Page 53

Operation

Decode Zone

15.6 in. 39.6 cm 10 in. 25.4 cm 5 in. 12.7 cm 0 in. 0 cm 5 in. 12.7 cm

5 mil

Width

Of Field

10 in. 25.4 cm

7.5 mil 10 mil

15.6 in. 39.6 cm

100% UPC 15 mil 20 mil 40 mil 55 mil

0 in. 0 cm

5 in. 12.7 cm

10 in. 25.4 cm

15 in. 38.1 cm

20 in. 50.8 cm

25 in. 63.5 cm

30 in. 76.2 cm

35 in. 88.9 cm

40 in. 101.6 cm

45 in. 114.3 cm

Distance From Front Of Scanner

Figure 3-3. P460/P360 Scanner - Decode Zone

3-25

Page 54

P460/P360 Memory Scanners Product Reference Guide

Keypad Operation Instead of scanning a bar code, you can enter the bar code data using the keypad on the top of the scanner. By default, this feature is enabled. To disable alphanumeric data entry via the keypad, go to the symbologies tab inside 123Scan and remove the “X” from the check box next to “Keypad”. (This does not disable the quantity entry feature discussed in Eliminating Repetitive Scanning on page 3-4.) For additional information on 123Scan, see 123Scan on page 3-17. To enter numeric data, type the numeric value desired and press <ENTER>. A beep lets you know that the entry was accepted. See Figure 3-4 on page 3-28. To enter alpha characters, press the <Mode> key once to put the scanner in Alpha Mode. Numeric buttons 1 through 9 are associated with the alpha characters. For example, the letters A, B and C are located on numeric button 7. Press the button with the letter you desire - once for the letter A, twice for the letter B, or three times for the letter C. You can continue entering alpha characters or switch to numerics. Press <ENTER> to save or send the data. To return to numeric entry mode after entering alpha characters, press the <Mode> key again. For example, to manually enter 17ABF5, do the following steps: Data

Action

1

Press numeric button 1.

7

Press numeric button 7.

A

Press <MODE> button once, then numeric button 7 once. Wait for one second (you will hear a low pitched beep).

B

Press numeric button 7 twice.

F

Press numeric button 8 three times.

5

Press <MODE> button once, then numeric button 5 once, then <ENTER>.

Every time you press the button with the letter you desire, you hear a low-pitched beep to let you know that the entry was registered. Although the entry is registered, it has not been

3-26

Page 55

Operation transferred to the host yet. A high-pitched beep lets you know that the entry has been transferred to the host. To return to numeric mode, press the Mode key again. Pressing the Enter key saves the data. To put a decimal point (.) into numeric data, type in the numbers before the decimal point, then press the mode key, press the decimal, and press the mode key again. Now resume typing in the values to the right of the decimal. To enter a dash (-), press the mode key once, then the zero (0) key twice. To enter a blank space ( ), press the mode key once, then the zero (0) key three times. The Function key in combination with a numeric key can be programmed to launch an operation, such as allowing you to review records. To use the Function key to review records, press the <FUNC> key, release it, and then press the <2> key. For more

3-27

Page 56

P460/P360 Memory Scanners Product Reference Guide information on how to program these keys for additional tasks and operations, refer to the MCL Designer User’s Guide p/n 70-37689-XX.

Figure 3-4. Scanner Keypad

3-28

Page 57

Operation

Troubleshooting Refer to Appendix B, Messages and Error Codes for additional troubleshooting information. Table 3-1. Troubleshooting Tabl e Problem

Solution

General problem solving • Check that the power supply is attached to the cradle or to the cable. • Check for loose cable connections at the scanner, cradle, AC power supply, or host device. • Check the scanner’s battery charge level. See Battery Check on page 3-14. • Make sure the device is programmed to read the type of bar code you want to scan. • Check the symbol to make sure it is not defaced. • Try scanning another similar symbol of the same code type. • Be sure you are within the proper scanning decode range. • Reboot (reset) the scanner (hold down the ENTER key for about 30 seconds) and try scanning again. The scanner emits error beeps after decoding a bar code.

• Check that the scanner is powered up and that its cable connections are secure. • Be sure the cable connection to the host is secure. • Check that the appropriate host type is selected.

3-29

Page 58

P460/P360 Memory Scanners Product Reference Guide

Table 3-1. Troubleshooting Table (Continued) Problem

Solution

The scanner does not scan the programming bar codes in this PRG.

• For MCL-Designer generated applications, put the scanner into “Scan Parameter” mode in the system menu (see Scan Parameters on page 3-14). • For the default application running on a previous version of the following firmware: P460/P360

1 MB

Revision N or lower, such as M

P460/P360

4 MB or 8 MB

Revision H or lower, such as G put the scanner into “Scan Parameter” mode in the system menu (see Scan Parameters on page 3-14). For instructions on how to check the scanner’s firmware version, see Version on page 3-16. The PC cannot download • Check to make sure you are using an RS-232 cable. The an application to the application can not be downloaded to a scanner using a scanner. Synapse cable.

• Check to make sure the power supply is connected to the cradle or scanner. The Scanner will not load • Software download to the scanner while the scanner is my ADF rule. running the default application.

•

Check that the cradle and PC are connected using an RS-232 cable.

• Software download or scanning a bar code sheet while the scanner is running an MCL-Designer generated application

3-30

•

Erase the MCL-Designer application from the scanner’s memory by scanning the “Reset Default Application” bar code on page 3-12.

•

The default application is now reinstalled and an ADF rule can be loaded.

Page 59

Operation

Note: If after performing these checks the symbol still does not scan, contact your distributor or call the Symbol Support Center. See Symbol Support Center on page page xi for the telephone number.

3-31

Page 60

P460/P360 Memory Scanners Product Reference Guide

3-32