Page 47

Chapter 3 Configuration Introduction This chapter describes how to set up and configure the MK1200 applications, communications, and network settings which include parameters such as the device name, internet browser settings, date and time, and several other key settings. Configure these settings remotely using the Symbol Remote Device Manager (RDM), or locally on the MK1200 using the System Menu. These settings are saved in the configuration registry file (mkconfig.reg) in the MK1200 Application folder to maintain them across cold boot cycles. Table 3-1 Methods of Configuring the MK1200

Configuration Method Remote Device Manager (RDM)

Remote

Local

X

System Menu

X

Control Panel

X

Remote Configuration using Symbol Remote Device Manager Use the Symbol Remote Device Manager (RDM) to configure parameters remotely. RDM is a Windows®-based utility that runs on a host computer and generates/edits an MK1200 configuration file (mkconfig.reg). Load this file onto the MK1200 and reboot the MK1200 to configure the device. See Chapter 4, Remote Device Manager for more details.

Local Configuration Using the System Menu (Touch Screen Devices Only) The System Menu function sets configuration parameters locally on the MK1200. The System Menu is similar to the MK1200 Configuration Utility window of the RDM, except the virtual keyboard is used to enter information. From within the System menu, use the File > Save option to save the changes and update the configuration registry file (mkconfig.reg). The new settings are invoked upon the next cold boot. See System Menu on page 3-5.

Page 48

3-2

MK1200 MicroKiosk for CE .NET 4.2 Product Reference Guide

Using the Microsoft Windows Control Panel The Control Panel on the MK1200 Start menu changes a limited number of parameters. If desired, use the Control Panel to change the functions listed in Control Panel Configuration Parameters on page 3-20; however Symbol recommends only changing the Stylus Settings/Touch Screen Calibration, Backlight, and Contrast settings using the Control Panel. To save changes to the mkconfig.reg configuration file, select Start > Programs > Save Configuration to maintain the settings across cold boot cycles. NOTE

Touch Screen calibration and Backlight contrast persist regardless of whether you use Save Configuration. There are also some Control Panel settings which do not persist across cold boot cycles.

Updating the Device Configuration File Use one of the following methods to update the device configuration file (mkconfig.reg) locally on the MK1200.

• Start > Programs > Save Configuration

Figure 3-1 Save Configuration Screens

The Save Configuration option uses the current registry parameter values and writes them to the mkcofig.reg file. The windows shown in Figure 3-1 appear while the file is saved and written. Not all registry values are saved with this option; only the registry parameter values that can be configured using the RDM or the System Menu (and some system parameters) are written and saved to the mkconfig.reg file.

• Start > Programs > System Menu > File > Save.

Figure 3-2 System Menu Main Screen

This option reads the current content of the mkcofig.reg file, allows user changes, then writes them back to the mkcofig.reg file. The window shown in Figure 3-2 reads and displays the current contents of the

Page 49

Configuration

3-3 mkconfig.reg file. Tap an item listed in the left window pane to display current mkconfig.reg file information. Edits are permitted to the current file information in the text boxes that appear in the right pane. Tap File > Save to save changes and write them to the mkconfig.reg file. NOTE

If upgrading the MK1200 OS and a configuration (.reg) file was created using an older OS version, you must create a new .reg file (see Creating a Configuration File on page 4-11). For more information about upgrades, see Appendix F, OS Upgrade Procedures.

Downloading the Configuration File to the MK1200 Before downloading the configuration file (.reg file) to the MK1200 Application folder, rename it mkconfig.reg. In MK1200 Configuration Utility window, select File > Open and select the file, then select File > Save As, rename the file mkconfig.reg, and click Save. Use one of the following methods to download the file to the MK1200:

• Use the RDM to “push” the file to the MK1200(s) (see Downloading the Configuration File to the MK1200 Using the RDM on page 4-13).

• Copy the mkconfig.reg file to the MK1200 Application folder using a USB ActiveSync connection (see Downloading the Configuration File Using ActiveSync on page 3-3).

• Send the file to the MK1200 Application folder using FTP (see the instructions provided with the FTP software) or AirBeam.

• Copy the mkconfig.reg file to a PCMCIA card, then transfer the file into the MK1200 Application folder.

Downloading the Configuration File Using ActiveSync To copy the mkconfig.reg from the host computer to the MK1200 Application folder (My Computer/Application) using ActiveSync: 1.

Connect the MK1200 to the host computer by connecting the USB cable (Symbol p/n 25-64626-01R) to the ActiveSync (RS-485) port on the MK1200, and the other end to a USB port on the host computer.

2.

In ActiveSync on the host computer, click Explore. Windows® Explorer opens the Mobile Device window for the MK1200.

3.

Open a new Windows® Explorer and browse the host computer to locate the file.

4.

Right-click on the file and select Copy.

5.

Right-click in the MK1200 Application folder and select Paste. A prompt requests to overwrite the existing file (if present). NOTE

Use the RDM or System Menu to enable ActiveSync support in the MK1200 if support is disabled.

Page 50

3-4

MK1200 MicroKiosk for CE .NET 4.2 Product Reference Guide

Rebooting the MK1200 After downloading the mkconfig.reg file, perform a remote or local cold boot to apply the new settings.

Remote Boot After loading the configuration file onto the MK1200 using the wired or wireless Ethernet connection, use the RDM to send a command over the network to initiate a remote cold boot of the MK1200. 1.

Select the MK1200 to cold boot from the list box in the Remote Device Manager screen.

2.

From the RDM main toolbar, select Actions > Cold Boot. Allow approximately one minute for the MK1200 to reboot and reconnect, then select View > Refresh to verify the device rebooted successfully.

Local Boot To manually cold boot the MK1200, which enables the settings within the mkconfig.reg file to load, press and hold buttons B and C on the MK1200 (see Figure 1-3 on page 1-5) until the display goes blank (typically 15 seconds), then release the buttons. Alternatively, to cold boot the MK1200, select the reboot option from the System Menu File menu.

Page 51

Configuration

3-5

System Menu Setting Defaults Using the System Menu Use the System Menu to set parameter values locally on the MK1200. See Default Parameters on page 3-6 for these options. The System Menu is identical to the RDM Configuration Utility Window for MK1200 devices, and provides local instead of remote access to the same parameters. The System Menu modifies parameters in the configuration file (mkconfig.reg) on the MK1200. NOTE

Saving the System Menu configuration overwrites mkconfig.reg. Reboot the MK1200 to apply the values. To launch the System Menu, even while an application is running, press the physical buttons A, B, and C simultaneously. Use the virtual keyboard to enter data. To launch the virtual keyboard, press buttons B and C simultaneously.

As with the MK1200 Configuration Utility window, the parameters in the System Menu fall into five categories:

• Configuration file Information • Applications • Communications • System configuration • Update.

Figure 3-3 System Menu Main Screen

Page 52

3-6

MK1200 MicroKiosk for CE .NET 4.2 Product Reference Guide

Default Parameters The default settings that follow apply to both the Remote Device Manager on a host computer and System Menu on the MK1200.

Configuration File Information The first branch of the MK1200 Configuration Utility window and System Menu is Configuration File Information. Use this to track mkconfig.reg version information. Table 3-2 provides descriptions for these parameters. Table 3-2 Configuration File Version Information Parameters

Configuration File Information Parameters

Description

Configuration File Version

Default

Configuration File Version Information

Version

Use the Version parameter to specify the version number of the mkconfig.reg file.

Description

Use the Description parameter to write a detailed description of the location, use, and the changes made on the deployed mkconfig.reg file.

Applications The second branch of the MK1200 Configuration Utility window and System Menu is Applications. Table 3-3 provides descriptions and defaults for these parameters. Table 3-3 Application Default Parameters

Application Parameters

Description

Default

Internet Explorer

Internet Explorer Configuration

Anchor Underline

Specifies whether an anchor or link is underlined or not.

no

Cache Limit

Specifies the cache size for Internet Explorer, in kilobytes.

512 kB (0x200 hex)

Search Page

Specifies the default search page for Internet Explorer.

http://search.msn.com

Secure Protocols

Specifies the security settings configuration for Internet Explorer.

TLS 1.0 disabled, SSL 2.0, SSL3.0 enabled

Smooth Scroll

Check to enable smooth scrolling in Internet Explorer.

Disabled

Start Page

The default home page for Internet Explorer.

file:///windows/MK1200.htm

Play Background Sounds

Check to enable playing of sound files in an html page.

Enabled

Page 53

Configuration

Table 3-3 Application Default Parameters (Continued)

Application Parameters

Description

Default

Kiosk IE

Kiosk IE Configuration

ErrorRecoveryPage

Specifies an error recovery page for Internet Explorer. When an error is detected, the browser is redirected to this page.

\Windows\RetryPage.html

NeedProgressBar

Check to display a progress bar on the left top corner of the Kiosk IE which indicates the progress of downloading a page to the Kiosk IE. Enable this feature when deploying MK1200 devices in a slow network.

Disabled

Scanner Wedge

Scanner Wedge Configuration

Append Enter To Barcode?

Check to add an ENTER to the end of each bar code.

Disabled

Append Tab to Barcode?

Check to add a TAB character to the end of each bar code (and after ENTER, if enabled).

Disabled

Trigger Mode

Specifies whether to constantly trigger the scanner laser or trigger it manually.

Manual Trigger

Scanning Mode

Specifies scanner raster mode.

Omnidirectional - 1D only

Prefix

Specifies text to add to the beginning of a bar code.

None

Suffix

Specifies text to add to the end of bar code, before TAB/ENTER (if enabled).

None

Transmit Code ID

Transmit bar code type identifier.

None

Slide Show

Slide Show Inactivity Application parameters

Background Color

Default screen background color if image is smaller than screen. Format is 0BGR, where the first byte is zero, and the rest are byte values for each color.

7340032 (0x700000 hex)

Display Duration

The duration, in seconds, to display each image before loading the next image. The minimum delay allowed is 2s. If this value is less than 2s SlideShow takes delay as system default of 5s.

5 (0x5 hex)

Image Directory

The directory that contains the images to display.

\Application\Slides

3-7

Page 54

3-8

MK1200 MicroKiosk for CE .NET 4.2 Product Reference Guide

Communications The third branch of the MK1200 Configuration Utility window and System Menu is Communications. Table 3-4 describes these wired Ethernet parameters. To configure DHCP options, see DHCP Configuration on page 4-24, and to specify RF settings for wireless networks see Specifying RF Settings for Wireless Network Connections on page 3-8. Table 3-4 Communication Default Parameters

Communication Parameters Onboard Wired Ethernet

Description

Default

Onboard Wired Ethernet Configuration

Enable DHCP

Check to turn on DHCP Address resolution. When checked, do not set IP Address, Subnet Mask, Gateway, DNS Server(s), or WINS Server(s).

Enabled

IP Address

Sets the IP Address for the Onboard Wired Ethernet adapter.

None

Subnet Mask

Sets the subnet mask for the Onboard Wired Ethernet adapter.

None

Default Gateway

Sets the Default Gateway for the Onboard Wired Ethernet adapter.

None

DHCP Options

Opens DHCP Options dialog (see DHCP Configuration on page 4-24).

None

DHCP Server

Specifies DHCP server. The device contacts the specified server for retrieving IP address and other network parameters. If the DHCP is not specified, device automatically broadcasts for the server for retrieving IP address.

None

DNS Domain

The domain name for the Onboard Wired Ethernet adapter.

None

DNS Server(s)

A list of DNS servers, in the order to query.

None

WINS Server(s)

A list of WINS servers, in the order to query.

None

Specifying RF Settings for Wireless Network Connections To enable a wireless MK1200 to work on an RF network, configure RF settings as defined in Appendix B, RF Network Configuration. Two utilities are available for specifying wireless security:

• Aegis Client (page B-2) • Mobile Companion (page B-3). RF devices shipped with a wireless card include both the Aegis Client and Mobile Companion pre-installed. The default client is Aegis. NOTE

RF settings are not stored within the mkconfig.reg file or entered via the RDM. For details on configuring RF settings, see page B-3.

Page 55

Configuration

3-9

System Configuration The fourth branch of the MK1200 Configuration Utility window and System Menu is System Configuration. Table 3-5 lists these parameters and their descriptions. Also see:

• Device Activity Management (Sleep/Wake-up Functionality) on page 3-17 • Printing on page 3-17 • Configuring User Application(s) on page 3-18. Table 3-5 System Configuration Default Parameters

System Configuration Parameters ActiveSync EnableActiveSync Backlight Brightness Buttons

Description

Default

ActiveSync Configuration When an application is running, ActiveSync is enabled at all times.

Enabled

Backlight Configuration Default display backlight brightness.

Bright (maximum)

Configuration of MK1200 four buttons. See Table 7-6 on page 7-9.

Button A

Button A default

38 (0x26 hex)

Up

Button B

Button B default

40 (0x28 hex) Down

Button C

Button C default

37 (0x25 hex) Left

Button D

Button D default

39 (0x27 hex) Right

Button A and B

Button A and B default

13 (0xd hex)

Button A and C

Button A and C default

194 (0xc2 hex) Shift-Tab

Button B and C

Button B and C default

199 (0xc7 hex) Input Panel

Button A, B, and C

Button A, B, and C default

197 (0xc5 hex) System Menu

Button A and D

Button A and D default

18 (0x12 hex) Alt

Button B and D

Button B and D default

9 (0x9 hex)

Button A, B, and D

Button A, B, and D default

195 (0xc3 hex) Alt-Down

Button C and D

Button C and D default

27 (0x1b hex) Cancel/ESC

Button A, C, and D

Button A, C, and D default

196 (0xc4 hex) Calibration

Button B, C, and D

Button B, C, and D default

8 (0x8 hex)

Button A, B, C, and D

Button A, B, C, and D default

198 (0xc6 hex) Signal Strength

Trigger Time

Button combination trigger time, in milliseconds. Specifies the maximum time between button presses for them to be considered a button combination.

500 (0x1f4hex)

Enter

Tab