Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 6 of 13

LS 1000 Series Product Reference Guide: Chapter 3 Maintenance & Specifications, pages 38 to 46

Pages 38 to 46 of 104, from LS 1000 Series Product Reference Guide

The original document is the PDF (1.0 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Symbol LS-1004

Page 38

LS 1000 Series Product Reference Guide

Table 3-1. Technical Specifications (LS 1000) (Continued) Item

Description

Operating Temperature

32° to 104°F

0° to 40°C

Storage Temperature

-40° to 140°F

-40° to 60°C

Humidity

5% to 95% (non-condensing)

Durability

4-ft. drop to concrete 1.2 m

Dimensions Height Length Width

4.8 in. 3.7 in. 2.4 in.

122 mm 93 mm 60 mm

Laser Classifications

CDRH Class II IEC 825 Class 2

Start-Up Time

<50 msec from scan enable

Data Acquisition Time

<110 msec from scan enable

Minimum Element Width

0.005 in

Maximum Element Width

0.020 in

3-10

0.127 mm

Page 39

Maintenance & Specifications

Table 3-2. Technical Specifications (LS 1004) Item

Power Requirements* RS-232C/Synapse Low Power

Description

4.75 to 14.5 VDC (max) 100mA @ 5VDC typical 4.75 to 14 VDC (max) 200 mA @ 5V typical

Decode Capability

The LS 100x can be programmed to decode the following code types: UPC/EAN, Code 39, Code 39 Full ASCII, Code 93, Codabar, Interleaved 2 of 5, Code 128, EAN 128, and Discrete 2 of 5. Set code length(s) for any linear code type. The LS 100x can auto-discriminate between all of the above code types except for Code 39 and Code 39 Full ASCII.

Beeper Operation

User-selectable: Enabled, Disabled., Volume, Tone

Scan Repetition Rate

36 (± 3) scans/sec (bidirectional)

Skew Tolerance

± 65° from normal

Pitch

± 60° from normal

Decode Depth of Field

See Decode Zone

Print Contrast Minimum

25% absolute dark/light differential, measured at 670 nm.

Ambient Light Immunity Artificial Lighting Sunlight

450 ft. candles 8000 ft. candles

4844 lux 86112 lux

3-11

Page 40

LS 1000 Series Product Reference Guide

Table 3-2. Technical Specifications (LS 1004) (Continued) Item

Description

Operating Temperature

32° to 104°F

0° to 40°C

Storage Temperature

-40° to 140°F

-40° to 60°C

Humidity

5% to 95% (non-condensing)

Durability

4-ft. drop to concrete 1.2 m

Dimensions Height Length Width

4.8 in. 3.7 in. 2.4 in.

122 mm 93 mm 60 mm

Laser Classifications

CDRH Class II IEC 825 Class 2

Start-Up Time

<50 msec from scan enable

Data Acquisition Time

<110 msec from scan enable

Minimum Element Width

0.005 in

0.127 mm

Maximum Element Width

0.020 in

5.08 mm

*For direct host power connection, make sure the host terminal supplies sufficient power for the specified operation. Symbol is not responsible for damage to host equipment or system mis-operation due to an insufficient power condition.

3-12

Page 41

Maintenance & Specifications

Table 3-3. Pinouts - LS 1000 Pin

LS 1000

Function

1

VBAT

Power Supply

2

VBAT

Power Supply

3

GND

Ground

4

ENABLE

Scan Enable

5

SOS

Start of Scan

6

TRIGGER*

Trigger Signal

7

DECODE

Successful Decode

8

DBP

Digital Bar Pattern

9

N.C.

Non-Connected

10

N.C.

Non-Connected

* active low

3-13

Page 42

LS 1000 Series Product Reference Guide

Table 3-4. Pinouts - LS 1004 Pin

LS 1004

1

Data

Data Line (for synapse)

2

VBAT

Power Supply

3

GND

Ground

4

RTS

Request to Send (for RS-232C)

5

RXD*

Receive Data Input (for RS-232C)

6

N.C.

Non-Connected (for RS-232C)

7

DTR

Data Terminal Ready (for RS-232C)

8

TXD*

Transmit Data Output (for RS-232C)

9

CTS

Clear to Send (for RS232C)

10

Clock

Clock Line (for Synapse)

* active low

3-14

Function

Page 43

Maintenance & Specifications

Table 3-5. Beeper Indications Standard Use Beeper Sequence

Indication

1 Beep - short high tone

A bar code symbol was decoded (if decode beeper is enabled).

4 Beeps - long low tone

A transmission error has been detected in a scanned symbol. The last data scanned was lost. Scan the last data again.

4 Beeps - short high tone

Low power indication; no further scanning is possible. Change or recharge battery.

3 Beeps - short high tone

Power-up (continuous power mode only)

Parameter Menu Scanning 1 Beep - short high tone

Appropriate menu within the scanning sequence has been read

1 Beep - warble sound

Parameter value entered successfully

2 Beeps - long low tone

Parameter not entered, or incorrect sequence performed. Scan CANCEL and restart the scanning sequence.

3-15

Page 44

LS 1000 Series Product Reference Guide

3-16

Page 45

Chapter 4 Programming The LS 1004 Chapter Contents Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-3 Default Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-4 Scanning Sequence. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-7 Scanning Sequence Example . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-7 Errors While Scanning. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-7 Parameter Descriptions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-8 Set Parameter Defaults . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-8 Host Interface Select . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-8 Power On Beep Enable/Disable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-9 Beeper after Decode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-9 Beeper Tone . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-10 Beeper Volume . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-10 Decode Attempt Time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-11 Operating Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-12 Aggressive Scan Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-12 Transmit “No Decode” Message . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-13 Decode Redundancy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-13 Code Types . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-14 UPC/EAN. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-15 Enable/Disable UPC/EAN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-15 Transmit UPC-E/UPC-A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-15 Decode UPC Only (Not EAN) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-15 Convert UPC-E to UPC-A. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-16 EAN Zero Extend. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-16 Decode UPC/EAN Supplemental. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-17 UPC A and E Preamble(s). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-18 UPC/EAN Security Level. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-19 Code 128 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-20 Enable/Disable Code 128 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-20 Send CODE 128 Function Character . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-20 Code 39 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-21 Enable/Disable Code 39 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-21 CODE 39 Modulo 43 Check . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-21 Transmit CODE 39 Check Digit. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-21 Enable/Disable Code 39 Full ASCII . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-21

4-1

Page 46

LS 1000 Series Product Reference Guide

Code 93 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-22 Enable/Disable Code 93 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-22 Interleaved 2 of 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-23 Enable/Disable Code I 2 of 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-23 Fixed Lengths for Code I 2 of 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-23 Fixed Lengths for Code 2 of 5 (cont’d) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-24 I 2 of 5 Modulo 10 Check . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-25 ITF14/EAN13 Conversion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-25 Discrete 2 of 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-26 Enable/Disable D 2 of 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-26 D 2 of 5 Modulo 10 Check. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-26 Fixed Lengths for Code 2 of 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-26 Fixed Lengths for Code 2 of 5 (cont’d) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-27 Codabar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-28 Enable/Disable Codabar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-28 CLSI Editing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-28 NOTIS Editing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-28 Data Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-29 Transmit Code ID Character . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-29 Prefix . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-30 Suffix . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-31 Prefix/Suffix Values . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-32 RS-232C . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-33 Baud Rate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-33 Parity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-34 Data Format . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-35 Stop Bit Select . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-35 Check Parity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-35 Hardware Handshaking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-36 Software Handshaking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-37 Hardware and Software Handshaking Sequence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-39 Communications Delays and Time-Outs (Intercharacter Delay) . . . . . . . . . . . . . . . . 4-40

4-2