Programming the LS 1004
Introduction This chapter provides information on how to program the LS 1004 scanner. Before programming the scanner, follow the instructions in the Set-up section of Chapter 1. The default table, shown on the following page, illustrates the default values with which the scanner is shipped. If the default values suit your requirements, scan the SET ALL DEFAULTS barcode. This will set the scanner to the default parameters. Changing the scanner ’s programmable parameters is accomplished by scanning the bar codes provided in this section.
4-3
Page 48
LS 1000 Series Product Reference Guide
The following table lists the defaults for all parameters. If you wish to change any option, scan the appropriate bar code(s)
Table 4-1. Default Table Parameter
Default
Page Number
Set Default Parameter
All Defaults page 4-8
Host Interface Select
RS-232C page 4-8
Power On Beep
Disable page 4-9
Beep after Decode
Enable page 4-9
Beeper Tone
Middle page 4-10
Beeper Volume
High Level page 4-10
Decode Attempt Time
1 second page 4-11
Operating Mode
Low Power page 4-12
Aggressive Scan Mode
Disable page 4-12
Transmit “No Decode” message
No Message page 4-13
Decode Redundancy
Disable page 4-13
Code Types
All page 4-14
Enable/Disable UPC/EAN
Enable page 4-15
Transmit UPC-A Check Digit
Enable page 4-15
Transmit UPC-E Check Digit
Enable page 4-15
Decode UPC Only
Disable page 4-15
Convert UPC-E to UPC-A
Disable page 4-16
EAN Zero Extend
Disable page 4-16
Decode UPC/EAN Supplemental
No Supplemental page 4-17
UPC-E Preamble
System Character page 4-18
UPC-A Preamble
System Character page 4-18
UPC/EAN Security Level
Level 0 page 4-19
UPC/EAN
4-4
Page 49
Programming the LS 1004
Table 4-1. Default Table Parameter
Default
Page Number
Code 128 Enable/Disable Code 128
Enable page 4-20
Send Code 128 Function Character
Disable page 4-20
Enable/Disable Code 39
Enable page 4-21
Code 39 modulo 43 check
Disable page 4-21
Transmit Code 39 Check Digit
Disable page 4-21
Enable/Disable Code 39 Full ASCII
Enable page 4-21
Enable page 4-22
Enable/Disable Code I 2 of 5
Enable page 4-23
Set I 2 of 5 Lengths
14 (length 1) 0 (length 2)
page 4-23
Modulo 10 Check Digit
Disable page 4-25
ITF14/EAN13 Conversion
Disable page 4-25
Enable/Disable Code D 2 of 5
Enable page 4-26
Modulo 10 Check Digit
Disable page 4-26
Set D 2 of 5 Lengths
12 (length 1) 0 (length 2)
page 4-26
Enable/Disable Codabar
Enable page 4-28
CLSI Editing
Disable page 4-28
NOTIS Editing
Disable page 4-28
Code 39
Code 93 Enable/Disable Code 93 I 2 of 5
D 2 of 5
Codabar
4-5
Page 50
LS 1000 Series Product Reference Guide
Table 4-1. Default Table Parameter
Default
Page Number
Data Options Transmit Code ID Character
Disable page 4-29
Prefix
None page 4-30
Suffix
CR/LF page 4-31
Baud Rate
9600 page 4-33
Parity
Even page 4-34
Data Format
7 Data Bits (with Parity)
page 4-35
Stop Bit Select
Two page 4-35
Check Parity of Received Data
Enable page 4-35
Hardware Handshaking
None page 4-36
Software Handshaking
None page 4-37
Intercharacter Delay
0msec page 4-40
RS-232C