Configuration 3 - 19

Update The fifth branch of the MK1200 Configuration Utility window and System Menu is Update. The default parameters are listed in Table 3-7. Table 3-7 Update Default Parameters

Update Parameters FTP Server

Description

Default

FTP Configuration

Allow Anonymous

Determines whether the server allows anonymous access.

Enabled

Allow Anonymous Upload

Determines whether authorization is required for uploading files to server.

Enabled

FTP Enable Part I

Determines whether the FTP server is loaded/accessible when the kiosk is powered on. Note that disabling this parameter has no impact on the ability to load or retrieve mkconfig.reg files via the Remote Device Manager's Push Configuration File and Retrieve Remote Configuration File functionality.

Enabled

FTP Enable Part II

Enabling this parameter allows the RDM to load/retrieve a mkconfig.reg file even if the kiosk's FTP server is disabled (FTP Enable Part I = disabled). If this parameter and FTP Enable Part I are both disabled, you cannot load an mkconfig.reg file remotely via the Configuration Utility or FTP. You can still load an mkconfig.reg file locally via an ActiveSync connection or a PC card.

Enabled

Root Directory

Directory and subdirectories of this key are accessible remotely. If this value is not set in the registry, the default is \Temp.

\

Use Authentication

Determines whether authorization is required to connect to the server.

Disabled

User Authentication Domain

Domain that holds information on authentic users that are allowed to access FTP service from the server.

None

User List

List of users able to access the FTP server.

None

Page 66

3 - 20 MK1200 MicroKiosk for CE .NET 4.2 Product Reference Guide

Control Panel Configuration Parameters On touch-enabled configurations, when using the Windows® desktop Control Panel to modify certain MK1200 configuration settings, select Start > Programs > Save Configuration on the MK1200 to save certain parameter changes to the mkconfig.reg file and retain them across power cycles. If not saved, the MK1200 defaults to the original mkconfig.reg parameter values upon the next power sequence. The Control Panel can set the following options:

• Backlight and Contrast Settings on page 3-20 • Button Definitions on page 3-21 • Date and Time on page 3-21 • Inactivity Manager on page 3-22 • Gate Keeper (Password Protection) on page 3-23 • Stylus Settings/Touch Screen Calibration on page 3-23 • Regional Settings on page 3-25 • Memory Allocation on page 3-26. For best results, use the system menu for all permanent changes (except recalibrating the touch screen).

Backlight and Contrast Settings To change the backlight intensity on the MK1200: 1.

Tap Start > Settings > Control Panel.

2.

Double-tap the Backlight & Contrast icon from the Control Panel window.

Figure 3-4 Backlight & Contrast Screen 3.

Select the backlight intensity by tapping the radio button.

4.

If necessary, change the contrast by tapping the arrows next to the Contrast field.

5.

Tap OK or X to close the screen to apply the selection.

Page 67

Configuration 3 - 21

Button Definitions To change the button mapping on the MK1200: 1.

Tap Start > Settings > Control Panel.

2.

Double-tap the Button Definitions icon from the Control Panel window.

Figure 3-5 Button Definitions Screen 3.

Tap on the button to remap. The button’s current hex code appears in the text box.

4.

Using the input panel, enter the new value of the hex code in the text box to remap the button. Also use this option to remap button combinations. See Table 7-6 on page 7-9 for correct key codes.

5.

To change the buttondown delay, enter the new value using the input panel.

6.

Tap OK or X to close the screen and apply the selection.

7.

Tap Start > Programs > Save Configuration to save the new settings in the MK1200 configuration (mkconfig.reg) file.

Date and Time To set the date/time on the MK1200: 1.

Tap Start > Settings > Control Panel > Date/Time icon.

2.

Double-tap the Date/Time icon from the Control Panel window. The Date/Time Properties screen appears.

Figure 3-6 Date/Time Properties Screen 3.

To set the month, tap the arrows on either side of the month shown, or select the month label to choose from a list of months.

Page 68

3 - 22 MK1200 MicroKiosk for CE .NET 4.2 Product Reference Guide

4.

To select a date, tap the date in the calendar.

5.

To set the current time, highlight the hours, minutes, seconds, or AM/PM field in the Current Time field. Tap the up/down scroll arrows to change the highlighted selection.

6.

To change the time zone, use RDM.

7.

Tap Apply to apply the new date/time settings.

8.

Tap Start > Programs > Save Configuration to save the new settings in the MK1200 configuration (mkconfig.reg) file. NOTE

The date resets to June 1, 1999, 12:00 PM upon a cold boot. Use the Control Panel or the SNTP Client to update this (see Network Time Update: SNTP Client on page 7-10). To permanently set the time zone and daylight saving settings, use the RDM or System Menu on the MK1200.

Inactivity Manager To set up the inactivity manager: 1.

Tap Start > Settings > Control Panel.

2.

Double-tap the Inactivity Manager icon.

Figure 3-7 Inactivity Manager Screen 3.

Select the application to run during inactivity by tapping the SimpleSaver.exe.)

button. (The default application is

4.

Enter the timeout value (in seconds). The default is 0, which allows the system to run continuously without entering inactivity mode.

5.

Tap OK.

6.

Tap Start > Programs > Save Configuration to save the settings in the MK1200 configuration (mkconfig.reg) file.

Page 69

Configuration 3 - 23

Gate Keeper (Password Protection) To run an application in protected mode: 1.

Tap Start > Settings > Control Panel.

2.

Double-tap the Gate Keeper icon from the Control Panel window. The Gate Keeper screen appears.

Figure 3-8 Gate Keeper Screen 3.

Select the application to run in protected mode by tapping the button. Note: Changing this application is not recommended. Errors in this configuration parameter or the program that is run can prevent troubleshooting or interacting with the MK1200 in protected mode.

4.

Specify the password to access protected mode, and enter it a second time to confirm it.

5.

Tap OK.

6.

Tap Start > Programs > Save Configuration to save the new settings in the MK1200 configuration (mkconfig.reg) file. NOTE

When Button Security is enabled, a password is required to access functionality launched by the physical buttons.

Stylus Settings/Touch Screen Calibration

NOTE

This section applies to touch screen units only.

The double-tap speed and calibration setting are factory-set. To recalibrate the Stylus settings: 1.

Tap Start > Settings > Control Panel > Stylus.

Figure 3-9 Stylus Properties Screen - Double-Tap Tab 2.

On the Double-Tap tab, double-tap the checkerboard grid at a comfortable speed.

Page 70

3 - 24 MK1200 MicroKiosk for CE .NET 4.2 Product Reference Guide

3.

Double-tap the clapboard to test the settings. If the icon does not change, adjust the settings on the checkerboard and test the settings again.

4.

If the MK1200 is not responding properly to taps, tap the Calibration tab to calibrate the screen.

Figure 3-10 Stylus Properties Screen - Calibrate Tab NOTE

5.

Alternatively, to access the Calibrate screen simultaneously press the buttons A, C, and D (see Figure 1-1 on page 1-3).

Tap the Recalibrate button and follow the directions on the screen.

Figure 3-11 Calibrate Screen 6.

The system returns to the Stylus Properties screen when calibration completes. To cancel calibration, press the C and D buttons simultaneously.

7.

Tap OK on the Stylus Properties screen. Note that calibration values are stored separately from other configuration settings in non-volatile storage and cannot be accessed by the user.

Page 71

Configuration 3 - 25

Regional Settings To set up or change regional settings: 1.

Tap Start > Settings > Control Panel > Regional Settings icon.

Figure 3-12 Regional Settings Properties Screen - Regional Settings Tab 2.

On the Regional Settings tab, in Your locale (location), select the region to use for date, time, number, and currency formatting from the drop-down list.

3.

To change the way numbers appear, tap the Number tab and make the changes.

Figure 3-13 Regional Settings Properties Screen - Number Tab 4.

To change the way currency values appear, tap the Currency tab and make the changes.

Figure 3-14 Regional Settings Properties Screen - Currency Tab 5.

To change the way the time appears, tap the Time tab and make the changes.

Figure 3-15 Regional Settings Properties Screen - Time Tab

Page 72

3 - 26 MK1200 MicroKiosk for CE .NET 4.2 Product Reference Guide

6.

To change the way the date appears, tap the Date tab and make the changes.

Figure 3-16 Regional Settings Properties Screen - Date Tab 7.

Tap Start > Programs > Save Configuration to save the new settings in the MK1200 configuration (mkconfig.reg) file.

Memory Allocation To change memory allocation settings: 1.

Tap Start > Settings > Control Panel > System > Memory.

Figure 3-17 System Properties Screen - Memory Tab 2.

On the Memory tab, adjust the memory allocation as desired using the slider.

3.

Tap OK. NOTE

Changing these settings using the Control Panel does not persist them through cold boot cycles. To set allocation to persist through cold boot cycles, or for more information on this topic, see Memory Management on page 7-10.