Page 56

3 - 10 MK1200 MicroKiosk for CE .NET 4.2 Product Reference Guide

Table 3-5 System Configuration Default Parameters (Continued)

System Configuration Parameters Button Security

Date and Time Settings Time Zone

Daylight Saving

Description Enables/disables the button security functionality on the MK1200 device. Check to lock the buttons. These can only be unlocked by entering the button security password.

Default Enabled

Date and Time Configuration Standard time zone. Drop-down list of time zone names, such as "Pacific Standard Time", or "South Africa Standard Time". Select the appropriate time zone.

Pacific Standard Time

Daylight Saving Configuration

AutoDST

Check to enable daylight saving time for the current time zone. Use this setting for non-explorer.exe based application. When enabled, the Windows Explorer shell uses this setting to set the system time for daylight saving. Use this setting if the application runs with the Windows Explorer shell.

Enabled

HomeDST

Check to enable daylight saving time for the current time zone. Use this setting if application does not run with Windows Explorer shell, for example when developing a browser (Kiosk IE) based application.

Enabled

Device Activity Management

There are three slots with identical parameters: First Activity Configuration Second Activity Configuration Third Activity Configuration See Device Activity Management (Sleep/Wake-up Functionality) on page 3-17.

Items

Devices to apply activity scheme to.

All

Days

Set of days on which to apply this activity scheme (Monday through Sunday).

None

On Time

Time when device is activated, using 24 hour clock representation. Set this value for correct functioning of the Device Activity Manager.

None

Page 57

Configuration 3 - 11

Table 3-5 System Configuration Default Parameters (Continued)

System Configuration Parameters Off Time

Error Reporting

Description Time when device is deactivated, using 24 hour clock representation. Set this value for correct functioning of the Device Activity Manager.

Default None

Error Reporting Configuration

Low Memory Settings

Configuration of Low Memory Settings

Object Store Min Size

Minimum size of object store to allow RAM to borrow from it.

1048576

RAM Expansion Block Size

System adjusts RAM/Object Store percentage to provide more RAM in low memory conditions. Values range from 64K to 1MB. Set to 0 to disable RAM expansion.

1048576

Show Error Messages

Determines whether the system displays dialogs when low memory problems occur.

Disabled

Identification

General Configuration

Name

Specifies device name.

None

Description

Specifies device description.

None

Contact

Contact details of the system administrator.

System contact here

Location

Specifies the location of the device.

Device location here

Configuration Group 1

First user-definable string. Intended for use when grouping devices to aid configuration. Can be used as part of device filter in RDM.

None

Configuration Group 2

Second user-definable string. Intended for use when grouping devices to aid configuration. Can be used as part of device filter in RDM.

None

Inactivity Manager

Inactivity Manager Configuration (see Inactivity Application (Screen Saver) on page 7-12)

Inactivity Application Name

Inactivity application.

\\Windows\\SimpleSaver.exe

Idle Time Before Launch

Idle time before inactivity application launches, in seconds.

0 (0x0 hex)

Page 58

3 - 12 MK1200 MicroKiosk for CE .NET 4.2 Product Reference Guide

Table 3-5 System Configuration Default Parameters (Continued)

System Configuration Parameters Memory Allocation SystemStorePercent

Network Time Update

Description

Default

Memory Partition of Storage Memory and System Memory Percentage of memory used for the storage memory. The remaining memory is allocated to program memory (memory used to run programs). Half the unused RAM is used, when the value assigned to SystemStorePercent does not provide enough memory for the device to operate normally. This parameter only configures unused RAM.

50 (0x32 hex)

Configuration of Simple Network Time Protocol service (see Network Time Update: SNTP Client on page 7-10 for details)

Time Server

Specifies the domain name of the time server to contact for updates. If no time server is set in the field, the time service is disabled. Do not set an IP address for this parameter. If the MK1200 is unable to obtain a time value from the time server, it uses the default setting (June 1, 1999 12:00:00 PM), and does not re-attempt to acquire a time value unless a regular update is also configured (the next attempt occurs at the configured time).

tock.usno.navy.mil

Refresh

Specifies the time period, in milliseconds, between synchronizations with the SNTP server.

1209600000 (0x48190800 hex)

Recovery Refresh

Specifies the time period, in milliseconds, until next synchronization, if the previous synchronization attempt failed.

86400000 (0x5265c00 hex)

Threshold

Specifies the interval between the time on the SNTP server and the current time in milliseconds. If the difference between the SNTP server time and the local system time is larger than the specified value in Threshold parameter, the update is ignored unless the system clock is presumed incorrect.

86400000 (0x5265c00 hex)

Page 59

Configuration 3 - 13

Table 3-5 System Configuration Default Parameters (Continued)

System Configuration Parameters Printer Configuration

Description

Default

Printer Configuration (see Printing on page 3-17)

Active Printer

Use this parameter to set the active printer. Select the printer from the list.

Zebra (QL320, Cameo, Encore)

Zebra QL Series

Specifies the baud rate for the selected active printer if the selected active printer is a Zebra QL Series printer.

19200

Zebra QL Series Flow Control

Specifies the flow control of the active printer if the selected active printer is a Zebra QL Series printer.

None

Zebra EPL Series

Specifies the baud rate of the active printer if the selected active printer is a Zebra EPL Series printer. For a list of supported EPL printers, see Printing on page 3-17.

9600

Zebra EPL Series Flow Control

Specifies the flow control of the active printer if the selected active printer is a Zebra EPL Series printer. For a list of supported EPL printers, see Printing on page 3-17.

None

Zebra ZPL Series

Specifies the baud rate of the active printer if the selected active printer is a Zebra ZPL Series printer. For a list of supported ZPL printers, see Printing on page 3-17.

9600

Zebra ZPL Series Flow Control

Specifies the flow control of the active printer if the selected active printer is a Zebra ZPL Series printer. For a list of supported ZPL printers, see Printing on page 3-17.

None

Epson TML90

Specifies the baud rate of the active printer if the selected active printer is a Epson TML90 printer.

9600

Epson TML90 Flow Control

Specifies the flow control of the active printer if the selected active printer is a Epson TML90 printer.

None

Epson TMT88III

Specifies the baud rate of the active printer if the selected active printer is a Epson TMT88III printer.

9600

Epson TMT88III Flow Control

Specifies the flow control of the active printer if the selected active printer is a Epson TMT88III printer.

None

Page 60

3 - 14 MK1200 MicroKiosk for CE .NET 4.2 Product Reference Guide

Table 3-5 System Configuration Default Parameters (Continued)

System Configuration Parameters Protected Mode

Description

Default

Gate Keeper Configuration (see Password Protection (Gate Keeper) on page 7-7)

Password

Required for Protected Mode access. Buttons are assigned numeric values from left to right (A=1, D=4).

44213 (denoted with *****)

Application

Application to run in Protected Mode.

\windows\explorer.exe

Regional Settings - General

HTML in web pages does not use regional settings without programmatic support. To use regional settings, script in web pages must format dates, times, currency, and numbers using built-in functions that take the regional settings into account. This is the only method of using the regional settings in a browser. C/C++ apps can use regional settings through the standard Windows CE API.

Regional Settings - Date

Configuration of Date Regional Settings

Long Date

Long date format.

dddd, MMMM dd, yyyy

Short Date

Short date format.

M/d/yyyy

Short Date Separator

Character uses as the short date separator.

/

Regional Settings - Time

Configuration of Time Regional Settings

PM indicator

PM indicator.

PM

AM indicator

AM indicator.

AM

Time Separator

Time separator (generally 1 character).

:

Leading Zero

Display leading zero for hours/minutes/seconds.

Disabled

Time Format

Time format.

h:mm:ss tt

Regional Settings - Currency

Configuration of Currency Regional Settings

Digits In Group

Number of digits allowed in a group.

0

Grouping Symbol

Digit grouping symbol (generally zero or one character).

,

Digits After Decimal

The number of digits allowed after a decimal point.

0

Decimal Symbol

Decimal symbol (one character).

.

Negative Format

Format for negative currency values. The asterisk (\"*\") denotes the universal currency symbol. The period (\".\") indicates the chosen decimal separator.

(*1.1)

Page 61

Configuration 3 - 15

Table 3-5 System Configuration Default Parameters (Continued)

System Configuration Parameters

Description

Currency Symbol Position

Position of currency symbol. The asterisk (\"*\") denotes the universal currency symbol. The period (\".\") indicates the chosen decimal separator.

*1.1

Currency Symbol

Currency symbol.

$

Regional Settings - Numbers

Configuration of Number Regional Settings

List Separators

List separators (character).

None

Measurement System

Measurement system.

Metric

Display Leading Zero

Display leading zero.

Enabled

Negative Number Format

Negative number format. The period (\".\") indicates the chosen decimal separator.

-1.1

Negative Sign

Negative sign (generally one character).

-

Digits In Group

Number of digits in group.

3

Grouping Symbol

Digit grouping symbol (generally zero or one character).

,

Digits After Decimal

The number of digits allowed after a decimal point.

0

Decimal Symbol

Decimal symbol (one character).

.

Screen Taps

Default

Screen Tap Configuration

Double-Click Distance

Specifies the maximum number of pixels between two screen taps to qualify the screen taps as a double-click. Use this parameter to differentiate double-clicks from screen taps.

6 (0x6 hex)

Double-Click Speed

Specifies the maximum number of milliseconds between two screen taps to qualify the screen taps as a double-click. Use this parameter to differentiate double-clicks from screen taps.

500 (0x1f4 hex)

Page 62

3 - 16 MK1200 MicroKiosk for CE .NET 4.2 Product Reference Guide

Table 3-5 System Configuration Default Parameters (Continued)

System Configuration Parameters User Apps

Description

Default

There are seven user application slots, with identical parameters. Each slot is under a group called “X Application Launched”, where “X” is First, Second, etc. See Configuring User Application(s) on page 3-18 for details.

Application Path

Full path to application.

First application slot: \windows\explorer.exe Remaining slots: None

Arguments

Command line arguments for the program (UNICODE string).

None

Delay Before Launch

Number of seconds to delay before launching program.

0x0

Waiting For Completion

Specifies whether to wait for program to complete before proceeding.

Disabled

Volume and Sounds

Volume and Sound Configuration

Button Press Sounds

Configuration of Button Press Sounds

Duration

Duration of time to play the sound in milliseconds (ms). Value must be non-zero before you can hear sound.

8 ms

Frequency

Frequency of sound to play in Hertz (Hz).

400 Hz

Volume

Volume of sound to play when you press a button (single or combination). Set to 0 to disable button press sounds.

Medium

Scanner Beep

Configuration of Scanner Beep

Volume

Volume of scanner beep on a good decode.

Screen Tap Sounds

Configuration of Screen Tap Sounds

Duration

Duration of time to play the sound in milliseconds (ms). Value must be non-zero before you can hear sound.

8 ms

Frequency

Frequency of sound to play in Hertz (Hz).

400 Hz

Volume

Volume of sound to play when you tap the screen. Set to 0 to disable screen tap sounds.

Medium

Web Server

Web Server in MK1200 Configuration

Enable WebServer

Enables/disables the Web Server in the device.

High

Enable

Page 63

Configuration 3 - 17

Device Activity Management (Sleep/Wake-up Functionality) Use the Device Activity Manager to manage the device usage profile and lifecycle by turning on/off the scan engine laser and the display backlight. Set the sleep and wake-up times by day, weekday, weekend, etc. When setting the time, use the 24-hour clock in the format hh:mm. NOTE

It is strongly advised to use the Device Activity Management functionality.

If the Device Activity Manager (DAM) puts the scan engine and/or backlight into sleep mode, these subsystems repower (wake up) upon the following events:

• a button press • a display touch. The DAM only checks whether to turn devices on or off when the Inactivity Application Timeout expires. If a device wakes up due to user input (a “wakeup”), it remains awake regardless of user input until another timeout expires, then goes back to sleep. To use the DAM without the Inactivity Application Manager, configure the Inactivity Application Timeout to the default wakeup time and set the Inactivity Application parameter to nothing. NOTE

Use the RDM or System Menu to set up the Device Activity Manager. Enter valid values to all DAM parameters (see page 3-10). Otherwise the system rejects the input values and the DAM does not invoke the Inactivity Application.

Printing The MK1200 supports printing text, bar codes, and bitmaps in the following environments:

• Browser applications • C/C++ applications. The MK1200 transmits data to a printer using an RS-232 serial connection. RS-232 serial port settings (port, stop bits, data bits, parity) are shared with the tethered scanner. Table 3-5 contains the default baud rate settings for the following printers:

• Zebra (QL320, Cameo, Encore) • Zebra (LP2824/TLP2844)* • Zebra EPL Series (LP/TLP 2824, LP/TLP 2844, TLP 3842) • Zebra ZPL (LP/TLP 2844-Z, TLP 3844-Z) • Epson TML90 • Epson TMT88III. * Zebra LP printers ship in Gap mode. If using a printer in Continuous Paper mode, the autosense does not work and you must manually set the gap to zero. To avoid this, send a command to the printer to change the mode. Refer to the Zebra printer documentation.

Page 64

3 - 18 MK1200 MicroKiosk for CE .NET 4.2 Product Reference Guide

Advanced Printer Monitoring Functionality For some printers, such as the Zebra QL Series, the MK1200 supports advanced printer monitoring functionality, such as:

• Detecting if the printer cable is connected • Detecting if the printer power is on • Detecting if the printer is out of paper • Detecting if the printer door is open.

Configuring User Application(s) The MK1200 Configuration Utility window configures the launching of user application(s). The seven definable application "slots" are processed upon power up. Programs launch in sequence with no delay, unless you set the Delay Before Launch or Waiting For Completion parameter. The Startup program supports four parameters for each slot, detailed in Table 3-6: executable path, command line arguments, delay before running, and a special flag. Table 3-6 User Applications, Parameter Descriptions

Parameter

Description

Application Path

The full “run” path to the executable. Define this in order to process the entry (i.e., do not just specify a delay). File type associations are not supported. For example if the Argument contains a word document, specify the full path to wordpad.exe in the Application Path.

Arguments

Optional. Command line arguments for the program above. Escape double quotation marks using a back slash character, as in \". Also escape back slashes, i.e., \\.

Delay Before Launch

Optional. Specifies the number of seconds to delay before launching the User Application, if a previous program needs to complete or to ensure system resources are available. This is a simple way to handle sequencing; see Reliable Sequencing of Application Programs on page 3-18 for more complex situations (requires “wait for completion”).

Waiting For Completion

Specifies whether the startup sequence waits for this program to complete before launching the next one, typically set to FALSE. See Reliable Sequencing of Application Programs on page 3-18.

Reliable Sequencing of Application Programs Use the Delay Before Launch and Wait for Completion parameters to set the startup process parameters:

• If an application requires a definitive order of execution • To provide a signal between components to detect failures • To verify that local or networked resources are available before the main application launches. Use the Delay Before Launch parameter to achieve a delay in the launch sequence. However, this is not a robust way to ensure correct system operation. The recommended method is to write a separate program, with or without a user interface, that performs required checks then terminates, possibly setting a registry value or filesystem flag to indicate success. Set the Wait For Completion flag and run this program before running the main application(s).