Page 93

Remote Device Manager 4 - 21

Adding Static IP Addresses 1.

In the Symbol Remote Device Manager, select Tools > Manage Static Addresses.

Figure 4-14 Manage Static Addresses Window 2.

Enter the IP address and the name, and click Add. Repeat this to enter other static IP addresses.

3.

Click OK to save the changes.

Page 94

4 - 22 MK1200 MicroKiosk for CE .NET 4.2 Product Reference Guide

Modifying Static IP Addresses 1.

In the Symbol Remote Device Manager, select Tools > Manage Static IP Addresses.

Figure 4-15 Modifying Static Addresses 2.

Select the IP address and click Modify.

3.

Change the appropriate settings and click Update to update the static IP addresses list. Click Discard to discard the modifications.

4.

Click OK to save the changes.

Page 95

Remote Device Manager 4 - 23

Deleting Static IP Addresses 1.

In the Symbol Remote Device Manager, select Tools > Manage Static IP Addresses.

Figure 4-16 Deleting Static Addresses 2.

Select the IP address to delete, and click Delete. Repeat this to delete other static IP addresses.

3.

Click OK to save the changes.

Page 96

4 - 24 MK1200 MicroKiosk for CE .NET 4.2 Product Reference Guide

DHCP Configuration Familiarity with Dynamic Host Configuration Protocol (DHCP) options is required to edit options and save them to the configuration file. NOTE

Do not use the System Menu or RDM to enable DHCP receive options 1, 3, 6, 15, 44, 46, 47, 66 and 67. They are already enabled in dhcpoptions.reg as a part of the AirBeam package. Refer to AirBeam documentation for this configuration.

Enabling DHCP Enabling DHCP configures a specific network adapter to acquire its IP address and other network parameters through DHCP. DHCP options determine what additional data is sent to and received from the DHCP server. To enable DHCP: 1.

In the MK1200 Configuration Utility window, select Enable DHCP under the appropriate adapter: Onboard Wired Ethernet.

Figure 4-17 Enable DHCP Window 2.

Check Enable DHCP. NOTE

If enabling DHCP, you can set DHCP Server; however, this is usually not required. Do not set any other parameters under Communications.

If enabling DHCP to resolve addresses for a network adapter, optionally specify which data fields are sent from or received by the MK1200 (DHCP options) during DHCP transactions using that network adapter. Some of the 256 available DHCP options are defined by the IETF in RFC-2132, and appear in the MK1200 Configuration Utility window when specifying DHCP options. If desired, add custom DHCP options to this list. These custom option definitions are stored in the file <install_dir>\dhcpoptions.reg, which the RDM reads upon launch. If using another computer to edit a configuration file that contains custom DHCP options, transfer the file <install_dir>\dhcpoptions.reg to this computer to view these custom options.

Page 97

Remote Device Manager 4 - 25

To change Send DHCP options: 1.

In the MK1200 Configuration Utility window, select DHCP Options under the appropriate adapter: Onboard Wired Ethernet.

2.

Click Edit Send Options to view the Send window.

Figure 4-18 DHCP Send Options Window 3.

To add options to the configuration, select an option for the network adapter to receive from the Available Options list.

4.

In the data field(s) in the Static area of the window, enter the data to send for this option. Click to add these options to the Options to Receive list.

5.

To add other Send DHCP options, repeat steps 3 and 4.

6.

To remove options from the configuration, select an option to remove from the Options to Send list. Click to move the option back to the Available Options list. Repeat this for each option to remove.

7.

Click OK to save the changes and close the Send window.

Page 98

4 - 26 MK1200 MicroKiosk for CE .NET 4.2 Product Reference Guide

Custom DHCP Options Use the RDM to add/edit/remove custom DHCP options available within the RDM. Select Tools > Custom DHCP Options.

Figure 4-19 Custom DHCP Options Screen

Adding Custom DHCP Options Use the Custom DHCP Options window to add a new DHCP option. 1.

Select a code that is not currently used from the Code drop-down list.

2.

Enter the Name and Description for the custom DHCP option.

3.

Set the Input Rules.

4.

Click OK to submit the entered settings in the RDM.

Editing Custom DHCP Options 1.

From the Code drop-down list, select the custom DHCP option to edit.

2.

Make the appropriate changes.

3.

Click OK to submit the entered settings in the RDM.

Removing Custom DHCP Options 1.

From the Code drop-down list, select the custom DHCP option to remove.

2.

Delete the Name and Description.

3.

Click OK to save in the RDM.

Page 99

Remote Device Manager 4 - 27

Updating the RDM on the Host Computer To update the RDM: 1.

Use the Windows® Add/Remove a Program utility to remove the RDM from the host computer.

2.

Install an updated RDM. See Installing the Symbol Remote Device Manager on page 4-3.

Restoring Configuration Parameter Defaults Some fields have a default value. To restore default values, choose one of the following items from the MK1200 Configuration Utility window:

• Select a parameter, then select Edit >Restore Default to restore the current field to its default. • Select Edit > Restore All Defaults to restore all parameter default settings. Save the changes.

Data Entry Formats The RDM uses standard data entry formats, depending on the data type:

• Check Box: Used for true or false values. An "X" in the check box selects the function. Tap the box to check or uncheck.

• Text Data Entry Box: Requires text entry. Examples are IP address, domain name, or server name. • Numeric Data Entry Box: Requires numeric entries, in hexadecimal (base 16) or decimal (base 10) notation. Hex values must be preceded by "0x".

• Drop-down List: Select a single option. The stored parameter value may be different than the text displayed. • Bit Fields: Multiple items with check boxes. If desired, select multiple items (from none to all). Each selected item affects the value stored, which is a single number, so the selections will not match the mkconfig.reg file.

• Multiple Text: Enter multiple free-form strings. Click Enter on the keyboard to create a new string. Multiple text values are not represented in the mkconfig.reg file as text, so the value entered is not recognizable in the mkconfig.reg file.

• External-type: For each different external type, an associated DLL manipulates what is stored in the Registry (mkconfig.reg) and how it is displayed in the Configuration Utility/System Menu. The Configuration Utility/System Menu loads the relevant DLL when an External-type is found in the metadata file for the particular Registry type. The DLL should have two standard methods: input and output. When a registry entry of External- type is stored, the text in the text box is passed to the output method of the DLL which translates the data accordingly and writes it to the Registry file. When retrieving a Registry entry, the DLL invokes the input method and translates the data back to a valid form. It is displayed in the Configuration Utility /System Menu. All validation for the value entered is done through the DLL. No validation is done through the Configuration Utility/System Menu. This method is used in encrypting and decrypting WEP keys.

Page 100