Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 10 of 29

MK1200 MicroKiosk for CE .NET 4.2 Product Reference Guide: Remote Device Manager, pages 73 to 82

Pages 73 to 82 of 232, from MK1200 MicroKiosk for CE .NET 4.2 Product Reference Guide

The original document is the PDF (5.9 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Symbol MK-1200

Page 73

Chapter 4 Remote Device Manager Introduction The Symbol Remote Device Manager (RDM) 2.5 is a simple, menu-based Windows® utility for streamlining large and small site deployments. This utility allows a user to remotely stage (discover and configure) and monitor networked MK1200s. The RDM functionality falls into five categories:

• Generating a device configuration file • Performing discovery (detection) of devices on a network • Enabling automated staging/configuring/provisioning of networked devices • Remote monitoring • Remotely initiating device functionality.

Generating Configuration Files Use the Create Local Configuration File feature of RDM to create an MK1200 configuration file (mkconfig.reg). When loaded onto the device, this file customizes the MK1200 communication settings, application settings, date and time setup, and much more. After generating the mkconfig.reg file, load it into the MK1200 Application folder (Desktop > My Computer > Application) and reboot the device. The MK1200 reads the mkconfig.reg file upon power-up and configures its parameters according to the settings defined in the mkconfig.reg file. If the MK1200 loses power, the parameters set within the configuration file persist and are re-established at the next power up. See Creating a Configuration File on page 4-11 for more information.

Page 74

4-2

MK1200 MicroKiosk for CE .NET 4.2 Product Reference Guide

Performing Discovery (Detection) of Devices on a Network The RDM discovers and displays the IP addresses of MK1200s on different subnets to which the host computer is connected, provided that the broadcast IP address is set correctly. See Setting RDM Options on page 4-14 for more details. The RDM utility broadcasts a request for discovery, and each MK1200 responds with its IP address. The RDM utility displays all responding MK1200 IP addresses on the main RDM screen. The RDM can remotely initiate actions, such as playing a sound file, on the discovered device to help locate it in a store environment. NOTE

RDM performance and consistency when performing discovery on a network are directly related to network reliability.

Automated Staging/Configuring/Provisioning of Networked Devices The RDM can load a device configuration file (mkconfig.reg) onto an MK1200 remotely. This process is automated and does not require user intervention. For details, see Creating a Configuration File on page 4-11 and Downloading the Configuration File to the MK1200 Using the RDM on page 4-13.

Remote Monitoring Use the RDM to determine device-specific information. After performing discovery, select an MK1200 from the discovery list box to retrieve information to view:

• Device general information • Operating System versions • Storage information • Partition information • Application versions • RF Signal Strength. See Monitoring MK1200s on a Network on page 4-15 for more information.

Remotely Initiating Select Device Functionality Use the RDM to remotely initiate select functionality on MK1200s. After performing discovery, highlight desired devices from the discovery list box to initiate remote functionality on these devices, such as launching AirBeam Smart or rebooting the device.

Page 75

Remote Device Manager

4-3

Installing the Symbol Remote Device Manager The RDM is available for download from the Symbol Developer Zone web site (http://devzone.symbol.com/). 1.

Download the Symbol Remote Device Manager install file and save it on the host computer hard drive.

2.

Select Start > Run from the Windows® task bar.

3.

Using the Browse button, locate the Symbol Remote Device Manager install file and select OK.

4.

The Symbol Remote Device Manager First Install Screen provides copyright information. Select Next to continue.

Figure 4-1 Symbol Remote Device Manager First Install Screen 5.

The Symbol Remote Device Manager Select Installation Folder screen provides the directory information for the installation. Enter a new install path or accept the default path, and select users. Click Next to continue.

Figure 4-2 Symbol Remote Device Manager Select Installation Folder

Page 76

4-4

MK1200 MicroKiosk for CE .NET 4.2 Product Reference Guide

6.

The Symbol Remote Device Manager Confirm Installation screen requests to confirm installation. Click Next to continue.

Figure 4-3 Symbol Remote Device Manager Confirm Installation 7.

The Symbol Remote Device Manager Installation Complete screen confirms the installation was completed successfully. Click Close to exit.

Figure 4-4 Symbol Remote Device Manager Installation Complete

Page 77

Remote Device Manager

4-5

Symbol Remote Device Manager Main Screen To open the Symbol Remote Device Manager on the host computer, select Start > Programs >Symbol Remote Device Manager > Symbol Remote Device Manager.

Figure 4-5 MK1200 Symbol Remote Device Manager

Symbol Remote Device Manager Menus Use the menus on the Symbol Remote Device Manager (RDM) main screen to perform the functions in Table 4-1. Table 4-1 Symbol Remote Device Manager Menu Items

Menu Item

Function

File Menu Exit

Exits the Symbol Remote Device Manager.

Edit Menu Select All

Selects all MK1200s in the list.

Select None

Deselects all MK1200s in the list.

View Menu Refresh (Discover Remote Devices)

Locates all MK1200s on the network and displays them in the list box.

Device Information

Displays information on the selected MK1200. See Monitoring MK1200s on a Network on page 4-15.

Page 78

4-6

MK1200 MicroKiosk for CE .NET 4.2 Product Reference Guide

Table 4-1 Symbol Remote Device Manager Menu Items (Continued)

Menu Item

Function

RF Signal Strength

Launches the RF Signal Analyzer which displays RF signal strength. Only RF MK1200s running Mobile Companion support this feature. RF MK1200s running Aegis Client do not support this.

View Filter Parameters

Toggles on/off the Filter Parameters panel of the RDM.

Set Default Column Width

Sets the default column width for fields displayed in main RDM screen.

Actions Menu Locate Device

Initiates the device locating mechanism. Select an option for locating the device from the sub menu: Select Display Color Screen to display a color screen on the target device. Select Emit Sound to play a high-pitched sound clip from the target device. Select Display Color and Emit Sound to invoke both the previous two mechanisms in the target device. Select Terminate Locator mode to terminate the locating mechanism. This terminates the current locator mode before initiating another locator mode.

Ping Device

Ping the selected device. If the device cannot be reached, an error message displays.

Delete Device

Removes the selected device from the list of discovered devices. This only deletes the devices highlighted in gray.

Cold Boot

Cold boots the selected/highlighted MK1200(s). Allow approximately one minute for the device(s) to reboot and reconnect, then select View > Refresh to verify the devices rebooted successfully.

Warm Boot

Warm boots the selected/highlighted MK1200(s). Allow approximately one minute for the device(s) to reboot and reconnect, then select View > Refresh to verify the devices rebooted successfully.

Launch AirBeam

Launches the AirBeam version 2.16 application on the selected/highlighted MK1200(s). See Setting RDM Options on page 4-14.

Tools Menu Create Local Configuration File

Creates a new configuration file and allows saving it to the PC hard drive. See Creating a Configuration File on page 4-11.

Open Local Configuration File

Opens an existing configuration file that resides on the host computer.

Retrieve Remote Configuration File

Opens a configuration file that resides on the selected/highlighted MK1200.

Push Configuration File

Downloads a selected configuration file to the selected/highlighted MK1200(s). See Downloading the Configuration File to the MK1200 Using the RDM on page 4-13.

Page 79

Remote Device Manager

Table 4-1 Symbol Remote Device Manager Menu Items (Continued)

Menu Item

Function

Manage Static IP Address

Opens the Manage Static IP Address window. See Managing Static IP Addresses on page 4-20.

Custom DHCP Options

Displays the Customer DHCP Options window. Use this window to add/edit/remove DHCP options available within the Symbol RDM.

Options

Customizes Remote Device Manager options such as FTP security and broadcast IP address. See Setting RDM Options on page 4-14.

Symbol Remote Device Manager Toolbar Use the toolbar on the RDM main screen to perform the functions listed under the menu items in Table 4-2. Table 4-2 Symbol RDM Toolbar Components

Component

Description

Tool Bar

Contains buttons that invoke most common functions of RDM.

Discover all devices on the network and display the Discovered Devices list. To stop discovery, click the Cancel Discovery button.

Select all devices listed in the Discovered Devices list.

Deselect all devices.

Retrieve the configuration file from the selected device.

Push the configuration file to the selected device(s).

Abort pushing the configuration file to device(s).

Create an MK1200 device configuration file using the RDM.

Retrieve device specific information.

Cold boot the selected device.

Turns on and off the Filter Parameters panel.

4-7

Page 80

4-8

MK1200 MicroKiosk for CE .NET 4.2 Product Reference Guide

Row Colors The Symbol RDM uses a color scheme to indicate the state of the MK1200 devices. Table 4-3 Row Colors

Color

Status

Green

Successfully retrieved/pushed configuration file.

Yellow

Selected for downloading a configuration file.

Gray

Device is inactive. The device may be booting up or is no longer in the same subnet.

Red

The retrieval/pushing of the configuration file is unsuccessful.

State Icons The Symbol RDM uses a color scheme on the State Icons (the left most column) to indicate the state of the MK1200 devices. Table 4-4 State Icons

Color of Icon

Status Successfully discovered device.

Successfully retrieved/pushed configuration file.

Device is selected for downloading a configuration file.

Device is inactive. The device may be booting up or is no longer in the same subnet.

The retrieval/pushing of the configuration file is unsuccessful.

Page 81

Remote Device Manager

4-9

Filtering Parameters Use the Filter Parameters fields on the RDM main screen to display only certain devices on the network. Table 4-5 describes these fields. Table 4-5 Filter Parameters Fields

Menu Item

Function

Product Group

Select a product group to display.

Product

Select product model to display. See Identification on page 3-11.

Config Group 1

Select an assigned configuration group to display. To set configuration groups, use the System Configuration feature of RDM or System Menu. See Identification on page 3-11.

Config Group 2

Select a second assigned configuration group to display. To set configuration groups, use the System Configuration feature of RDM or System Menu. See Identification on page 3-11.

Location

Select a device location to display. To set locations, use the System Configuration feature of RDM or System Menu. See Identification on page 3-11.

Address Types

Select Static to display devices found in Manage Static IP Address list (see Managing Static IP Addresses on page 4-20), or Discovered to display all devices not in the Manage Static IP Address list (see Enabling DHCP on page 4-24).

IP Address

Enter IP address range to filter devices within the range.

Set the filtering parameters and click Apply Filter to apply the filters in RDM. Click Clear Filter to remove the filtering parameters.

Page 82

4 - 10 MK1200 MicroKiosk for CE .NET 4.2 Product Reference Guide

Filtering Example In Figure 4-6, the filter parameter is set to a configuration group called Technical to isolate a device used in the Technical department. When you click Apply Filter, the RDM scans the discovered devices list and filters out only the devices that fall into that configuration group. Use filters to quickly locate the devices.

Figure 4-6 Symbol Remote Device Manager Filtering

Electronic Serial Number An MK1200 shipped from the factory with CE .NET 4.2 has an electronic serial number accessible via network query. This information appears in RDM’s Serial Number column. A sample serial number is M1J37B90R.