CRD 1500 Modem/Charging Cradle Programmer's Guide: Chapter 2 S-Registers, pages 62 to 70
Pages 62 to 70 of 84, from CRD 1500 Modem/Charging Cradle Programmer's Guide
The original document is the PDF (717 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Symbol CRD1500-1000
Page 62
CRD 1500 Modem/Charging Cradle Programmer’s Guide
S16, General Bit Mapped Test Options Status Description Indicates the test in progress status. Default: 0 Bit 0
Local analog loopback 0 = Disabled (default) 1 = Enabled (&T1)
Bit 1
Not used
Bit 2
Local digital loopback 0 = Disabled (default) 1 = Enabled (&T3)
Bit 3
Remote digital loopback (RDL) status 0 = Modem not in RDL (default) 1 = RDL in progress
Bit 4
RDL requested (AT&T6) 0 = RDL not requested (default) 1 = RDL requested (&T6)
Bit 5
RDL with self test 0 = Disabled (default) 1 = Enabled (&T7)
Bit 6
Local analog loopback (LAL) with self test 0 = Disabled (default) 1 = Enabled (&T8)
Bit 7
Not used
S17, Reserved
2-10
Page 63
S-Registers
S18, Test Timer Description Sets the length of time, in seconds, the modem conducts a test (commanded by &Tn) before returning to the command mode. If this register value is zero, the test does not automatically terminate; you must issue an &T0 or H command from the command mode. When S18 is non-zero, the modem returns the OK message upon test termination. Range:
0-255 seconds
Default: 0
S19, AutoSync Bit Mapped Options Description Defines the options for AutoSync operation (see &Qn, Sync/Async Mode on page 1-20). S19 must be set to the desired value before &Q4 is issued. Default: 0 Bit 0
Reserved
Bit 1
BSC/HDLC format select 0 = BSC selected (default) 1 = HDLC selected
Bit 2
Address detection enable/disable 0 = Disabled (default) 1 = Enabled
Bit 3
NRZI/NZI coding select 0 = NRZI (default) 1 = NZI
Bit 4
Idle indicator select 0 = Mark idle (default) 1 = Flag or sync idle
Bits 5-7 Reserved
2-11
Page 64
CRD 1500 Modem/Charging Cradle Programmer’s Guide
S20, AutoSync HDLC Address or BSC Sync Character Description Defines the HDLC address (S19 bit 1 = 1) or BSC Sync Character (S19 bit 1 = 0) for AutoSync operation (see &Qn, Sync/Async Mode on page 1-20). Set S20 to the desired value before issuing &Q4. Range:
0-255
Default: 0
S21, V.24/General Bit Mapped Options Status Description Indicates the status of command options. Default: 52 (34h) (00110100b) Bit 0
Set by &Jn command but ignored otherwise. 0 = &J0 (default) 1 = &J1
Bit 1
Reserved
Bit 2
CTS behavior (&Rn) 0 = CTS tracks RTS (&R0) 1 = CTS always on (&R1) (default)
Bits 3-4 DTR behavior (&Dn) 0 = &D0 selected 1 = &D1 selected 2 = &D2 selected (default) 3 = &D3 selected Bit 5
RLSD (DCD) behavior (&Cn) 0 = &C0 selected 1 = &C1 selected (default)
Bit 6
2-12
DSR behavior (&Sn)
Page 65
S-Registers
0 = &S0 selected (default) 1 = &S1 selected Bit 7
Long space disconnect (Yn) 0 = Y0 (default) 1 = Y1
S22, Speaker/Results Bit Mapped Options Status Description Indicates the status of command options. Default: 117 (75h) (01110101b) Bits 0-3 Reserved Bits 4-6 Limit result codes (Xn) 0 = X0 4 = X1 5 = X2 6 = X3 7 = X4 (default) Bit 7
Reserved
2-13
Page 66
CRD 1500 Modem/Charging Cradle Programmer’s Guide
S23, General Bit Mapped Options Status Description Indicates the status of command options. Default: 62 (3Dh) (00111110b) Bit 0
Grant RDL 0 = RDL not allowed (&T5) (default) 1 = RDL allowed (&T4)
Bits 1-3 DTE Rate 0 = 0 - 300 bps 1 = 600 bps 2 = 1200 bps 3 = 2400 bps 4 = 4800 bps 5 = 9600 bps 6 = 19200 bps 7 = 38400 bps or higher (default) Bits 4-5 Assumed DTE parity 0 = even 1 = not used 2 = odd 3 = none (default) Bits 6-7 Guard tone (&Gn) 0 = None (&G0) (default) 1 = None (&G1) 2 = 1800 Hz (&G2)
2-14
Page 67
S-Registers
S24, Sleep Inactivity Timer Description Sets the length of time, in seconds, the modem operates in normal mode with no detected telephone line or DTE line activity before entering low-power sleep mode. The timer is reset upon any DTE line or telephone line activity. If the S24 value is zero, neither DTE line nor telephone inactivity will cause the modem to enter the sleep mode. Range:
0-255 seconds
Default: 0
S25, Delay To DTR Description Sets the length of time the modem ignores DTR for taking the action specified by &Dn. Its units are seconds for one hundredths of a second. Range:
0-255 (1 second for synchronous modes 1; 0.01 second otherwise)
Default: 5
S26, RTS to CTS Delay Description Sets the time delay, in hundredths of a second, before the modem turns CTS ON after detecting an OFF-to-ON transition on RTS when &R0 is commanded. Range:
0-255 hundredths of a second
Default: 1
2-15
Page 68
CRD 1500 Modem/Charging Cradle Programmer’s Guide
S27, Bit Mapped Options Status Description Indicates the status of command options. Default: 73 (49h) (01001001b) Bits 0,1,3 Synchronous/asynchronous selection (&Mn/&Qn) 3 0 0 0 0 1 1 1 Bit 2
1 0 0 1 1 0 0 1
0 0 1 0 1 0 1 0
= = = = = = =
&M0 or &Q0 &M1 or &Q1 &M2 or &Q2 &M3 or &Q3 &Q4 &Q5 (default) &Q6
Leased line control (&Ln) 0 =Dial up line (&L0) (default)
Bits 4-5
Internal clock select (&Xn) 0 = Internal clock (&X0) (default) 1 = External clock (&X1) 2 = Slave clock (&X2)
Bit 6
CCITT/Bell mode select (Bn) 0 = CCITT mode (B0) 1 = Bell mode (B1) (default)
Bit 7
Reserved
S28, Bit Mapped Options Status Default: 0 Bits 0-1 Reserved Bit 2
Reserved (always 0).
Bits 3-4 Pulse dialing (&Pn)
2-16
Page 69
S-Registers
0 = 39%-61% make/break ratio at 10 pulses per second (&P0) (default) 1 = 33%-67% make/break ratio at 10 pulses per second (&P1) 2 = 39%-61% make/break ratio at 20 pulses per second (&P2) 3 = 33%-67% make/break ratio at 20 pulses per second (&P3) Bit 5-7 Reserved
S30, Disconnect Inactivity Timer Description Sets the length of time, in tens of seconds, the modem remains online before disconnecting when no data is sent or received. In error-correction mode, any data transmitted or received resets the timer. In other modes, any data transmitted resets the timer. The timer is inoperative in synchronous mode. Range:
0-255 tens of seconds (0-2550 seconds)
Default: 0 (disabled)
S31, Bit Mapped Options Status Default: 194 (C2h) (11000010b) Bit 0
Single line connect message enable/disable (\Vn) 0 = Messages controlled by S95, Wn and Vn (\V0) (default) 1 = Single line connect message (\V1)
Bit 1
Auto line speed detection (Nn) 0 = Disabled (N0) 1 = Enabled (N1) (default)
Bits 2-3 Error correction progress messages (Wn) 0 = DTE speed only (W0) (default) 1 = Full reporting (W1) 2 = DCE speed only (W2) Bits 4-5 Caller ID (#CID) 0 = Caller ID disabled (#CID=0) (default) 1 = Short (formatted) Caller ID enabled (#CID=1) 2 = Long (unformatted) Caller ID enabled (#CID=2) 2-17
Page 70
CRD 1500 Modem/Charging Cradle Programmer’s Guide
Bits 6-7 Reserved (default = 11b)
S32, XON Character Description Sets the value of the XON character. Range:
0-255, ASCII decimal
Default: 17 (11h)
S33, XOFF Character Sets the value of the XOFF character. Range: 0-255, ASCII decimal Default: 19 (13h)
S34-S35, Reserved S36, LAPM Failure Control Default: 7 (00000111b) Bits 0-2 This value indicates what should happen upon a LAPM failure. These fallback options are initiated immediately upon connection if S48=128. If an invalid number is entered, the number is accepted into the register, but S36 behaves as if the default value was entered. 0 = Modem disconnects. 1 = Modem stays on-line and a Direct mode connection is established. 2 = Reserved. 3 = Modem stays on-line and a Normal mode connection is established. 4 = An MNP connection is attempted and if it fails, the modem disconnects. 5 = An MNP connection is attempted and if it fails, a Direct mode connection is established. 6 = Reserved. 7 = An MNP connection is attempted and if it fails, a Normal mode connection is established (default). Bits 3-7 Reserved
2-18