Page 83

Remote Device Manager 4 - 11

Creating a Configuration File To create a new configuration file: 1.

From the Remote Device Manager, select Tools > Create Local Configuration File from the menu bar.

2.

In the Domains window, select the applicable domain/product (MK1200) and click OK. This opens the MK1200 Configuration Utility window.

3.

Make the necessary changes to the default values in the configuration file. See Default Parameters on page 3-6 for all configuration options, which fall into the following configuration categories:

• Configuration File Information - includes parameters related to version tracking of the mkconfig.reg file. • Applications - includes parameters related to Internet Explorer. • Communications - includes parameters for wired MK1200s related to Onboard Wired Ethernet. • System Configuration - includes parameters related to MK1200 system settings such as backlight intensity, volume and sounds, date/time, button configurations, regional settings, and user applications.

• Update - includes parameters related to the onboard FTP Client. • See Figure 4-7 for a sample screen, and Data Entry Formats on page 4-27 for MK1200 Configuration Utility window data entry field types used when changing configuration options.

Figure 4-7 Changing Configuration Parameters Example: Internet Explorer Start Page 4.

Select File > Save As.

5.

In the Save window, specify the file name and location, then click OK. NOTE

The default folder is C:\Program Files\Symbol\Configuration Utility\MK1200 Configuration Files. The default file name is mkconfig.reg. Assign the file any name, but rename the file mkconfig.reg before transferring it to the MK1200.

Page 84

4 - 12 MK1200 MicroKiosk for CE .NET 4.2 Product Reference Guide

Modifying an Existing Configuration File NOTE

If you upgraded the MK1200 OS to CE .NET 4.2 and a configuration (.reg) file was created using an older version, you must create a new .reg file using RDM Version 2.5 (see Creating a Configuration File on page 4-11). For more information about upgrades, see Appendix F, OS Upgrade Procedures..

To edit an existing configuration file: 1.

From the RDM on the host computer, choose Tools > Open Local Configuration File to open the MK1200 Configuration Utility window.

2.

Select a configuration file (with a .reg extension) to edit and click OK. NOTE

Only open files created by the RDM, System Menu, or Save Configuration. Loading other registry files can cause file corruption.

3.

Make the necessary changes to the default values in the configuration file. See Default Parameters on page 3-6 for these options. Also see Figure 4-7 for a sample screen, and Data Entry Formats on page 4-27 for MK1200 Configuration Utility window data entry field types used when changing configuration options.

4.

To save the changes, choose File > Save to overwrite the old file, or select Save As to specify a new name for the file. Note that you cannot change the Domain (product) of an existing configuration file.

Retrieving and Modifying a Configuration File from an MK1200 1.

From the RDM screen, select the device from which to retrieve the configuration file.

2.

Select Tools > Retrieve Remote Configuration File to retrieve the MK1200 configuration file from the MK1200 to the host computer. This launches the MK1200 Configuration Utility window of the RDM. If a configuration file is unavailable in the device, RDM opens the MK1200 Configuration Utility window with the default factory settings.

3.

Make the necessary changes to the default values in the configuration file. See Default Parameters on page 3-6 for these options. Also see Figure 4-7 for a sample screen, and Data Entry Formats on page 4-27 for MK1200 Configuration Utility window data entry field types used when changing configuration options.

4.

In the MK1200 Configuration Utility window, select File > Save to Remote Device to save the changes and transfer the updated configuration file back to the original MK1200.

5.

Alternatively, configure the RDM to automatically cold boot the MK1200 device after a download completes. Select Tools >Options to open the RDM Options screen, and check Auto reboot after download. NOTE

To reboot manually instead, in the RDM, select the MK1200 device, then select Actions > Cold Boot. Allow approximately one minute for the MK1200 to reboot and reconnect, then select View > Refresh to verify the device rebooted successfully.

Page 85

Remote Device Manager 4 - 13

Cloning an MK1200 Configuration File to Multiple MK1200s To use one MK1200 configuration file to configure other MK1200s: 1.

In the RDM, select the MK1200 with the configuration file to use.

2.

Select Tools > Retrieve Remote Configuration File to transfer the configuration file to the host computer and open the MK1200 Configuration Utility window.

3.

In the MK1200 Configuration Utility window, select File > Save As.

4.

Specify the location for the configuration file to be saved on the host PC, and click OK.

5.

Select the MK1200 devices to be updated from the Discovered Devices list.

6.

Select Tools > Push Configuration File option to upload the configuration file to the selected MK1200s (see Downloading the Configuration File to the MK1200 Using the RDM).

Downloading the Configuration File to the MK1200 Using the RDM To “push” the file to the MK1200(s): 1.

In the Symbol Remote Device Manager (RDM) window, select/highlight the MK1200(s) to receive the configuration file.

2.

Select Tools > Push Configuration File.

3.

Select the configuration file to send, then click Open. The row color of the selected device changes to yellow to indicate that the MK1200 device is ready to receive a configuration file through the RDM. When the download completes, the row color changes to green. See Row Colors on page 4-8 and State Icons on page 4-8.

4.

If the Auto reboot after download option is disabled, manually cold boot the MK1200(s). In the RDM main screen, select the MK1200(s) to reboot, then select Actions > Cold Boot. Allow approximately one minute for the MK1200 to reboot and reconnect, then select View > Refresh to verify the device rebooted successfully. NOTE

Setting the device FTP options to Enable Anonymous Login and Disable User Authentication allows anonymous login and retrieval of files through FTP connection. However, modifying/adding files is not allowed for non-anonymous users. Therefore, do not enter a user name and password in RDM’s options panel to download a file to the device through RDM if these FTP settings are in place.

Page 86

4 - 14 MK1200 MicroKiosk for CE .NET 4.2 Product Reference Guide

Setting RDM Options If desired, set the following Symbol Remote Device Manager (RDM) options from the Options window. These settings apply for the RDM:

• AirBeam parameters • FTP security • Timeouts • Auto-refresh • 3rd party application data • Other options (e.g., auto-reboot, device discovery). To set options: 1.

In the RDM main screen, select Tools > Options to open the Options window.

Figure 4-8 Symbol Remote Device Manager Options Window 2.

Set desired options:

• Set AirBeam Parameters for launching AirBeam. For more information on AirBeam command line parameters, refer to the AirBeam Package Builder Product Reference Guide.

• Set the FTP user ID in the User ID field and password in the Password field for accessing an FTP server. Leave this blank to enable anonymous FTP login. See Downloading the Configuration File to the MK1200 Using the RDM on page 4-13 and FTP Server on page 3-19.

• Enter a value for Device discovery (the duration for sending network queries for detecting MK1200 devices) and Query timeout (the timeout period before the next query).

Page 87

Remote Device Manager 4 - 15

• Check the Enable auto-refresh every option to enable automatic refresh/discovery of devices and specify the time period in its text box. This automatically refreshes the Discovered Devices list after a cold/warm boot or after a configuration file push.

• In the Application 1 and Application 2 fields, enter the names of applications loaded on the device that the RDM must monitor. For example, to track the Web Kiosk Software Suite version, enter Web_Kiosk SoftwareSuite into Application 1.

• Check Auto reboot after download to reboot the device after a successful configuration file push. • Check Device discovery on open to perform device discovery automatically when the RDM launches. • Check Enable RDM Password to prompt for a User Name and Password for using the RDM. Enter the user name and password in the RDM Login screen. RDM prompts for the user name and password when launched.

• Specify the Broadcast IP Address, used in discovering devices on the network. The default value is 255.255.255.255. This causes discovery of all device in all network interfaces attached to a single computer (multi-homed computer). 3.

Click OK to save the changes and close the Options window.

4.

Click Defaults to load the default settings for the RDM.

5.

Click Cancel to exit the RDM Options screen without saving the settings.

Monitoring MK1200s on a Network Use the RDM to remotely monitor MK1200s connected through a network connection. After performing discovery, double-click on an MK1200 from the discovery list, or click on the MK1200 in the list and select View > Device Information from the RDM menu:

• View device general information. See Device Information - Info Tab: Detected Device Information on page 4-16.

• View software version information, such as applications, drivers, OS, and platform. See Device Information Software Tab: Version Information on page 4-17.

• View RAM and flash memory usage for the selected device. See Device Information - Storage Tab: Memory Availability and Usage on page 4-18.

• View partition information for the selected MK1200. See Device Information - Partitions Tab on page 4-19. Use the up and down arrow keys to navigate through the discovered devices to view information. Click Refresh to refresh the device properties list. Click Generate Report to place the information displayed in the tabs into a printable file.

Page 88

4 - 16 MK1200 MicroKiosk for CE .NET 4.2 Product Reference Guide

Device Information - Info Tab: Detected Device Information The Info tab displays identification information about the selected MK1200. Also see Performing Discovery (Detection) of Devices on a Network on page 4-2

Figure 4-9 MK1200 Remote Device Monitor - Info Tab

Page 89

Remote Device Manager 4 - 17

Device Information - Software Tab: Version Information The Software tab displays the applications, operating system, monitor driver, and platform, and their version information for the selected MK1200.

Figure 4-10 MK1200 Remote Device Monitor - Software Tab

Page 90

4 - 18 MK1200 MicroKiosk for CE .NET 4.2 Product Reference Guide

Device Information - Storage Tab: Memory Availability and Usage The Storage tab displays storage areas on the selected MK1200, their physical size, and available free memory.

Figure 4-11 MK1200 Remote Device Monitor - Storage Tab

Page 91

Remote Device Manager 4 - 19

Device Information - Partitions Tab The Partitions tab displays the number and size of the storage areas on the selected MK1200.

Figure 4-12 MK1200 Remote Device Monitor - Partitions Tab

Page 92

4 - 20 MK1200 MicroKiosk for CE .NET 4.2 Product Reference Guide

Setting a Static IP Address To set a static IP address for a wired device: 1.

In the MK1200 Configuration Utility window, select IP Address under the appropriate adapter: Onboard Wired Ethernet.

Figure 4-13 Setting a Static IP Address 2.

In the text box, enter the IP address.

3.

Also select and define the adapter's Default Gateway and Subnet Mask.

4.

Optionally, select and define the DNS Server(s) and DNS Domain.

5.

Ensure that Enable DHCP is disabled (de-select its check box).

6.

Save the changes.

Managing Static IP Addresses Specify the static IP address of an MK1200, which is on a different subnet than the Symbol Remote Device Manager PC, to establish a connection and still be managed by the RDM. This causes the RDM to list the devices and their IP addresses, without performing discovery, in the RDM main screen. For this to occur, the MK1200 that is on a different subnet than the RDM must have a static (unchanging) IP address during the remote management session. This is useful when MK1200s are on more than one subnet, when bandwidth is a consideration, or when MK1200s are connected over a WAN. For example, if the MK1200 RF and wired Ethernet devices are on different subnets, the Remote Device Manager can still manage all devices.