The text of a manual · part 7 of 22
P460/P360 Memory Scanners Product Reference Guide: Chapter 3 Operation, pages 37 to 44
Pages 37 to 44 of 188, from P460/P360 Memory Scanners Product Reference Guide
The original document is the PDF (1.9 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Symbol P360 and Symbol P460
Page 37
Operation
System Setup System Setup allows you to configure the scanner’s basic settings such as date and time. Option
Description
0. Set Com Protocol Sets the communication protocol used by the default 0. Scan & Transmit applications. The options are MCL-Net or RS-232/Synapse. If RS-232/Synapse is selected, the scanner automatically -MCL NET identifies whether an RS-232 or Synapse interface is required. -RS232/Synapse -Back to Com Protocol The communication protocol can be set independently for the Scan & Transmit and Batch/Inventory applications. For example, 1. Batch/Inventory you can set the Scan & Transmit application to RS-232 and the -MCL NET Batch/Inventory to MCL NET. -RS232/Synapse -Back to Com Protocol To cancel the change, press the <FUNC> then <BK> keys, or to accept the change, press the <ENTER> key. 9. Back to Main 1. Set Date
Sets the date of the internal clock of the scanner. The scanner displays its current date and provides a prompt for the user to enter the new date. The date format is mm/dd/yyyy. To cancel the change, press the <FUNC> then <BK> keys, or to accept the change, press the <ENTER> key.
2. Set Time
Sets the time of the internal clock of the scanner. The scanner displays its current time value, and provides a prompt for the user to enter the new time. The time format is HH:MM:SS entered in military time. For example, to enter 11:25PM, enter 23:25:00. To cancel the change, press the <FUNC> then <BK> keys, or to accept the change, press the <ENTER> key.
3. Set Contrast
Sets the display contrast. The scanner displays the current contrast setting. Use the up and down arrow keys to change the contrast. The default contrast is 7, and the range is from 0 to 15, with 0 being the lightest and 15 being the darkest. To cancel the change, press the <FUNC> then <BK> keys, or to accept the change, press the <ENTER> key.
4. Set Scanner ID
Sets the scanner ID. The scanner displays its current ID, and the user may key in a new value between 1 and 254. The default is 001. To cancel the change, press the <FUNC> then <BK> keys, or to accept the change, press the <ENTER> key.
9. Back to Main
Returns the user to the system menu.
3-9
Page 38
P460/P360 Memory Scanners Product Reference Guide
Note: The scanner contains a backup power source to retain the time and date information for up to 24 hours after loss of battery power. If battery power is not restored within 24 hours, time and date information will be lost.
3-10
Page 39
Operation
App. Control App. Control allows you to control your application, specifically, load new system application files on your scanner, reset your default applications, etc. You can load a new application/file or system code by either scanning the appropriate bar code or entering the appropriate keypad value as indicated on the display.
Option 0. Load App / File
Description Puts the scanner into a mode to receive MCL-Designer application downloads, file updates, and MCL-Link commands from the host. To enter this mode using the key pad, select this option on the system menu. The following screen displays: Load New App/File <Enter>=Yes <BK>=No OR To enter this mode from an application without entering the system menu, scan the bar code below.
Load New Application/File
Status: Connect unit to host When this screen displays, the scanner is ready to accept the download. On the PC Utility, initiate the download. After downloading is complete, the system menu is exited and the application initiated. To exit this mode and prevent the download of a new application, press the <FUNC> then <BK> keys.
3-11
Page 40
P460/P360 Memory Scanners Product Reference Guide
Option 1. Set Default App
Description Reinstalls the default application and returns all parameters to their factory settings (values listed in Table 5-1). The default application overwrites any MCL-Designer application and/or ADF rules. This option may be used to restore functionality to a scanner which has been loaded with a defective application. To enter this mode using the key pad, select this option on the system menu. Prior to resetting the default application, the user is prompted to confirm this operation: Reset Default App? <Enter>=Yes <BK>=No
Press the <ENTER> key to confirm the choice (Yes) or the <BK> key to cancel the choice (No). If you entered “Set Default App” from the System Menu, upon resetting the default application, you will return to the System Menu. OR To enter this mode from an application without entering the system menu, scan the bar code below.
Reset Default Application (Clears previously programmed ADF rules and/or MCL-Designer applications) If you entered the “Set Default App” mode using the bar code above, the default application will automatically be reset, the System Menu exited, and the application re-initiated.
3-12
Page 41
Operation
Option 2. System Code
Description Updates the scanner operating system (Firmware). An RS-232 cable is required. It connects the scanner (not the cradle) to the host. To enter this mode using the key pad, select this option on the system menu. Load New System Code <Enter>=Yes <BK>=No
Press the <ENTER> key to confirm the choice (Yes) or the <BK> key to cancel the choice (No). OR To enter this mode from an application without entering the system menu, scan the bar code below.
System Code
Attach RS232 Cable and Press ENTER
Attach the RS-232 cable and press <ENTER> to start the download.
Scanner ready, On PC start download
After the download is complete, the system menu is exited and the application initiates. To exit this mode and prevent the download of new firmware, press and hold the <ENTER> key for 30 seconds. 9. Back to Main
Returns the user to the system menu.
3-13
Page 42
P460/P360 Memory Scanners Product Reference Guide
Parameter Control Parameter Control allows you to control the scanner parameters such as Scan Parameters and Set Default Params. Option 0. Scan Parameters
Description This feature only works when used with an application generated with MCL-Designer and allows you to program your scanner by scanning the bar codes in Chapter 5, Parameter Menus. Parameters already set in your MCL-Designer generated application can not be overridden by scanning bar codes. When you see the following screen, you can begin scanning parameter bar codes: Scan Parameters <FUNC> <BK> to quit After scanning the desired bar codes, press <FUNC> then <BK> keys to exit this mode.
1. Set Default Param
Restores the default parameters in the scanner. The default parameters overwrite any scanned parameters. Prior to resetting the default parameters, you are prompted to confirm your choice.
9. Back to Main
Returns the user to the system menu.
System Status System Status allows you to perform system checks such as Battery Check. Option 0. Battery Check
Description Checks the battery charge level. Good indicates the battery does not require recharging. Low/Recharge indicates the scanner requires a recharge. When the battery is close to complete discharge, the following message displays: Recharge Battery
9. Back to Main
3-14
Returns the user to the system menu.
Page 43
Operation
Erase File Erase File
Erase File allows you to erase your scanner batch data. It is recommended that data files be transferred from the scanner to the host before erasing. A screen prompts you to indicate which file is being erased. The batch/Inventory application data is always saved in file A. File to Erase? (A-H)
Enter the file name, (the name is a single letter between A and H), then press <ENTER> to erase the file.
3-15
Page 44
P460/P360 Memory Scanners Product Reference Guide
Version Version
This option displays the version of firmware (operating system) run by the scanner and the size of the scanner’s memory, such as 1024k (1 MB). For example, the firmware version shown on the display below is NBRVSMAP, also called Revision “P” (which is the last letter of the firmware’s full name). To enter this mode using the keypad, select this option on the System Menu. The following screen displays. Scanner: NBRVSMAP MCL: 4.x Mem: 1024
If you entered “Version” from the System Menu, after 15 seconds or by pressing <ENTER>, you will return to the System Menu. OR To enter this mode from an application outside of the System Menu, scan the bar code below.
Scanner Firmware Version If you entered “Version” using the bar code above, after 15 seconds or by pressing <ENTER>, you will automatically exit the System Menu and re-enter the application.
Return to App Return to App.
3-16
Return to App exits the system menu and returns to the application. To do this, press <9> then <ENTER>.