Page 56
3 - 10 MK1200 MicroKiosk for CE .NET 4.2 Product Reference Guide
Table 3-5 System Configuration Default Parameters (Continued)
System Configuration Parameters Button Security
Date and Time Settings Time Zone
Daylight Saving
Description Enables/disables the button security functionality on the MK1200 device. Check to lock the buttons. These can only be unlocked by entering the button security password.
Default Enabled
Date and Time Configuration Standard time zone. Drop-down list of time zone names, such as "Pacific Standard Time", or "South Africa Standard Time". Select the appropriate time zone.
Pacific Standard Time
Daylight Saving Configuration
AutoDST
Check to enable daylight saving time for the current time zone. Use this setting for non-explorer.exe based application. When enabled, the Windows Explorer shell uses this setting to set the system time for daylight saving. Use this setting if the application runs with the Windows Explorer shell.
Enabled
HomeDST
Check to enable daylight saving time for the current time zone. Use this setting if application does not run with Windows Explorer shell, for example when developing a browser (Kiosk IE) based application.
Enabled
Device Activity Management
There are three slots with identical parameters: First Activity Configuration Second Activity Configuration Third Activity Configuration See Device Activity Management (Sleep/Wake-up Functionality) on page 3-17.
Items
Devices to apply activity scheme to.
All
Days
Set of days on which to apply this activity scheme (Monday through Sunday).
None
On Time
Time when device is activated, using 24 hour clock representation. Set this value for correct functioning of the Device Activity Manager.
None
Page 57
Configuration 3 - 11
Table 3-5 System Configuration Default Parameters (Continued)
System Configuration Parameters Off Time
Error Reporting
Description Time when device is deactivated, using 24 hour clock representation. Set this value for correct functioning of the Device Activity Manager.
Default None
Error Reporting Configuration
Low Memory Settings
Configuration of Low Memory Settings
Object Store Min Size
Minimum size of object store to allow RAM to borrow from it.
1048576
RAM Expansion Block Size
System adjusts RAM/Object Store percentage to provide more RAM in low memory conditions. Values range from 64K to 1MB. Set to 0 to disable RAM expansion.
1048576
Show Error Messages
Determines whether the system displays dialogs when low memory problems occur.
Disabled
Identification
General Configuration
Name
Specifies device name.
None
Description
Specifies device description.
None
Contact
Contact details of the system administrator.
System contact here
Location
Specifies the location of the device.
Device location here
Configuration Group 1
First user-definable string. Intended for use when grouping devices to aid configuration. Can be used as part of device filter in RDM.
None
Configuration Group 2
Second user-definable string. Intended for use when grouping devices to aid configuration. Can be used as part of device filter in RDM.
None
Inactivity Manager
Inactivity Manager Configuration (see Inactivity Application (Screen Saver) on page 7-12)
Inactivity Application Name
Inactivity application.
\\Windows\\SimpleSaver.exe
Idle Time Before Launch
Idle time before inactivity application launches, in seconds.
0 (0x0 hex)
Page 58
3 - 12 MK1200 MicroKiosk for CE .NET 4.2 Product Reference Guide
Table 3-5 System Configuration Default Parameters (Continued)
System Configuration Parameters Memory Allocation SystemStorePercent
Network Time Update
Description
Default
Memory Partition of Storage Memory and System Memory Percentage of memory used for the storage memory. The remaining memory is allocated to program memory (memory used to run programs). Half the unused RAM is used, when the value assigned to SystemStorePercent does not provide enough memory for the device to operate normally. This parameter only configures unused RAM.
50 (0x32 hex)
Configuration of Simple Network Time Protocol service (see Network Time Update: SNTP Client on page 7-10 for details)
Time Server
Specifies the domain name of the time server to contact for updates. If no time server is set in the field, the time service is disabled. Do not set an IP address for this parameter. If the MK1200 is unable to obtain a time value from the time server, it uses the default setting (June 1, 1999 12:00:00 PM), and does not re-attempt to acquire a time value unless a regular update is also configured (the next attempt occurs at the configured time).
tock.usno.navy.mil
Refresh
Specifies the time period, in milliseconds, between synchronizations with the SNTP server.
1209600000 (0x48190800 hex)
Recovery Refresh
Specifies the time period, in milliseconds, until next synchronization, if the previous synchronization attempt failed.
86400000 (0x5265c00 hex)
Threshold
Specifies the interval between the time on the SNTP server and the current time in milliseconds. If the difference between the SNTP server time and the local system time is larger than the specified value in Threshold parameter, the update is ignored unless the system clock is presumed incorrect.
86400000 (0x5265c00 hex)
Page 59
Configuration 3 - 13
Table 3-5 System Configuration Default Parameters (Continued)
System Configuration Parameters Printer Configuration
Description
Default
Printer Configuration (see Printing on page 3-17)
Active Printer
Use this parameter to set the active printer. Select the printer from the list.
Zebra (QL320, Cameo, Encore)
Zebra QL Series
Specifies the baud rate for the selected active printer if the selected active printer is a Zebra QL Series printer.
19200
Zebra QL Series Flow Control
Specifies the flow control of the active printer if the selected active printer is a Zebra QL Series printer.
None
Zebra EPL Series
Specifies the baud rate of the active printer if the selected active printer is a Zebra EPL Series printer. For a list of supported EPL printers, see Printing on page 3-17.
9600
Zebra EPL Series Flow Control
Specifies the flow control of the active printer if the selected active printer is a Zebra EPL Series printer. For a list of supported EPL printers, see Printing on page 3-17.
None
Zebra ZPL Series
Specifies the baud rate of the active printer if the selected active printer is a Zebra ZPL Series printer. For a list of supported ZPL printers, see Printing on page 3-17.
9600
Zebra ZPL Series Flow Control
Specifies the flow control of the active printer if the selected active printer is a Zebra ZPL Series printer. For a list of supported ZPL printers, see Printing on page 3-17.
None
Epson TML90
Specifies the baud rate of the active printer if the selected active printer is a Epson TML90 printer.
9600
Epson TML90 Flow Control
Specifies the flow control of the active printer if the selected active printer is a Epson TML90 printer.
None
Epson TMT88III
Specifies the baud rate of the active printer if the selected active printer is a Epson TMT88III printer.
9600
Epson TMT88III Flow Control
Specifies the flow control of the active printer if the selected active printer is a Epson TMT88III printer.
None
Page 60
3 - 14 MK1200 MicroKiosk for CE .NET 4.2 Product Reference Guide
Table 3-5 System Configuration Default Parameters (Continued)
System Configuration Parameters Protected Mode
Description
Default
Gate Keeper Configuration (see Password Protection (Gate Keeper) on page 7-7)
Password
Required for Protected Mode access. Buttons are assigned numeric values from left to right (A=1, D=4).
44213 (denoted with *****)
Application
Application to run in Protected Mode.
\windows\explorer.exe
Regional Settings - General
HTML in web pages does not use regional settings without programmatic support. To use regional settings, script in web pages must format dates, times, currency, and numbers using built-in functions that take the regional settings into account. This is the only method of using the regional settings in a browser. C/C++ apps can use regional settings through the standard Windows CE API.
Regional Settings - Date
Configuration of Date Regional Settings
Long Date
Long date format.
dddd, MMMM dd, yyyy
Short Date
Short date format.
M/d/yyyy
Short Date Separator
Character uses as the short date separator.
/
Regional Settings - Time
Configuration of Time Regional Settings
PM indicator
PM indicator.
PM
AM indicator
AM indicator.
AM
Time Separator
Time separator (generally 1 character).
:
Leading Zero
Display leading zero for hours/minutes/seconds.
Disabled
Time Format
Time format.
h:mm:ss tt
Regional Settings - Currency
Configuration of Currency Regional Settings
Digits In Group
Number of digits allowed in a group.
0
Grouping Symbol
Digit grouping symbol (generally zero or one character).
,
Digits After Decimal
The number of digits allowed after a decimal point.
0
Decimal Symbol
Decimal symbol (one character).
.
Negative Format
Format for negative currency values. The asterisk (\"*\") denotes the universal currency symbol. The period (\".\") indicates the chosen decimal separator.
(*1.1)
Page 61
Configuration 3 - 15
Table 3-5 System Configuration Default Parameters (Continued)
System Configuration Parameters
Description
Currency Symbol Position
Position of currency symbol. The asterisk (\"*\") denotes the universal currency symbol. The period (\".\") indicates the chosen decimal separator.
*1.1
Currency Symbol
Currency symbol.
$
Regional Settings - Numbers
Configuration of Number Regional Settings
List Separators
List separators (character).
None
Measurement System
Measurement system.
Metric
Display Leading Zero
Display leading zero.
Enabled
Negative Number Format
Negative number format. The period (\".\") indicates the chosen decimal separator.
-1.1
Negative Sign
Negative sign (generally one character).
-
Digits In Group
Number of digits in group.
3
Grouping Symbol
Digit grouping symbol (generally zero or one character).
,
Digits After Decimal
The number of digits allowed after a decimal point.
0
Decimal Symbol
Decimal symbol (one character).
.
Screen Taps
Default
Screen Tap Configuration
Double-Click Distance
Specifies the maximum number of pixels between two screen taps to qualify the screen taps as a double-click. Use this parameter to differentiate double-clicks from screen taps.
6 (0x6 hex)
Double-Click Speed
Specifies the maximum number of milliseconds between two screen taps to qualify the screen taps as a double-click. Use this parameter to differentiate double-clicks from screen taps.
500 (0x1f4 hex)
Page 62
3 - 16 MK1200 MicroKiosk for CE .NET 4.2 Product Reference Guide
Table 3-5 System Configuration Default Parameters (Continued)
System Configuration Parameters User Apps
Description
Default
There are seven user application slots, with identical parameters. Each slot is under a group called “X Application Launched”, where “X” is First, Second, etc. See Configuring User Application(s) on page 3-18 for details.
Application Path
Full path to application.
First application slot: \windows\explorer.exe Remaining slots: None
Arguments
Command line arguments for the program (UNICODE string).
None
Delay Before Launch
Number of seconds to delay before launching program.
0x0
Waiting For Completion
Specifies whether to wait for program to complete before proceeding.
Disabled
Volume and Sounds
Volume and Sound Configuration
Button Press Sounds
Configuration of Button Press Sounds
Duration
Duration of time to play the sound in milliseconds (ms). Value must be non-zero before you can hear sound.
8 ms
Frequency
Frequency of sound to play in Hertz (Hz).
400 Hz
Volume
Volume of sound to play when you press a button (single or combination). Set to 0 to disable button press sounds.
Medium
Scanner Beep
Configuration of Scanner Beep
Volume
Volume of scanner beep on a good decode.
Screen Tap Sounds
Configuration of Screen Tap Sounds
Duration
Duration of time to play the sound in milliseconds (ms). Value must be non-zero before you can hear sound.
8 ms
Frequency
Frequency of sound to play in Hertz (Hz).
400 Hz
Volume
Volume of sound to play when you tap the screen. Set to 0 to disable screen tap sounds.
Medium
Web Server
Web Server in MK1200 Configuration
Enable WebServer
Enables/disables the Web Server in the device.
High
Enable
Page 63
Configuration 3 - 17
Device Activity Management (Sleep/Wake-up Functionality) Use the Device Activity Manager to manage the device usage profile and lifecycle by turning on/off the scan engine laser and the display backlight. Set the sleep and wake-up times by day, weekday, weekend, etc. When setting the time, use the 24-hour clock in the format hh:mm. NOTE
It is strongly advised to use the Device Activity Management functionality.
If the Device Activity Manager (DAM) puts the scan engine and/or backlight into sleep mode, these subsystems repower (wake up) upon the following events:
• a button press • a display touch. The DAM only checks whether to turn devices on or off when the Inactivity Application Timeout expires. If a device wakes up due to user input (a “wakeup”), it remains awake regardless of user input until another timeout expires, then goes back to sleep. To use the DAM without the Inactivity Application Manager, configure the Inactivity Application Timeout to the default wakeup time and set the Inactivity Application parameter to nothing. NOTE
Use the RDM or System Menu to set up the Device Activity Manager. Enter valid values to all DAM parameters (see page 3-10). Otherwise the system rejects the input values and the DAM does not invoke the Inactivity Application.
Printing The MK1200 supports printing text, bar codes, and bitmaps in the following environments:
• Browser applications • C/C++ applications. The MK1200 transmits data to a printer using an RS-232 serial connection. RS-232 serial port settings (port, stop bits, data bits, parity) are shared with the tethered scanner. Table 3-5 contains the default baud rate settings for the following printers:
• Zebra (QL320, Cameo, Encore) • Zebra (LP2824/TLP2844)* • Zebra EPL Series (LP/TLP 2824, LP/TLP 2844, TLP 3842) • Zebra ZPL (LP/TLP 2844-Z, TLP 3844-Z) • Epson TML90 • Epson TMT88III. * Zebra LP printers ship in Gap mode. If using a printer in Continuous Paper mode, the autosense does not work and you must manually set the gap to zero. To avoid this, send a command to the printer to change the mode. Refer to the Zebra printer documentation.
Page 64
3 - 18 MK1200 MicroKiosk for CE .NET 4.2 Product Reference Guide
Advanced Printer Monitoring Functionality For some printers, such as the Zebra QL Series, the MK1200 supports advanced printer monitoring functionality, such as:
• Detecting if the printer cable is connected • Detecting if the printer power is on • Detecting if the printer is out of paper • Detecting if the printer door is open.
Configuring User Application(s) The MK1200 Configuration Utility window configures the launching of user application(s). The seven definable application "slots" are processed upon power up. Programs launch in sequence with no delay, unless you set the Delay Before Launch or Waiting For Completion parameter. The Startup program supports four parameters for each slot, detailed in Table 3-6: executable path, command line arguments, delay before running, and a special flag. Table 3-6 User Applications, Parameter Descriptions
Parameter
Description
Application Path
The full “run” path to the executable. Define this in order to process the entry (i.e., do not just specify a delay). File type associations are not supported. For example if the Argument contains a word document, specify the full path to wordpad.exe in the Application Path.
Arguments
Optional. Command line arguments for the program above. Escape double quotation marks using a back slash character, as in \". Also escape back slashes, i.e., \\.
Delay Before Launch
Optional. Specifies the number of seconds to delay before launching the User Application, if a previous program needs to complete or to ensure system resources are available. This is a simple way to handle sequencing; see Reliable Sequencing of Application Programs on page 3-18 for more complex situations (requires “wait for completion”).
Waiting For Completion
Specifies whether the startup sequence waits for this program to complete before launching the next one, typically set to FALSE. See Reliable Sequencing of Application Programs on page 3-18.
Reliable Sequencing of Application Programs Use the Delay Before Launch and Wait for Completion parameters to set the startup process parameters:
• If an application requires a definitive order of execution • To provide a signal between components to detect failures • To verify that local or networked resources are available before the main application launches. Use the Delay Before Launch parameter to achieve a delay in the launch sequence. However, this is not a robust way to ensure correct system operation. The recommended method is to write a separate program, with or without a user interface, that performs required checks then terminates, possibly setting a registry value or filesystem flag to indicate success. Set the Wait For Completion flag and run this program before running the main application(s).