates a good decode.
3-22
Page 51
Operation
Right
Wrong
Hold at an Angle Do not hold the scanner directly over the bar code. Laser light reflecting directly back into the scanner from the bar code is known as specular reflection. This strong light can “blind” the scanner and make decoding difficult. The area where specular reflection occurs is known as a “dead zone.” You can tilt the scanner up to 65° forward or back and still achieve a successful decode. Simple practice quickly shows what tolerances to work within.
65
65
Shaded area represents _2 ) dead zone (+ Scan Beam
Scan Beam
Bar Code
Bar Code
Bar Code
Figure 3-2. Maximum Tilt Angles and Dead Zone
3-23
Page 52
P460/P360 Memory Scanners Product Reference Guide
Test Symbols To ensure your scanner is working properly, try scanning the following bar codes. If you have trouble, refer to Troubleshooting on page 3-29.
CODE 128
UPC
3-24