Page 47

Programming the LS 1004

Introduction This chapter provides information on how to program the LS 1004 scanner. Before programming the scanner, follow the instructions in the Set-up section of Chapter 1. The default table, shown on the following page, illustrates the default values with which the scanner is shipped. If the default values suit your requirements, scan the SET ALL DEFAULTS barcode. This will set the scanner to the default parameters. Changing the scanner ’s programmable parameters is accomplished by scanning the bar codes provided in this section.

4-3

Page 48

LS 1000 Series Product Reference Guide

The following table lists the defaults for all parameters. If you wish to change any option, scan the appropriate bar code(s)

Table 4-1. Default Table Parameter

Default

Page Number

Set Default Parameter

All Defaults page 4-8

Host Interface Select

RS-232C page 4-8

Power On Beep

Disable page 4-9

Beep after Decode

Enable page 4-9

Beeper Tone

Middle page 4-10

Beeper Volume

High Level page 4-10

Decode Attempt Time

1 second page 4-11

Operating Mode

Low Power page 4-12

Aggressive Scan Mode

Disable page 4-12

Transmit “No Decode” message

No Message page 4-13

Decode Redundancy

Disable page 4-13

Code Types

All page 4-14

Enable/Disable UPC/EAN

Enable page 4-15

Transmit UPC-A Check Digit

Enable page 4-15

Transmit UPC-E Check Digit

Enable page 4-15

Decode UPC Only

Disable page 4-15

Convert UPC-E to UPC-A

Disable page 4-16

EAN Zero Extend

Disable page 4-16

Decode UPC/EAN Supplemental

No Supplemental page 4-17

UPC-E Preamble

System Character page 4-18

UPC-A Preamble

System Character page 4-18

UPC/EAN Security Level

Level 0 page 4-19

UPC/EAN

4-4

Page 49

Programming the LS 1004

Table 4-1. Default Table Parameter

Default

Page Number

Code 128 Enable/Disable Code 128

Enable page 4-20

Send Code 128 Function Character

Disable page 4-20

Enable/Disable Code 39

Enable page 4-21

Code 39 modulo 43 check

Disable page 4-21

Transmit Code 39 Check Digit

Disable page 4-21

Enable/Disable Code 39 Full ASCII

Enable page 4-21

Enable page 4-22

Enable/Disable Code I 2 of 5

Enable page 4-23

Set I 2 of 5 Lengths

14 (length 1) 0 (length 2)

page 4-23

Modulo 10 Check Digit

Disable page 4-25

ITF14/EAN13 Conversion

Disable page 4-25

Enable/Disable Code D 2 of 5

Enable page 4-26

Modulo 10 Check Digit

Disable page 4-26

Set D 2 of 5 Lengths

12 (length 1) 0 (length 2)

page 4-26

Enable/Disable Codabar

Enable page 4-28

CLSI Editing

Disable page 4-28

NOTIS Editing

Disable page 4-28

Code 39

Code 93 Enable/Disable Code 93 I 2 of 5

D 2 of 5

Codabar

4-5

Page 50

LS 1000 Series Product Reference Guide

Table 4-1. Default Table Parameter

Default

Page Number

Data Options Transmit Code ID Character

Disable page 4-29

Prefix

None page 4-30

Suffix

CR/LF page 4-31

Baud Rate

9600 page 4-33

Parity

Even page 4-34

Data Format

7 Data Bits (with Parity)

page 4-35

Stop Bit Select

Two page 4-35

Check Parity of Received Data

Enable page 4-35

Hardware Handshaking

None page 4-36

Software Handshaking

None page 4-37

Intercharacter Delay

0msec page 4-40

RS-232C

4-6